Summary of the content on the page No. 1
User’s Manual
IPL T CR48
®
IP Link Tools
68-738-05 Rev. B
11 08
Summary of the content on the page No. 2
Precautions Safety Instructions • English Warning Power sources • This equipment should be operated only from the power source This symbol is intended to alert the user of important indicated on the product. This equipment is intended to be used with a main power operating and maintenance (servicing) instructions in system with a grounded (neutral) conductor. The third (grounding) pin is a safety the literature provided with the equipment. feature, do not attempt to bypass or disable it.
Summary of the content on the page No. 3
警告 安全须知 • 中文 电源 • 该设备只能使用产品上标明的电源。 设备 这个符号提示用户该设备用户手册中 必须使用有地线的供电系统供电。 第三条线 有重要的操作和维护说明。 (地线)是安全设施,不能不用或跳过。 拔掉电源 • 为安全地从设备拔掉电源,请拔掉所有设备后 这个符号警告用户该设备机壳内有暴 或桌面电源的电源线,或任何接到市电系统的电源线。 电源线保护 • 妥善布线, 避免被踩踏,或重物挤压。 露的危险电压,有触电危险。 维护 • 所有维修必须由认证的维修人员进行。 设备内部 注意 没有用户可以更换的零件。为避免出现触电危险不要自 阅读说明书 • 用户使用该设备前必须阅读并理 己试图打开设备盖子维修该设备。 解所有安全和使用说明。 通风孔 • 有些设备机壳上有通风槽或孔,它们是用来防止 保存说明书 • 用户应保存安全说明书以备将来使 机内敏感元件过热。 不要用任何东西挡住通风孔。 用。 锂电池 • 不正确的更换电池会有爆炸的危险。 必须使用 遵守警告 • 用户应遵守产品和用户指南上的所有安 与厂家推荐的相同或相近型号的电池。 按照生产厂的 全和操作说明。 建议处理废弃电池。
Summary of the content on the page No. 4
This page has been intentionally left blank.
Summary of the content on the page No. 5
IPL T S2 COM 100 R 2 1 LINK 2 4 ACT IPL T S2 COM R 1 ALINK CT100 2 2 4 IPL T CR48 INPUT RELAY 1 3 1 3 5 7 100 R LINK ACT 2 4 2 4 6 8 IPL T CR48 IPL T CR48 INPUT RELAY INPUT RELAY 1 3 1 3 5 7 100 1 3 1 3 5 7 100 R LINK R LINK ACT ACT 2 4 2 4 6 8 2 4 2 4 6 8 IPL T CR48 INPUT RELAY 1 3 1 3 5 7 100 R LINK ACT 2 4 2 4 6 8 TX RXR TS CTS TX RX RTS CTS Quick Start Guide — IPL T CR48 To install and set up an IPL T CR48 interface, follow these steps: Step 1 Turn all of the equipment off and disconnect it
Summary of the content on the page No. 6
Quick Start Guide — IPL T CR48, cont’d Step 4 Attach the input and relay connections to the IPL T unit. Step 5 Connect power cords and turn on the equipment in the following order: output devices (projector lift, screen lift, lights, etc.), IPL T CR48 interface, serial controller or computer (PC), then input devices (motion detector, alarms, photo eyes, etc.). Step 6 Configure the IPL T interface using the ARP command. Refer to “IPL T CR48 interface configuration” in chapter
Summary of the content on the page No. 7
Table of Contents Chapter One • Introduction .................................................... 1-2 About this Manual .................................................................... 1-2 About the IPL T CR48 Interface ............................................. 1-2 Features ........................................................................................ 1-2 Chapter Two • Installation and Operation ................... 2-2 Installation Overview ....................................
Summary of the content on the page No. 8
Table of Contents, cont’d Sending an e-mail alert through Telnet ............................4-7 Upgrading the firmwar e ........................................................4-8 Managing files ........................................................................4-8 Programmer’s Guide for the Telnet and Web Brose w r 4-10 Using the command/response table ...................................4-10 Symbol definitions ...............................................................4-11 Copyright
Summary of the content on the page No. 9
IPL T CR48 Chapter One 1 Introduction About this Manual About the IPL T CR48 Interface Features
Summary of the content on the page No. 10
Introduction About this Manual This manual contains information about the Extron IPL T CR48 (Extron part #60-544-05) Ethernet-based relay control interface, including how to install, configure, and operate it. About the IPL T CR48 Interface The Extron IPL T CR48 is an Ethernet-based relay control interface designed to be used as one of many nodes in a distributed control system environment, or as a stand-alone control interface allowing legacy products to link to today’s IP-based netwo
Summary of the content on the page No. 11
protection provide appropriate security. Contact closure input ports — Can be used to sense when a switch or relay has been activated. Easily connected — Provides RJ-45 auto-sense 10/100 Mbs Ethernet LAN connection. Easily configured and controlled — ® • Using a standard Web browser (Microsoft Internet ® ® Explorer V5.5, Netscape Navigator V6.0 or higher) and Web-based interface. • Using a standard Telnet client application. • Requires no centralized processor to operate within a sy
Summary of the content on the page No. 12
Introduction, cont’d 1-4 IPL T CR48 • Introduction
Summary of the content on the page No. 13
IPL T CR48 Chapter Two 2 Installation and Operation Installation Overview Mounting the IPL T CR48 Rear Panel Features and Cabling Operation
Summary of the content on the page No. 14
Installation and Operation Installation Overview To install and set up an IPL T CR48 relay control interface, follow these steps: 1. Turn all of the equipment off. Make sure that the input devices (motion detectors, alarms, photo eyes, etc.), the IPL unit, the output devices (projector or screen lifts, etc.) and the serial controller are all turned off and disconnected from the power source. 2. Mount the IPL T CR48 unit. See “Mounting the IPL T CR48” below. 3. Attach the cables. See “Co
Summary of the content on the page No. 15
IPL T CR48 IPL T CR48 INPUT RELAY INPUT RELAY 100 1 3 1 3 5 7 100 1 3 1 3 5 7 R LINK R LINK ACT ACT 2 4 2 4 6 8 2 4 2 4 6 8 IPL T CR48 IPL T CR48 INPUT RELAY INPUT RELAY 100 100 R 1 3 1 3 5 7 R 1 3 1 3 5 7 LINK LINK ACT ACT 2 4 2 4 6 8 2 4 2 4 6 8 IPL T CR48 INPUT RELAY 1 3 1 3 5 7 100 R LINK ACT 2 4 2 4 6 8 MDA SERIES DISTRIBUTION AMPLIFIER 1U Rack Shelf 1/4 Rack Width False Front Face Plate Use 2 mounting holes on opposite corners. (2) 4-40 x 3/16" Screws Figure 2-1 — Mounting the interface
Summary of the content on the page No. 16
IPL T S2 COM 100 R 2 1 LINK 2 4 ACT IPL T S2 COM R 2 1 2 4 ALINK CT100 IPL T CR48 INPUT RELAY 100 1 3 1 3 5 7 R LINK ACT 2 4 2 4 6 8 TX RXRTS CTS TX RX RTS CTS Installation and Operation, cont’d Furniture or projector mounting In addition to using the IPL T CR48 unit on a rack, it can also be furniture or projector mounted. Furniture mount or projector mount the interface using the optional mounting kit (Extron part #70-212-01, furniture, or Extron part #70-217-01, projector) as follows: 1.
Summary of the content on the page No. 17
Rear Panel Features and Cabling All connections, including power, input and output, and control, are on the back panel of the IPL T CR48 interface. 7 00-05-A6-00-00-01 1 2 3 4 INPUT POWER LAN RELAY 12V 0.5A 1 2 3 4 5 6 7 8 2 3 4 5 6 1 Figure 2-4 — IPL T CR48 interface back panel Power a Power connection — Plug the external 12 V power supply into this connector. The power supply is included with the unit. C When connecting the power supply, voltage polarity is extremely importa
Summary of the content on the page No. 18
Installation and Operation, cont’d W The two power cord wires must be kept separate while the power supply is plugged in. Remove power before continuing. To verify the polarity before connection, plug in the power supply with no load and check the output with a voltmeter. Ethernet/LAN LAN Activity LED — Yellow LED blinks to indicate LAN b activity. LAN connector — Plug an RJ-45 jack into this socket to c connect the unit to a computer network. Use a straight- through cable to connect
Summary of the content on the page No. 19
Screen Control Projector Lift Control Projector Extron IPL T CR48 Ethernet Control Interface Lighting System Figure 2-7— Example application using input and relay ports Operation Connect power cords and turn on the relay controlled output devices (projector lifts, screen lifts, lights, etc.), input (trigger) devices (motion detectors, alarms, photo eyes, etc.), relay interface, and network devices (PC, laptop, network equipment). Check indicator LEDs on the PC/laptop, on the interface, and
Summary of the content on the page No. 20
Installation and Operation, cont’d Front panel indicators The front panel of the IPL T CR48 has several indicator LEDs which show the current status of communications to and from the unit. A reset button is also available from the front panel, in a a small recess next to the Power LED ( ). IPL T CR48 INPUT RELAY 5 100 1 3 1 3 5 7 R LINK 6 ACT 7 2 4 2 4 6 8 3 4 1 2 Figure 2-8— IPL T CR48 front panel Power LED — A green LED lights to indicate that the a interface is receiving power. Reset b