AMX AXlink Bus Controllers AXB-232++ user manual

User manual for the device AMX AXlink Bus Controllers AXB-232++

Device: AMX AXlink Bus Controllers AXB-232++
Category: Network Card
Manufacturer: AMX
Size: 0.31 MB
Added : 10/27/2013
Number of pages: 20
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for AMX AXlink Bus Controllers AXB-232++. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with AMX AXlink Bus Controllers AXB-232++.

For your convenience

If looking through the AMX AXlink Bus Controllers AXB-232++ user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual AMX AXlink Bus Controllers AXB-232++ on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual AMX AXlink Bus Controllers AXB-232++ to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
AMX AXlink Bus Controllers AXB-232++ User manual - Online PDF
Advertisement
« Page 1 of 20 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual AMX AXlink Bus Controllers AXB-232++ but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to AMX AXlink Bus Controllers AXB-232++. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

instruction manual
AXB-232++
RS-232/422/485 Interface
AXlink Bus Controllers

Summary of the content on the page No. 2

Summary of the content on the page No. 3

Table of Contents Table of Contents Product Information .................................................................................................1 Front Panel........................................................................................................................ 1 Rear Panel ........................................................................................................................ 1 Specifications ..............................................................

Summary of the content on the page No. 4

Table of Contents ii AXB-232++ RS-232/422/485 Interface

Summary of the content on the page No. 5

Product Information Product Information The AXB-232++ RS-232/422/485 Interface is an AXlink bus controller that provides remote control for devices that require a variety of control protocols. The AXB-232++ extends RS-232, RS-422, or RS-485 control to remote sources over the 4-wire AXlink data/power bus. Onboard processing and memory allows the controller to take on complex tasks by itself, reducing the processing burden for the Axcess control system. For example, the control system can use

Summary of the content on the page No. 6

Product Information Specifications The following table lists the specifications for the AXB-232++. Specifications Power 12 VDC @ 160 mA Processor On board 32-bit processor and 384K (of non-volatile memory) run Axcess programs independent of the control system. This relieves the AXlink bus and controller for the processing time for controlling those devices. (Requires Axcess Version 3.0 or higher.) Asynchronous data • Baud rates - 300, 600, 1200. 2400, 4800, 9600, 19200 and 38400. standards 5

Summary of the content on the page No. 7

Installation and Wiring Installation and Wiring The AXB-232++ can be used as an independent RS-232/422/485-controlled interface by setting the internal jumpers. Configure the communication parameters using the DIP switches on the front panel. Setting the Internal Jumpers JP4 Internal jumper JP4 Internal jumper JP5 JP5 front 1998 CORP. AXB-232++ FIG. 3 Location of internal jumpers Setting jumper JP4 to terminate RS-422 input with 100 ohms Terminating a device involves installing a 100 ohm

Summary of the content on the page No. 8

Installation and Wiring Setting jumper JP5 to set the RS-422 port for RS-485 use 1. Disconnect the RS-232/422/485 connectors. 2. Unscrew the two screws on the rear panel, and remove the panel. 3. Slide the circuit board out of the enclosure. 4. Locate the JP5 jumper (see FIG. 3 on page 3). 5. Set jumper JP5 to the ON position (the default setting is OFF). 6. Slide the circuit board back into the enclosure. 7. Replace the panel, and refasten the screws. 8. Reconnect the RS-232/422/485 connectors.

Summary of the content on the page No. 9

Installation and Wiring Setting the RS-232/422 DIP switch Set the stop bits, data bits, parity, and baud rate on the RS-232/422 DIP switch, located on the front panel (see FIG. 1 on page 1). The AXB-232++ supports the following asynchronous data standards: Stop bits 1 and 2 Data bits 7, 8, and 9 Parity None, Odd, Even, Mark, and Space Baud rates 300, 600, 1,200, 2,400, 4,800, 9,600, 19,200 and 38,400. 57,600 is achieved by setting the DIP switch to 300 baud, and using the ’BAUD

Summary of the content on the page No. 10

Installation and Wiring Wiring Devices to the AXB-232++ Preparing captive wires To connect the wiring into a captive-wire connector: 1. Strip 1/4 inch off the wire insulation for all four wires. 2. Tin 2/3 of the exposed wire. 3. Insert each wire into the appropriate captive-wire connector up to the insulation. 4. Tighten the captive screws to secure the fit in the connector. If the device is using a separate power supply, do not connect the power wiring from the AXB-232++ to that device. Wirin

Summary of the content on the page No. 11

Installation and Wiring Using RS-232 When communicating via RS-232, connect the wiring as shown in FIG. 6. GND GND AXB- Device RX RX 232++ TX TX +12V RX - RX + TX - TX + FIG. 6 RS-232 wiring Using Hardware Handshaking When the controlled device requires hardware handshaking, connect the wiring as shown in FIG. 7. 1 AXB-232++ 2 CTS RTS Device CTS 3 RTS 4 FIG. 7 Hardware handshaking wiring Using RS-422 When communicating via RS-422, connect the wiring as shown in FIG. 8. GND R

Summary of the content on the page No. 12

Installation and Wiring Rack-mounting the AXB-232++ (optional) To rack-mount the AXB-232++ into the optional AC-RK Accessory Rack Kit: 1. Remove any connected power, and AXlink and RS-232 connectors from the rear panel. 2. Remove the two screws on the front panel of the AXB-232++. 3. Remove the front panel and space bracket behind the panel. 4. Place the unit in the appropriate opening in the AC-RK. 5. Place the front panel of the AXB-232++ on the front of the rack, over the unit. 6. Fasten the

Summary of the content on the page No. 13

Programming Programming Send_Commands The AXB-232++ supports the same command set as the AXC-232. The following table lists the AXB-232++ Send_Commands. AXB-232++ Send_Commands B9MOFF Syntax: Sets data bit mode to normal 'B9MOFF' with DIP switch settings Example: (default). SEND_COMMAND AXB232,'B9MOFF' Sets the data bit mode to normal. B9MON Syntax: Enables a special mode to 'B9MON' override DIP switch settings. The mode, nine data bits with one stop bit, overrides the data, stop, and pari

Summary of the content on the page No. 14

Programming AXB-232++ Send_Commands (Cont.) CHARD Syntax: Sets delay between all 'CHARD-

Summary of the content on the page No. 15

Programming AXB-232++ Send_Commands (Cont.) RXOFF Syntax: AXB-232++ does not pass on 'RXOFF' received characters to the Example: Master (default). SEND_COMMAND AXB232,'RXOFF' AXB-232++ does not pass on received characters to the master. RXON Syntax: Enables AXB-232++ to send 'RXON' incoming characters received Example: to the Master. SEND_COMMAND AXB232,'RXON' Enables AXB-232++ to send incoming characters received to the master. The AXB-EM automatically sends this command to the AXB-232++ whe

Summary of the content on the page No. 16

Programming Send_String Escape Sequences The AXB-232++ does not regard certain three-character combinations within a Send_String program as literal characters, but as commands. The following table lists those combinations. Send_String Escape Sequences 27,17,

Summary of the content on the page No. 17

Programming AXB-232++ Program Statements The Axcess program of the AXB-232++ communicates with the master as Device 0. Its device communicates with the RS232/422 Input/Output (I/O) of the AXB-232++ as Device 1. The following table lists AXB-232++ statements. AXB-232++ Program Statements Statement Function Places strings that come from the Master into buffer. If no CREATE_BUFFER CREATE_BUFFER 0 exists, the incoming strings from the Master are sent out the RS232 port. 0,buffer CREATE_BUFFER

Summary of the content on the page No. 18

Programming Xmodem Timing Commands The following table lists the AXB-232++ Xmodem timing commands. Xmodem timeouts exist to accommodate potential Ethernet delays and for consistency among and within products. Any Xmodem timing command will change timing and retries for Axcess code download as well as Softrom transfer. Xmodem Timing Commands Command Description 'TIMEOUT XX' Xmodem timeouts via the Program Port. (Default is 10 sec.) SEND_COMMAND Over AXlink, where XX is from one to 50 seconds i

Summary of the content on the page No. 19

Programming Reserved Channels The following table lists the channels reserved on Device 0. Reserved Channels Channel Function Channel 254 This is only valid within the device and is not sent to the AXlink Master. Reflects AXlink status: � When AXlink is active, this channel is on. � When AXlink is inactive, this channel is off. � When this channel changes state, the AXB-232++ generates a PUSH or RELEASE. Channel 255 Reflects the state of the CTS input. If the AXB-232++ receives a 'CTSPSH' comma

Summary of the content on the page No. 20

AMX reserves the right to alter specifications without notice at any time. ARGENTINA • AUSTRALIA • BELGIUM • BRAZIL • CANADA • CHINA • ENGLAND • FRANCE • GERMANY • GREECE • HONG KONG • INDIA • INDONESIA • ITALY • JAPAN LEBANON • MALAYSIA • MEXICO • NETHERLANDS • NEW ZEALAND • PHILIPPINES • PORTUGAL • RUSSIA • SINGAPORE • SPAIN • SWITZERLAND • THAILAND • TURKEY • USA ATLANTA • BOSTON • CHICAGO • CLEVELAND • DALLAS • DENVE


Alternative user manuals
# User manual Category Download
1 AMX Control Card RDC-DC User manual Network Card 2
2 AMX CSG SIP Communications Gateway 544/580 User manual Network Card 1
3 AMX Audio-Only Module MAX-AOM User manual Network Card 0
4 AMX Control System Accessories Anterus User manual Network Card 0
5 AMX AXC-INP8 User manual Network Card 0
6 AMX NetLinx Integrated Controller NXI User manual Network Card 4
7 AMX DTMF+ Interface AXB-DTMF+ User manual Network Card 0
8 AMX AXR-IRSM+ User manual Network Card 1
9 AMX Enhanced Master RS-232 Controller AXB-EM232 User manual Network Card 8
10 AMX IP Link Interface RMS User manual Network Card 0
11 AMX Metreau 7-Button Keypad MET-7 User manual Network Card 2
12 AMX Incandescent Dimmer Module RDM-INC User manual Network Card 0
13 AMX Dual Zero Cross Module RDM-2ZC User manual Network Card 0
14 AMX MetreauTM 13-Button Keypad MET-13 User manual Network Card 1
15 AMX ICSNet Daughter Card NXA-ICSNET User manual Network Card 0
16 Sony BTA-NW1A User manual Network Card 2
17 Sony BKMW-E3000 User manual Network Card 2
18 Sony AC-SQ950D User manual Network Card 0
19 Sony BBV RX100 User manual Network Card 3
20 Sony CLIE A-AVZ-100-11 User manual Network Card 1