Liebert Overhead Precision Cooling and Humidity Control Mini-Mate2 user manual

User manual for the device Liebert Overhead Precision Cooling and Humidity Control Mini-Mate2

Device: Liebert Overhead Precision Cooling and Humidity Control Mini-Mate2
Category: Network Card
Manufacturer: Liebert
Size: 1.31 MB
Added : 6/8/2013
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Liebert Overhead Precision Cooling and Humidity Control Mini-Mate2. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Liebert Overhead Precision Cooling and Humidity Control Mini-Mate2.

For your convenience

If looking through the Liebert Overhead Precision Cooling and Humidity Control Mini-Mate2 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Liebert Overhead Precision Cooling and Humidity Control Mini-Mate2 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Liebert Overhead Precision Cooling and Humidity Control Mini-Mate2 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Liebert Overhead Precision Cooling and Humidity Control Mini-Mate2 User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Liebert Overhead Precision Cooling and Humidity Control Mini-Mate2 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Liebert Overhead Precision Cooling and Humidity Control Mini-Mate2. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Precision Cooling

For Business-Critical Continuity

Liebert Mini-Mate2 1 To 8 Tons
Overhead Precision Cooling And Humidity Control

Summary of the content on the page No. 2

The Solution For Your Cooling Needs May Be Right Above You When the need calls for precision cooling and humidity Liebert Mini-Mate2 Offers: control, but your floor space says otherwise, the Liebert Reliability: ™ Mini-Mate2 can provide the overhead answer. This High Sensible Cooling Capacity. Unlike “comfort” air conditioners, Liebert systems are designed for the flexible, space-saving system is the ideal solution for cooling requirements of electronic equipment – 80% of small areas where sp

Summary of the content on the page No. 3

Liebert Monitoring Solutions: When You Need To Know You will find a full-range of monitoring and control systems, communications modules designed to interface Liebert equipment with Low Total Cost Of Ownership: a variety of building management systems, plus stand-alone monitoring, High-Efficiency Compressor. The rotary or scroll control and leak detection devices. compressors are both energy-efficient and rugged, to ensure continuous operation. Local And Remote Advanced Monitoring ® Monit

Summary of the content on the page No. 4

The Right Size To Fit Your Space And Application With more than 10,000 possible configurations, there is a LiebertMini-Mate2 system available to fit the needs of many room cooling or spot cooling requirements. Liebert Mini-Mate2™ Product A Variety Of Options Help You Meet Features Include: Numerous Applications: Available in 1,1.5, 2, 3, 5 & 8 ton capacities Grille (1-1.5 tons) or Plenum (2-3 tons) that fits 2’x4’ (3-stage cooling on 8-ton) ceiling grid for direct supply & return air distrib

Summary of the content on the page No. 5

5-Ton Ducted Liebert Mini-Mate2 Capacity (Tons) Product Option Availability 1 1.5 2 3 5 8 Chilled Water (rated @ 300 psi static pressure) • • • Chilled Water (rated @ 400 psi static pressure) •• Self-Contained Air-Cooled • • Self-Contained Water/Glycol-Cooled • • Split System Air-Cooled w/Centrifugal Indoor Condensing Unit • • • • Split System Air-Cooled w/Outdoor High Ambient Prop Fan Condensing Unit • • • Split System Air-Cooled w/Outdoor Prop Fan Condensing Unit • • • • • • Split System Ai

Summary of the content on the page No. 6

1 1 And 1- /2 Ton Systems Air-Cooled Water/Glycol Chilled-Water Expansion Tank Drycooler Pump Self-Contained Air-Cooled with Grille Self-Contained Glycol System with Grille Chilled-Water with Grille Expansion Tank Drycooler Pump Self-Contained Glycol System Ducted Chilled-Water Ducted Self-Contained Air-Cooled Ducted Optional Filter Box, Duct Connection Available Optional Filter Box, Duct Connection Available Optional Filter Box, Duct Connection Available Cooling Tower Prop Fan Condensing Evap

Summary of the content on the page No. 7

Specifications 1 1 And 1- /2 Ton Systems 60 HZ 50 HZ AIR COOLED SYSTEM with Outdoor Condensing Unit with Centrifugal Condensing Unit with Outdoor Condensing Unit with Centrifugal Condensing Unit Split System Self-Contained Split System Self-Contained 1 Ton 1.5 Tons 1 Ton 1.5 Tons 1 Ton 1.5 Tons 1 Ton 1.5 Tons Evaporator MMD12E MMD18E MMD12A MMD18A MMD11E MMD17E MMD11A MMD17A Condensing Unit PFH014A PFH020A MM2CF MM2CF PFH013A PFH019A MM2CF MM2CF Net Capacity Data*BTUH (kW) High Fan

Summary of the content on the page No. 8

2 And 3 Ton Systems Air-Cooled Water/Glycol Chilled-Water Utilizes Split System Evaporator Utilizes Split System Evaporator Centrifugal Fan E Expansion Tank Condensing Unit Water/Glycol Condensing Unit Evaporator Evaporator E Drycooler Pump Remote Air-Cooled Condensing Unit Remote Water/Glycol-Condensing Unit Chilled-Water Supply & Return Air Plenum Supply & Return Air Plenum Supply & Return Plenum Centrifugal Fan Condensing Unit Expansion Tank Evaporator C Water/Glycol Condensing Unit E

Summary of the content on the page No. 9

Specifications 2 And 3 Ton Split Systems 60 HZ 50 HZ AIR COOLED SYSTEM with Outdoor Condensing Unit with Centrifugal Condensing Unit with Outdoor Condensing Unit with Centrifugal Condensing Unit 2 Tons 3 Tons 2 Tons 3 Tons 2 Tons 3 Tons 2 Tons 3 Tons Evaporator MMD24E MMD36E MMD24E MMD36E MMD23E MMD35E MMD23E MMD35E Condensing Unit PFH027A PFH037A MCD24A MCD36A PFH026A PFH036A MCD23A MCD35A Net Capacity Data*BTUH (kW) High Fan Speed 80 F (26.7 C) DB Total 25,600 (7.5) 36,900 (10.8)

Summary of the content on the page No. 10

5 And 8 Ton Systems Air-Cooled Water/Glycol Chilled-Water Utilizes Split System Evaporator Utilizes Split System Evaporator Cooling Tower Evaporator Evaporator Evaporator Centrifugal Fan Water/Glycol- Condensing Unit Condensing Unit Indoor Air-Cooled Condensing Unit Remote Water/Glycol-Condensing Unit Chilled-Water Coil Supply & Return Air Ducted Supply & Return Air Ducted Supply & Return Air Ducted Optional Filter Box/Duct Connection Available Optional Filter Box/Duct Connection Available Op

Summary of the content on the page No. 11

Specifications 5 And 8 Ton Split Systems 60 Hz 50 Hz AIR COOLED SYSTEM w/Outdoor Condensing Unit w/Centrifugal Condensing Unit w/Outdoor Condensing Unit w/Centrifugal Condensing Unit 5 Tons 5 Tons 5 Tons 5 Tons Evaporator MMD60E MMD60E MMD59E MMD59E Condensing Unit PFH067A MCD65A PFH066A MCD64A Net Capacity Data*-BTUH (kW) 80 F (26.7 C) DB Total 65,000 (19.0) 66,200 (19.4) 65,400 (19.2) 65,500 (19.2) 50% RH Sensible 54,400 (15.9) 54,800 (16.1) 54,800 (16.1) 54,800 (16.1) 75 F (23.9 C) DB To

Summary of the content on the page No. 12

Ensuring The High Availability Of Mission-Critical Data And Applications. Liebert Corporation Emerson Network Power, the global leader in enabling business-critical continuity, 1050 Dearborn Drive ensures network resiliency and adaptability through a family of technologies — P.O. Box 29186 Columbus, Ohio 43229 including Liebert power and cooling technologies — that protect and support 800 877 9222 Phone (U.S. & Canada Only) business-critical systems. Liebert solutions employ an adaptive arch


Alternative user manuals
# User manual Category Download
1 Liebert ECA2 User manual Network Card 2
2 Liebert Challenger ITR User manual Network Card 1
3 Liebert EM User manual Network Card 2
4 Liebert Extreme Density Chiller XDC User manual Network Card 1
5 Liebert Distribution Monitoring LDM User manual Network Card 0
6 Liebert IntelliSlot OC-485 User manual Network Card 3
7 Liebert Extender/Adapter User manual Network Card 1
8 Liebert Cooling Modules XDH User manual Network Card 0
9 Liebert Intellislot Web/485 User manual Network Card 11
10 Liebert Integrated Cabinet Solutions User manual Network Card 0
11 Liebert FS-8704-02 User manual Network Card 0
12 Liebert 485 User manual Network Card 1
13 Liebert IS-WEBRT3 User manual Network Card 3
14 Liebert Cooling System XDV User manual Network Card 0
15 Liebert Network Device EIA-485/232 User manual Network Card 0
16 Sony BTA-NW1A User manual Network Card 2
17 Sony BKMW-E3000 User manual Network Card 2
18 Sony AC-SQ950D User manual Network Card 0
19 Sony BBV RX100 User manual Network Card 3
20 Sony CLIE A-AVZ-100-11 User manual Network Card 1