Extron electronic Cable Cubby 600 user manual

User manual for the device Extron electronic Cable Cubby 600

Device: Extron electronic Cable Cubby 600
Category: Network Card
Manufacturer: Extron electronic
Size: 1.53 MB
Added : 5/3/2013
Number of pages: 33
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Extron electronic Cable Cubby 600. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Extron electronic Cable Cubby 600.

For your convenience

If looking through the Extron electronic Cable Cubby 600 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Extron electronic Cable Cubby 600 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Extron electronic Cable Cubby 600 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Extron electronic Cable Cubby 600 User manual - Online PDF
Advertisement
« Page 1 of 33 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Extron electronic Cable Cubby 600 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Extron electronic Cable Cubby 600. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

User’s Manual
®
Cable Cubby 200
®
Cable Cubby 300C
®
Cable Cubby 300S
®
Cable Cubby 600
®
Cable Cubby 800
Surface Access Products for Cables, AAPs, and Power Outlets
Extron Electronics, USA Extron Electronics, Europe Extron Electronics, Asia Extron Electronics, Japan
1230 South Lewis Street Beeldschermweg 6C 135 Joo Seng Road, #04-01 Kyodo Building
68-701-01 Rev. F
Anaheim, CA 92805 3821 AH Amersfoort PM Industrial Building 16 Ichibancho
06 06
USA The Netherlands Singapore 368363 Chiyoda-ku, To

Summary of the content on the page No. 2

Summary of the content on the page No. 3

Table of Contents Chapter One � Introduction .................................................... 1-1 ® About the Cable Cubby Products ....................................... 1-2 Features ........................................................................................ 1-5 Chapter Two � Installation ...................................................... 2-1 Installation Overview ............................................................... 2-2 Preparing the Routing Template ...

Summary of the content on the page No. 4

Table of Contents, cont’d ® Cable Cubby Products Chapter One 1 Introduction ® About the Cable Cubby Products Features 68-701-01 Rev. F 06 06 All trademarks mentioned in this manual are the properties of their respective owners. ® ii Cable Cubby Products � Table of Contents

Summary of the content on the page No. 5

Introduction ® About the Cable Cubby Products The Extron Cable Cubbies are furniture-mounted, architectural solutions for inconspicuous cable access and connection points. When cables are not in use, they can be stored out of the way while remaining connected to the presentation system. Most US/domestic Cable Cubby models provide two unswitched USA AC power outlets. The US/domestic Cable Cubby 200 provides one outlet. Each of the international versions provides a single unswitched

Summary of the content on the page No. 6

Introduction, cont’d The installed Cable Cubbies fi t nearly fl ush within a table or Features podium top, storing the AAPs and cables out of the way and � Easy access to cables and AAPs out of sight. To access the AAPs and connectors, lift the lid � Durable mechanical movement (fi gure 1-2). Half-moon cutouts in the lid allow you to run cables in or out and then close the lid. For Cable Cubby 300s, � Cable Cubby 300, 600, and 800 available in a variety of 600s, and 800s, you can lower

Summary of the content on the page No. 7

Introduction, cont’d ® Cable Cubby Products Chapter Two 2 Installation Installation Overview Preparing the Routing Template Preparing the Table Installing the Cables and AAPs Mounting the Cable Cubby ® 1-6 Cable Cubby Products � Introduction

Summary of the content on the page No. 8

Width of Mounting Surface Installation Installation Overview Preparing the Routing Template Install and set up the Cable Cubby enclosures as follows: Extron provides metal templates for the Cable Cubbies at no charge. See Routing Template Part Numbers, in appendix A, 1 If you plan to use a mounting template that has not been Reference Information, for part numbers. Extron recommends prepared, prepare the template. See Preparing the Routing using this template as a guide to cut the hole

Summary of the content on the page No. 9

Installation, cont’d Wear safety glasses when operating the router. W Preparing the Table Failure to comply can result in eye injury. The preferred and recommended method for preparing the table for square Cable Cubbies and one of two preferred methods for 4. Using a router with a 5/8" (or 16 mm) outside diameter the Cable Cubby 300C is to use the appropriate Extron routing guide bushing and a 1/2" (or 12 mm or 12.7 mm) diameter template and a router. straight router bit, carefully cut th

Summary of the content on the page No. 10

Installation, cont’d Preparing the table with a hole saw Installing the Cables and AAPs (Cable Cubby 300C only) Each Cable Cubby 300, 600, and 800 model ships with one or two moveable AAP shelf assemblies. The Cable Cubby 200’s Prepare the table with a hole saw as follows: AAP shelf is fi xed in place. 1. On the tabletop or other installation surface, mark the 6" circle, then fi nd and mark the center of the circle. AAP shelf brackets (CC 300, 600, 800) Wear safety glasses when operating th

Summary of the content on the page No. 11

Installation, cont’d Install cables in the channels as follows: Installing the power module (CC 300, 600, 800) 1. Remove a segment of a set of split AAPs by unscrewing From the underside of the Cable Cubby, gently push the power the nuts on the underside of the bracket that fastens the module into the desired position at the desired elevation. Secure the power module into position with four Phillips head screws. plate to the shelf (CC 200) or shelf bracket (CC300, 600, or 800) (fi gure 2-4

Summary of the content on the page No. 12

Installation, cont’d 3. Install a second stand-off, in accordance with steps 1 and 2. Installing the shelf assembly (CC 300, 600, 800) 4. Slide the stand-offs back and forth in the horizontal slots to From the underside of the Cable Cubby, gently push the AAP position them so that the cables easily rise and lower but shelf assembly into the desired position at the desired elevation. Ensure there is enough space above the AAP assembly for the do not fall below the stand-offs. Cable Cubby li

Summary of the content on the page No. 13

Installation, cont’d 3. Carefully lower the Cable Cubby into the hole to test the 8. Cable Cubby 200 — Use the four included 6-32 x 1/2" fi t. If necessary, remove the enclosure and use a fi le or rasp screws to fasten the Cable Cubby 200 to the table to enlarge or smooth the edges of the opening (fi gure 2-7). (fi gure 2-8). 15-pin HD Cable Audio Cable Cable Cubby 300C Surface-Mountable RJ-45 Cable Enclosure for Cables, AAPs & AC Power Outlet Figure 2-8 — Cable Cubby, installation view Mounting

Summary of the content on the page No. 14

Installation, cont’d ® Cable Cubby Products Chapter 3 3 Maintenance and Modifi cations Removing and Replacing the Cable Cubby Replacing Cables or an AAP Adding an Additional Power Module (CC 600, CC 800) ® 2-14 Cable Cubby Products � Installation

Summary of the content on the page No. 15

Maintenance and Modifi cations The Cable Cubby can be modifi ed in the future to change cables, to replace an AAP, or to add a second power module. These modifi cation may require removing the cubby from the table. Removing and Replacing the Cable Cubby You may need to remove the cubby from the table in which it is mounted to replace cables or AAPs, to adjust the height of the AAP assemblies, or to install a second power module. Figure 3-1 shows removal of the Cable Cubby 300, 600, or 800

Summary of the content on the page No. 16

Maintenance and Modifi cations, cont’d 4. Cable Cubby 200 — Remove the screws at the four corners 10. Cable Cubby 300, 600, and 800 — Snugly tighten the that secure the cubby to the table (fi gure 3-2). Phillips head screws on the screw clamps to secure the enclosure to the surface. 11. Cable Cubby 300, 600, and 800 — Tighten the locking thumbscrews on the screw clamps to lock the clamp in position. 12. Cable Cubby 200 — Fasten the Cable Cubby 200 to the table with the four 6-32 x 1/2" screw

Summary of the content on the page No. 17

Maintenance and Modifi cations, cont’d Figure 3-4 shows typical confi gurations before and after Adding an Additional Power Module you add a second power module to an international (CC 600 and CC 800) Cable Cubby 800. Each additional power module occupies two (USA/domestic Before After models) or three (international models) of the cubby’s AAP spaces, reducing the amount of AAP space available in the cubby for cable pass through (split) or passive AAPs. Use the following guidelines as ap

Summary of the content on the page No. 18

Maintenance and Modifi cations, cont’d � Cable Cubby 600 and 800 US/Domestic models — Figure 3-6 shows typical confi gurations before and after You probably do need replacement shelf brackets you add a second US/Domestic power module to a when you add a US/Domestic power module to US/domestic Cable Cubby 800 and suggests rack shelf a US/Domestic Cable Cubby, because the power confi gurations to replace the lost shelf space. module takes up two spaces in a cubby that, in its Before After sta

Summary of the content on the page No. 19

Maintenance and Modifi cations, cont’d ® 4 Cable Cubby Products From the underside of the Cable Cubby, gently push the additional power module into the desired position at the desired elevation. Secure the power module into position with the included four Phillips head screws (fi gure 3-7). Extron Cable Cubby 600 2 Screws ea. side Appendix A A Figure 3-7 — Installing the power module 5 If desired, assemble and install replacement AAP shelf assemblies. Remember that the cable pull functio

Summary of the content on the page No. 20

Reference Information Specifi cations General d Rack mount .................................... No, but furniture mountable Enclosure type .............................. Metal H H Enclosure dimensions C Use the appropriate metal Extron routing template or refer to D D W W the surface cutout dimensions here before cutting a hole in the furniture or other surface. Pay special attention to the direction the unit will face; the unit’s AAP and connector access side Cable Cubby 300C Cable Cubby


Alternative user manuals
# User manual Category Download
1 Extron electronic 604-02 User manual Network Card 0
2 Extron electronic 488-01 User manual Network Card 2
3 Extron electronic AC AAP User manual Network Card 2
4 Extron electronic AAP 102 FSR Series User manual Network Card 1
5 Extron electronic 70-110-04 User manual Network Card 1
6 Extron electronic AAP 102 FSR User manual Network Card 4
7 Extron electronic Active Audio AAP User manual Network Card 1
8 Extron electronic 604-01 User manual Network Card 0
9 Extron electronic 397-01 User manual Network Card 1
10 Extron electronic Architectural Interface CIA114F5 User manual Network Card 0
11 Extron electronic Architectural Interface RGB 440 User manual Network Card 1
12 Extron electronic Architectural Series Universal Interfaces with Audio and ADSP RGB 508 User manual Network Card 1
13 Extron electronic Architectural Series Universal Interfaces with Audio and ADSP RGB 500/Dual User manual Network Card 1
14 Extron electronic Architectural Interface CIA114 User manual Network Card 1
15 Extron electronic Architectural Series Universal Interfaces with Audio and ADSP RGB 568 User manual Network Card 1
16 Sony BTA-NW1A User manual Network Card 2
17 Sony BKMW-E3000 User manual Network Card 2
18 Sony AC-SQ950D User manual Network Card 0
19 Sony BBV RX100 User manual Network Card 3
20 Sony CLIE A-AVZ-100-11 User manual Network Card 1