Liebert Rack Enclosure With Integrated Liquid Cooling XDK-W user manual

User manual for the device Liebert Rack Enclosure With Integrated Liquid Cooling XDK-W

Device: Liebert Rack Enclosure With Integrated Liquid Cooling XDK-W
Category: Network Card
Manufacturer: Liebert
Size: 2.74 MB
Added : 6/8/2013
Number of pages: 88
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Liebert Rack Enclosure With Integrated Liquid Cooling XDK-W. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Liebert Rack Enclosure With Integrated Liquid Cooling XDK-W.

For your convenience

If looking through the Liebert Rack Enclosure With Integrated Liquid Cooling XDK-W user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Liebert Rack Enclosure With Integrated Liquid Cooling XDK-W on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Liebert Rack Enclosure With Integrated Liquid Cooling XDK-W to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Liebert Rack Enclosure With Integrated Liquid Cooling XDK-W User manual - Online PDF
Advertisement
« Page 1 of 88 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Liebert Rack Enclosure With Integrated Liquid Cooling XDK-W but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Liebert Rack Enclosure With Integrated Liquid Cooling XDK-W. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Precision Cooling
For Business-Critical Continuity™
® ™
Liebert XDK-W Rack Enclosure With Integrated Liquid Cooling
User Manual–25kW, 50 and 60Hz

Summary of the content on the page No. 2

Summary of the content on the page No. 3

CoolTherm Manual / Bedienungsanleitung Manual CoolTherm Server Cabinet with integrated liquid cooling Effective cooling capacity 12 - 25 / 35 KW Bedienungsanleitung CoolTherm Schaltschrank mit integrierter Flüssigkeitskühlung Nutzkühlleistung 12 -25 / 35 KW (ab Seite 42) date / Datum issue / Ausgabe

Summary of the content on the page No. 4

CoolTherm Manual / Bedienungsanleitung Contents page 0. Abstract ......................................................................................................................................... 3 1. Safety.......................................................................................................................

Summary of the content on the page No. 5

CoolTherm Manual / Bedienungsanleitung 0. Abstract The CoolTherm platform provides the dissipation of heat loads from 10 up to 22 / 35 kW. The server rack is closed to the installation area, that means no heat load will dissipate to the environment. (see also chapter 2.) The cooling is provided by a closed cooling system via an air- to-water h

Summary of the content on the page No. 6

CoolTherm Manual / Bedienungsanleitung Important note, information 1.2 Safety instructions Our engineers will provide comprehensive support on how to install the CoolTherm. Extensive material, function and quality checks ensure that you fully benefit from product functions and a long service life. Nevertheless, th

Summary of the content on the page No. 7

CoolTherm Manual / Bedienungsanleitung During all work on and with the unit, observe: • The related applicable regulations (e. g. VDE regulations or other applicable national regulations) • The applicable accident prevention instructions (BGV) • The applicable rules • The applicable laws on the protection of the environment Only operate

Summary of the content on the page No. 8

WARM WARM CoolTherm Manual / Bedienungsanleitung Temperature spread, water: 6K Use of anti-freeze in the chilled water: upon request Water connection: from below Condensed water connection: from below Nominal voltage at cooling capacity: 12 KW, 17 KW, 25 KW 200V to 264V / 50Hz / 60 Hz Max. operat

Summary of the content on the page No. 9

CoolTherm Manual / Bedienungsanleitung 3.2 Principle of operation of cooling Air that has been heated by the servers (to 35°C/95°F, e.g.) is fed to a specially designed air/water heat exchanger using high-performance fans. There the air is cooled to approx. 20-25°C / 68-77°F, and fed to the front of the server. The server fans can draw in t

Summary of the content on the page No. 10

CoolTherm Manual / Bedienungsanleitung If the front door is opened, it is not necessary to open the rear door. 3.3 Dimensions 1 5 4 3 2 1 Multifunction door (rear) with embedded redundant fans, air duct and sealing 2 Heat exchanger with condensate tray, condensate connection 3 recirculation de

Summary of the content on the page No. 11

CoolTherm Manual / Bedienungsanleitung legend: 1 sealed cable cutout 2 cutout for chilled water pipes 3 cable entry (network cable) 4 cutouts for condensed water rear side standard dimension front side cover dimensions with cable entries 12- 17 - 25 / 35 kW plan view) Cable and pipe openings are to be sea

Summary of the content on the page No. 12

CoolTherm Manual / Bedienungsanleitung Dimensions bottom plate / cut outs / connections 12- 17 - 25 / 35 kW CoolTherm 01_998_330_0_k page / Seite 10/83

Summary of the content on the page No. 13

CoolTherm Manual / Bedienungsanleitung Useable space for server CoolTherm 01_998_330_0_k page / Seite 11/83

Summary of the content on the page No. 14

CoolTherm Manual / Bedienungsanleitung 3.4 Technical data Housing material: Aluminium sheet, sheet steel, galvanized and coated Operating Temperature range: 10 °C to 35 °C / 50°F to 95°F abs. atmospheric humidity: 8g / kg maximum Air outlet to heat exchanger: 20 to 25°C / 68 to 77°F according to ASHRAE Temperature differenc

Summary of the content on the page No. 15

CoolTherm Manual / Bedienungsanleitung Data overview CoolTherm Table A General data Spread chilled water: 12 / 18°C (nominal conditions) Maximum operation pressure heat exchanger: 10 bar Air temperature to server: 22°C Maximum absolute humidity on site : 8g/kg Connection heat exchanger: 1“ female threat Colour code for standard

Summary of the content on the page No. 16

CoolTherm Manual / Bedienungsanleitung Data overview CoolTherm Table B (Hydraulic Data) effective total cooling total cooling water water flow pressure water water cooling capacity capacity content rate loss temperature temperature capacity (at normal (at full speed cabinet rise rise operation) operation / (at normal (at full speed eme

Summary of the content on the page No. 17

CoolTherm Manual / Bedienungsanleitung 3.5 Control The server cabinet temperature is controlled by the fan control board VR 2.2. A air temperature sensor continuously measures the temperature of the server cabinet (server feed air). The air circulation flow rate is controlled by the fan speed according to the current thermal load. At temper

Summary of the content on the page No. 18

CoolTherm Manual / Bedienungsanleitung valve actuator Three way valve Bypass (flow direction) CoolTherm Heat Exchanger (rear view) The programming of the control is factory preset and password protected. The failure of the temperature sensor or one of the fans set an alarm using a potential free contact. Following alarms can be a

Summary of the content on the page No. 19

CoolTherm Manual / Bedienungsanleitung Start at 16°C air inlet temperature three- way valve control characteristic (factory setting) 4. Storage and transportation • Cover open pallets with tarpaulins and protect the components from soiling (e. g. sand, rain, dust, etc.). • Keep storage temperatures between –30 °C and +50 °C / -22

Summary of the content on the page No. 20

CoolTherm Manual / Bedienungsanleitung Safety instruction for crane transport: < 680 kg Eyebolts M 12 according to standard DIN 580! > 680 kg > 1000 kg CoolTherm 01_998_330_0_k page / Seite 18/83


Alternative user manuals
# User manual Category Download
1 Liebert ECA2 User manual Network Card 2
2 Liebert Challenger ITR User manual Network Card 1
3 Liebert EM User manual Network Card 2
4 Liebert Extreme Density Chiller XDC User manual Network Card 1
5 Liebert Distribution Monitoring LDM User manual Network Card 0
6 Liebert IntelliSlot OC-485 User manual Network Card 3
7 Liebert Extender/Adapter User manual Network Card 1
8 Liebert Cooling Modules XDH User manual Network Card 0
9 Liebert Intellislot Web/485 User manual Network Card 11
10 Liebert Integrated Cabinet Solutions User manual Network Card 0
11 Liebert FS-8704-02 User manual Network Card 0
12 Liebert 485 User manual Network Card 1
13 Liebert IS-WEBRT3 User manual Network Card 3
14 Liebert Cooling System XDV User manual Network Card 0
15 Liebert Network Device EIA-485/232 User manual Network Card 0
16 Sony BTA-NW1A User manual Network Card 2
17 Sony BKMW-E3000 User manual Network Card 2
18 Sony AC-SQ950D User manual Network Card 0
19 Sony BBV RX100 User manual Network Card 3
20 Sony CLIE A-AVZ-100-11 User manual Network Card 1