KTI Networks KCD-400 Series user manual

User manual for the device KTI Networks KCD-400 Series

Device: KTI Networks KCD-400 Series
Category: Network Card
Manufacturer: KTI Networks
Size: 1.46 MB
Added : 12/2/2013
Number of pages: 26
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for KTI Networks KCD-400 Series. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with KTI Networks KCD-400 Series.

For your convenience

If looking through the KTI Networks KCD-400 Series user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual KTI Networks KCD-400 Series on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual KTI Networks KCD-400 Series to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
KTI Networks KCD-400 Series User manual - Online PDF
Advertisement
« Page 1 of 26 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual KTI Networks KCD-400 Series but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to KTI Networks KCD-400 Series. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INDUSTRIAL
1000BASE-T TO 1000BASE-X
MEDIA CONVERTERS
KCD-400 Series
Installation Guide
DOC.060227-KCD-400
-1-

Summary of the content on the page No. 2

(C) 2005 KTI Networks Inc. All rights reserved. No part of this documen- tation may be reproduced in any form or by any means or used to make any directive work (such as translation or transformation) without per- mission from KTI Networks Inc. KTI Networks Inc. reserves the right to revise this documentation and to make changes in content from time to time without obligation on the part of KTI Networks Inc. to provide notification of such revision or change. For more information, contact: Unite

Summary of the content on the page No. 3

The information contained in this document is subject to change without prior notice. Copyright (C) All Rights Reserved. TRADEMARKS Ethernet is a registered trademark of Xerox Corp. FCC NOTICE This device complies with Class B Part 15 the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received including the interference that may cause. CE NOTICE Marking by the symbol indicate

Summary of the content on the page No. 4

Table of Contents 1. Introduction ......................................................... 5 1.1 Features ........................................................................................ 6 1.2 Specifications ................................................................................ 7 1.3 Special Functions.........................................................................11 2. Installation ......................................................... 13 2.1 Unpacking ............

Summary of the content on the page No. 5

1. Introduction The industrial 1000BASE-T to 1000BASE-X media converter series pro- vides industrial strength Ethernet copper-to-fiber media conversion, allow- ing for 1000Base-T-to-1000Base-X over multi-mode or optional single- mode fiber optical media. For industrial environment, the converters are designed with the follow- ing enhanced features exceeding that of commercial media converters:  High and wide operating Temperature  Wide operating voltage range for DC power input  Power input i

Summary of the content on the page No. 6

1.1 Features  Gigabit copper to fiber conversion: 1000Base-T-to-1000Base-SX/LX over multimode or single-mode fiber  SFP design : For flexibility, an SFP (Mini-GBIC) connector is provided for the fiber port to accommodate any type of SFP fiber transceiver when needed.  Support full wire speed copper to fiber conversion  Auto MDI/MDI-X detection function on the copper port  Auto-negotiation support  Plug and play : no configuration settings is required  Link Fault Pass Through : this funct

Summary of the content on the page No. 7

1.2 Specifications This figure shows the important components of the converter: -7-

Summary of the content on the page No. 8

Twisted-Pair Interface (Copper Port) Connector Shielded RJ-45 Signal Compliance IEEE 802.3ab 1000BASE-T std. Pin Assignments Auto MDI/MDI-X detection Data Speed 1000Mbps Duplex Mode Half-duplex or Full-duplex Configuration Auto-negotiation support Cable Types Category 5 or higher UTP Link Distance Up to 100 meters Fiber Optic Interface (Fiber Port) Signal Compliance IEEE 802.3z 1000BASE-SX/LX std. Connector SFP for pluggable fiber transceiver Data Speed 1000Mbps Duplex Mode Full duplex Cable Typ

Summary of the content on the page No. 9

DC Power Interface Interface Screw-type terminal block 1. Two pairs for power wire cascading 2. One pair for power failure relay output DC Jack (-D6.3mm/+D2.0mm) Operating Input Voltages +7V ~ +30V(+5%) Power consumption 2.25W @+7.5VDC input 2.3W @+24VDC input 2.5W @+30VDC input Basic Information Conversion Full wire speed 1000Mbps - 1,488,00pps at 64-byte packets Packet Types Transparent and no modification for - IEEE 802.3 standard packets - IEEE 802.1Q VLAN tagged packets Packet Length No

Summary of the content on the page No. 10

Certificate FCC Part 15 Class B CE/EMC EMI EN50081-1 Class B EMS EN55024 CE/LVD Safety EN 60950 EN 50081-1/1992 : EN55022:1994/A1:1995/A2:1997 EN61000-3-2:2000 EN61000-3-3:1995/A1:2001 EN 55024:1998/A1:2001 IEC 61000-4-2:1995 ESD Test IEC 61000-4-3:1995 RS Test IEC 61000-4-4:1995 EFT/BURST Test IEC 61000-4-5:1995 Surge Test IEC 61000-4-6:1996 CS Test IEC 61000-4-8:1993 Magnetic Field IEC 61000-4-11:1994 Volatge Int. Dips -10-

Summary of the content on the page No. 11

1.3 Special Functions Auto MDI/MDI-X Function This function allows the copper port to auto-detect the twisted-pair sig- nals and adapts itself to form a valid MDI to MDI-X connection with the remote connected device automatically. Link Fault Pass Through Function When a link fault is detected on the copper port, the device will force a link down on the fiber port immediately. Similarly, a link fault detected on the fiber port will also force a link down on the copper port. As illustrated in the

Summary of the content on the page No. 12

Far End Fault Function The fiber port is facilitated with this function. When the fiber port detects a link failure on its receiving circuitry, it will send out an FEFI (Far End Fault Indication) signal to the remote connected device to indicate a remote fault is detected. It also is capable to receive FEFI signal sent from the remote link partner if the link partner detected a receiving fault. Upon receiving an FEFI signal, it indicates a link failure occurred on the transmitting path. This fun

Summary of the content on the page No. 13

2. Installation 2.1 Unpacking Check that the following components have been included:  Information CD  The Media Converter unit  DIN-rail mounting bracket If any item is found missing or damaged, please contact your local reseller for replacement. The following are available optional accessories:  Panel Mounting Bracket The bracket is used for mounting the converter on a panel surface.  Commercial-rated AC power adapters: - Rated AC120V/60Hz DC7.5V 1A - Rated AC230V/50Hz DC7.5V 1A - Rated A

Summary of the content on the page No. 14

2.2 Safety Cautions To reduce the risk of bodily injury, electrical shock, fire, and damage to the equipment, observe the following precautions.  Do not service any product except as explained in your system documentation.  Opening or removing covers may expose you to electrical shock. Only a trained service technician should service components inside these compartments.  If any of the following conditions occur, unplug the product from the electrical outlet and replace the part or contact y

Summary of the content on the page No. 15

2.3 DIN-Rail Mounting In the product package, a DIN-rail bracket is installed on the device for mounting the converter in a industrial DIN-rail enclosure. The steps to mount the device onto a DIN rail are: 1. Install the mounting bracket onto the device unit as shown below: 2. Attach bracket to the lower edge of the DIN rail and push the unit upward a little bit until the bracket can clamp on the upper edge of the DIN rail. 3. Clamp the unit to the DIN rail and make sure it is mounted securely.

Summary of the content on the page No. 16

The final mechanical dimensions after installing DIN rail mounting bracket are: -16-

Summary of the content on the page No. 17

2.4 Panel Mounting The device is provided with an optional panel mounting bracket. The bracket support mounting the device on a plane surface securely. The mounting steps are: 1. Install the mounting bracket on the device unit. 2. Screw the bracket on the device unit. 3. Screw the device unit on a panel. 4. Make sure that there are proper heat dissipation from and adequate ventilation around the device. Do not place heavy objects on the device. -17-

Summary of the content on the page No. 18

The screw locations and final dimension are shown below: -18-

Summary of the content on the page No. 19

2.5 Applying Power The power specifications of the device are: Operating V oltage +7 ~ +30VDC Power Consumption Max. 2.5W @30VDC The device provides two types of power interfaces, terminal block and DC power jack for receiving DC power input from external power supply. Using Terminal Blocks Either DC1 interface or DC2 interface can be used to receive DC power from an external power system. Or, DC2 also can be used to deliver the power received on DC1 to next device in cascading way. DC1 + Vdc P

Summary of the content on the page No. 20

2 Power wires: 24 ~ 12AW G (IEC 0.5~2.5mm ) Install the power source wires with the plug properly. Screw the wire with plug securely. Then, plug in DC1 contacts. If cascading the power to next device is needed, install the power wires and plug for another switch. Then, use DC2 contacts. Note: Only up to four device units can be cascaded to receive power from one main power input source. -20-


Alternative user manuals
# User manual Category Download
1 KTI Networks DH-8T User manual Network Card 0
2 KTI Networks KF 221TX/3 User manual Network Card 0
3 KTI Networks KF223TX User manual Network Card 0
4 KTI Networks Gigabit Ethernet PCI Adapter KG-502T User manual Network Card 0
5 KTI Networks KCD-302 Series User manual Network Card 0
6 KTI Networks KG-500F User manual Network Card 0
7 KTI Networks KF-310 User manual Network Card 1
8 KTI Networks Web Smart Managed 10/100 Fast Ethernet Switches with VLan Support KS-117FM-V User manual Network Card 0
9 KTI Networks KF230TX User manual Network Card 0
10 KTI Networks Web Smart Managed 10/100 Fast Ethernet Switches with VLan Support KS-115FM-V User manual Network Card 0
11 KTI Networks KF-310L User manual Network Card 0
12 KTI Networks 100Base-FX Fast Ethernet PCI Adapter KF-221FX Ver.C User manual Network Card 0
13 Sony BTA-NW1A User manual Network Card 2
14 Sony BKMW-E3000 User manual Network Card 2
15 Sony AC-SQ950D User manual Network Card 0
16 Sony BBV RX100 User manual Network Card 3
17 Sony CLIE A-AVZ-100-11 User manual Network Card 1