Agilent Technologies E3632A user manual

User manual for the device Agilent Technologies E3632A

Device: Agilent Technologies E3632A
Category: Network Card
Manufacturer: Agilent Technologies
Size: 3.72 MB
Added : 4/5/2014
Number of pages: 169
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Agilent Technologies E3632A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Agilent Technologies E3632A.

For your convenience

If looking through the Agilent Technologies E3632A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Agilent Technologies E3632A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Agilent Technologies E3632A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Agilent Technologies E3632A User manual - Online PDF
Advertisement
« Page 1 of 169 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Agilent Technologies E3632A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Agilent Technologies E3632A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

User’s Guide
3DUW1XPEHU(
$SULO
)RU6DIHW\LQIRUPDWLRQ:DUUDQWLHVDQG5HJXODWRU\LQIRUPDWLRQ
VHHWKHSDJHVEHKLQGWKH,QGH[
‹&RS\ULJKW$JLOHQW7HFKQRORJLHV,QF
$OO5LJKWV5HVHUYHG
$JLOHQW($
'&3RZHU6XSSO\

Summary of the content on the page No. 2

The Agilent E3632A is a high performance 120 watt-dual range DC power supply with GPIB and RS-232 interfaces. The combination of bench-top and system features in this power supply provides versatile solutions for your design and test requirements. Convenient bench-top features • Dual range • Easy-to-use knob control settings • Highly visible vacuum-fluorescent display meters • High accuracy and high resolution • Remote voltage sensing • Overvoltage and overcurrent protection • Output on/off •

Summary of the content on the page No. 3

The Front Panel at a Glance 1 15V/7A range selection key 8 Error/Calibrate key 2 30V/4A range selection key 9 I/O Configuration/Secure key 3 Overvoltage protection key 10 Output On/Off key 4 Overcurrent protection key 11 Control knob 5 Display limit key 12 Resolution selection keys 6 Recall operating state key 13 Voltage/current adjust selection key 7 Store operating state/Local key 2

Summary of the content on the page No. 4

1 15V/7A range selection key Selects the 15V/7A range and allows the full rated output to 15V/7A. 2 30V/4A range selection key Selects the 30V/4A range and allows the full rated output to 30V/4A. 3 Overvoltage protection key Enables or disables the overvoltage protection function, sets trip voltage level, and clears the overvoltage condition. 4 Overcurrent protection key Enables or disables the overcurrent protection function, sets trip current level, and clears the overcurrent conditio

Summary of the content on the page No. 5

Front-Panel Voltage and Current Limit Settings You can set the voltage and current limit values from the front panel using the following method. Use the voltage/current adjust selection key, the resolution selection keys, and the control knob to change the voltage and current limit values. 1 Select the desired range using the range selection keys after turning on the power supply. 2 Press the Display Limit key to show the limit values on the display. 3 Move the blinking digit to the appropria

Summary of the content on the page No. 6

Display Annunciators Adrs Power supply is addressed to listen or talk over a remote interface. Rmt Power supply is in remote interface mode. 15V Shows the 15V/7A range is selected. 30V Shows the 30V/4A range is selected. OVP The overvoltage protection function is enabled when the annunciator turns on or the overvoltage protection circuit has caused the power supply to shutdown when the annunciator blinks. OCP The overcurrent protection function is enabled when the annunciator turns on or th

Summary of the content on the page No. 7

The Rear Panel at a Glance 1 Power-line voltage setting 4 Power-line module 2 Power-line fuse-holder assembly 5 GPIB (IEEE-488) interface connector 3 AC inlet 6 RS-232 interface connector I/O Config Use the front-panel key to: • Select the GPIB or RS-232 interface (see chapter 3). • Set the GPIB bus address (see chapter 3). • Set the RS-232 baud rate and parity (see chapter 3). 6

Summary of the content on the page No. 8

In This Book General Information Chapter 1 contains a general description of your power supply. This chapter also provides instructions for checking your power supply, connecting to ac power, and selecting power-line voltage. Initial Operation Chapter 2 ensures that the power supply develops its rated outputs and properly responds to operation from the front panel. Front-Panel Operation Chapter 3 describes in detail the use of front-panel keys and how they are used to operate the p

Summary of the content on the page No. 9

8

Summary of the content on the page No. 10

Contents Contents Chapter 1 General Information Safety Considerations 14 Safety and EMC Requirements 14 Options and Accessories 15 Options 15 Accessories 15 Description 16 Installation 19 Initial Inspection 19 Cooling and Location 19 Input Power Requirements 22 Power-Line Cord 22 Power-Line Voltage Selection 22 Chapter 2 Initial Operation Preliminary Checkout 27 Power-On Checkout 28 Output Checkout 29 Voltage Output Checkout 29 Curr

Summary of the content on the page No. 11

Contents Chapter 3 Front-Panel Operation (continued) Disabling the Output 50 Disabling the Output Using an External Relay 51 Knob Locking 51 System-Related Operations 52 Self-Test 52 Error Conditions 53 Display Control 54 Firmware Revision Query 55 SCPI Language Version 55 Remote Interface Configuration 56 Remote Interface Selection 56 GPIB Address 57 Baud Rate Selection (RS-232) 57 Parity Selection (RS-232) 57 To Set the GPIB Address 5

Summary of the content on the page No. 12

Contents Contents Chapter 4 Remote Interface Reference SCPI Command Summary 73 Simplified Programming Overview 78 Using the APPLy Command 78 Using the Low-Level Commands 78 Reading a Query Response 79 Selecting a Trigger Source 79 Power Supply Programming Ranges 80 Using the APPLy Command 81 Output Setting and Operation Commands 82 Triggering Commands 89 Trigger Source Choices 89 Triggering Commands 91 System-Related Commands 92 Calibration Com

Summary of the content on the page No. 13

Contents Chapter 5 Error Messages Execution Errors 123 Self-Test Errors 128 Calibration Errors 129 Chapter 6 Application Programs C++ Example for GPIB(IEEE 488) 133 Excel 5.0 Example for Windows 3.1 and GPIB 135 Chapter 7 Tutorial Overview of Agilent E3632A Operation 141 Output Characteristics 143 Unregulated State 145 Unwanted Signals 145 Connecting the Load 147 Output Isolation 147 Multiple Loads 147 Remote Voltage Sensing 148 Load Considerat

Summary of the content on the page No. 14

1 General Information

Summary of the content on the page No. 15

General Information This chapter provides a general description of your power supply. This chapter also contains instructions for initial inspection, location and cooling for bench and rack operation, selecting the power-line voltage, and connecting your power supply to ac power. Safety Considerations This power supply is a Safety Class I instrument, which means that it has a protective earth terminal. That terminal must be connected to earth ground through a power source with a 3-wire grou

Summary of the content on the page No. 16

Chapter 1 General Information Options and Accessories 1 Options and Accessories Options Option ‘‘0E3’’ and ‘‘0E9’’ determine which power-line voltage is selected at the factory. The standard unit is configured for 115 Vac ± 10%, 47-63 Hz input voltage. For more information about changing the power-line voltage setting, see "Power-Line Voltage Selection", starting on page 22 in this page. Option Description 0E3 230 Vac ± 10%, 47-63 Hz input voltage 0E9 100 Vac ± 10%, 47-63 Hz input voltage 1CM

Summary of the content on the page No. 17

Chapter 1 General Information Description Description The Agilent E3632A DC power supply feature a combination of programming capabilities and linear power supply performance that makes it ideal for power systems applications. The power supply is programmable locally from the front panel or remotely over the GPIB and RS-232 interfaces. This power supply has two ranges, allowing more voltage at a lower current. The desired output range is selected from the front panel or over the remote inte

Summary of the content on the page No. 18

Chapter 1 General Information Description 1 When operated over the remote interface, the power supply can be both a listener and a talker. Using an external controller, you can instruct the power supply to set the output and to send the status data back over the GPIB or RS- 232. Capabilities include the following features: • Voltage and current programming • Voltage and current readback • Present and stored status readback • Programming syntax error detection • Complete self-test The front-pan

Summary of the content on the page No. 19

Chapter 1 General Information Description Warning Outputs can be floated to maximum of ±240 Vdc provided that the metal shorting bars without insulation are either replaced with insulated conductors or they are removed from the terminals so there is no operator access to the output conductors without insulation. All field wiring insulation must be adequate for the voltage present. The power supply is shipped with a detachable, 3-wire grounding type power cord. The ac line fuse is an extract

Summary of the content on the page No. 20

Chapter 1 General Information Installation 1 Installation Initial Inspection When you receive your power supply, inspect it for any obvious damage that may have occurred during shipment. If any damage is found, notify the carrier and the nearest Agilent Sales Office immediately. Warranty information is shown in the front of this manual. Keep the original packing materials in case the power supply has to be returned to Agilent Technologies in the future. If you return the power supply for ser


Alternative user manuals
# User manual Category Download
1 Agilent Technologies E3632A User manual Computer Accessories 45
2 Agilent Technologies 85225F User manual Network Card 0
3 Agilent Technologies 8720ET User manual Network Card 6
4 Agilent Technologies Agilent E5810A User manual Network Card 18
5 Agilent Technologies 11694A User manual Network Card 1
6 Agilent Technologies 85032B/E 50 User manual Network Card 4
7 Agilent Technologies 8752C User manual Network Card 9
8 Agilent Technologies 00281-90055 User manual Network Card 0
9 Agilent Technologies Agilent 82350B User manual Network Card 2
10 Agilent Technologies 8719ET User manual Network Card 2
11 Agilent Technologies N6315A User manual Network Card 0
12 Agilent Technologies HP 16500B User manual Network Card 4
13 Agilent Technologies J6800A User manual Network Card 6
14 Agilent Technologies N2610A User manual Network Card 10
15 Agilent Technologies N1022A User manual Network Card 4
16 Sony BTA-NW1A User manual Network Card 2
17 Sony BKMW-E3000 User manual Network Card 2
18 Sony AC-SQ950D User manual Network Card 0
19 Sony BBV RX100 User manual Network Card 3
20 Sony CLIE A-AVZ-100-11 User manual Network Card 1