Alesis EC-1 A ES/EBU user manual

User manual for the device Alesis EC-1 A ES/EBU

Device: Alesis EC-1 A ES/EBU
Category: Network Card
Manufacturer: Alesis
Size: 0.11 MB
Added : 6/28/2013
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Alesis EC-1 A ES/EBU. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Alesis EC-1 A ES/EBU.

For your convenience

If looking through the Alesis EC-1 A ES/EBU user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Alesis EC-1 A ES/EBU on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Alesis EC-1 A ES/EBU to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Alesis EC-1 A ES/EBU User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Alesis EC-1 A ES/EBU but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Alesis EC-1 A ES/EBU. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

ALESIS
EC-1 AES/EBU
INTERFACE CARD
FOR THE M20 PROFESSIONAL 20-BIT DIGITAL
RECORDER
OWNER’S MANUAL
FIRST EDITION VERSION 1.00
APPLIES TO M20 OPERATING SOFTWARE VERSION 1.11
©1998 ALESIS CORPORATION

Summary of the content on the page No. 2

EC-1 AES/EBU Interface, Appendix E EC-1 MANUAL 1.00

Summary of the content on the page No. 3

APPENDIX E EC-1 AES/EBU INTERFACE This document covers only those aspects unique to the EC-1 card and should be inserted into the binder with the M20 manual. TABLE OF CONTENTS Important Safety Instructions..............................................................................................................2 Safety symbols used in this product ...................................................................................................2 CE Declaration of Conformity..................

Summary of the content on the page No. 4

EC-1 AES/EBU Interface, Appendix E IMPORTANT SAFETY INSTRUCTIONS SAFETY SYMBOLS USED IN THIS PRODUCT This symbol alerts the user that there are important operating and maintenance instructions in the literature accompanying this unit. This symbol warns the user of uninsulated voltage within the unit that can cause dangerous electric shocks. All safety warnings in the M20 manual (pages v and vi) apply to the EC-1 as well. CE DECLARATION OF CONFORMITY Manufacturer’s Name: Alesis Corporatio

Summary of the content on the page No. 5

Appendix E, EC-1 AES/EBU Interface October, 1998 EC-1 MANUAL 1.00 E-3

Summary of the content on the page No. 6

EC-1 AES/EBU Interface, Appendix E ABOUT THE EC-1 The EC-1 is an optional AES/EBU protocol expansion card designed exclusively for the M20. It provides 8 simultaneous channels of AES/EBU digital audio inputs and outputs via eight XLR type jacks (four input channel pairs and four output channel pairs). The EC-1 may be installed directly into the M20’s rear panel for simple system integration and flexibility. With the EC-1 installed, the M20 can receive and transmit AES/EBU digital audio and di

Summary of the content on the page No. 7

Appendix E, EC-1 AES/EBU Interface OVERVIEW OF MAIN FUNCTIONS ABOUT AES/EBU DIGITAL AUDIO The AES/EBU protocol is the most common professional standard for transmitting digital audio. It is a two-channel protocol designed for stereo pairs, so transmitting from the eight-channel ADAT M20 requires the use of four sets of AES/EBU jacks: four XLR male jacks for output, and four XLR female jacks for input. The AES/EBU input jacks may be routed (or “normalled”) to multiple ADAT tracks using the M20

Summary of the content on the page No. 8

EC-1 AES/EBU Interface, Appendix E INSTALLATION PRECAUTIONS Install the EC-1 only if you have had some experience with similar devices and feel competent to do so. If the following instructions are not clear to you, have your dealer or a trained technician install it for you. Hazardous voltages are present within the chassis. Do not remove the top panel without first unplugging the unit from AC power! EC-1 CONNECTION TO M20 MAIN CIRCUIT BOARD The EC-1 comes with a 40-pin flexible cable. T

Summary of the content on the page No. 9

Appendix E, EC-1 AES/EBU Interface BASIC OPERATION SELECTING AES/EBU (I/O CARD) AS THE DIGITAL SOURCE When using digital inputs, the Digital Source function selects one of three digital input options. The I/O CARD option will appear in the display only if an I/O card (such as the Alesis EC-1 card) is installed in the M20. With the EC-1 card installed, pressing the Digital Source button (next to the meter display) toggles through the available sources, such as ADAT OPTICAL, TRACK COPY, and I/O C

Summary of the content on the page No. 10

EC-1 AES/EBU Interface, Appendix E Once again, we must remind you: if independent (non-synchronous) AES/EBU sources are connected to the EC-1 card, audio cannot be monitored (or recorded) simultaneously since the clock for each input channel pair is independent. When monitoring AES/EBU digital audio from more than one channel pair, all of the AES/EBU sources must be synchronous, i.e., controlled by the same sample clock. IF THE EC-1 IS NOT INSTALLED IN THE MASTER M20: If the EC-1 card is insta

Summary of the content on the page No. 11

Appendix E, EC-1 AES/EBU Interface Note: The above illustrations assume that the source tracks of the M20 are set to receive digital input (as shown by a “D” under the meter for each track). IF THE INPUT SELECTION IS ANALOG AND AES/EBU SIMULTANEOUSLY: If you have INPUT SELECT configured for analog and AES/EBU input, input routing must use the one-to-one configuration. This is the case because using any other bus configuration will route the selected I/O card digital source tracks (e.g. tracks 1

Summary of the content on the page No. 12

EC-1 AES/EBU Interface, Appendix E E-10 EC-1 MANUAL 1.00


Alternative user manuals
# User manual Category Download
1 Sony BTA-NW1A User manual Network Card 2
2 Sony BKMW-E3000 User manual Network Card 2
3 Sony AC-SQ950D User manual Network Card 0
4 Sony BBV RX100 User manual Network Card 3
5 Sony CLIE A-AVZ-100-11 User manual Network Card 1
6 Sony BTA-NW1 User manual Network Card 11
7 Sony AC-NWUM50 User manual Network Card 1
8 Sony AR-B1474 User manual Network Card 2
9 Sony BKM-FW32 User manual Network Card 1
10 Sony 4000CL-MAV-PBIO User manual Network Card 1
11 Sony FA-ST1AM User manual Network Card 0
12 Sony MVC-FDR3/FDR3E User manual Network Card 1
13 2Wire third-party wireless Ethernet adapters User manual Network Card 1
14 3Com 10/100BASE-T4 PCI User manual Network Card 1
15 3Com 3C389 User manual Network Card 0