ADTRAN DSU/CSU user manual

User manual for the device ADTRAN DSU/CSU

Device: ADTRAN DSU/CSU
Category: Network Card
Manufacturer: ADTRAN
Size: 0.06 MB
Added : 6/1/2013
Number of pages: 6
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for ADTRAN DSU/CSU. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with ADTRAN DSU/CSU.

For your convenience

If looking through the ADTRAN DSU/CSU user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual ADTRAN DSU/CSU on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual ADTRAN DSU/CSU to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
ADTRAN DSU/CSU User manual - Online PDF
Advertisement
« Page 1 of 6 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual ADTRAN DSU/CSU but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to ADTRAN DSU/CSU. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Section 61291006L2-5
Issue 2, June 1999
CLEI Code #D4D3MPY_ _ _
Model TROCU DP Preferred Option
®
Total Reach All-Rate DDS Dataport
Installation and Maintenance
CONTENTS
1. GENERAL ..................................................................... 1
2. OPTIONS ...................................................................... 2
3. INSTALLATION ........................................................... 3
4. TESTING ....................................................................... 3

Summary of the content on the page No. 2

1 2 ON 2. OPTIONS NOTE Select the appropriate OPTIONS and RATE using Do not use in SLC-96 Mode II unless unit is SW1 and faceplate switches as illustrated in Figure 3 provisioned through Digital System-6. and Figure 4. CAUTION NOTE Select only one option rate. Rate is selected on The TROCU DP must be used with an faceplate switch SW2 by pushing one or two appropriate TRDDS-R unit. switches to the right toward the inscribed rates. If either SW56 or 64 is selected, the secondary channel (SC) switc

Summary of the content on the page No. 3

In lieu of option switches, the TROCU DP Preferred When inserted into a powered up backplane the Option has been preprovisioned with feature settings TROCU DP and TRDDS-R will synchronize within 30 as indicated in Table 1. to 90 seconds. When synchronized, the SYNC LOSS indicator LED will turn Off. If synchronization cannot Table 1. Preprovisioning be achieved, check the T/R pair for an open circuit or Fg eature Settin short circuit condition, or load coils (see LED Indicators). LNatchingLoopba

Summary of the content on the page No. 4

As an enhancement to automated testing capability, TROCU DP TRDDS eliminates false error indication when invoking NIE, CSU, or DSU loopbacks immediately TRDDS-R X following release of OCU loopback. DSU/CSU X Open Loop TROCU DP Bidirectional Loopback Support The TROCU DP will execute a bidirectional loopback Bidirectional loopback when performing an OCU loopback at the TROCU DP as shown in Figure 5. If the TRDDS-R detects a Figure 7. TROCU DP Bidirectional Loopback bidirectional loopback durin

Summary of the content on the page No. 5

and manual switch settings by pressing the 6. DEPLOYMENT GUIDELINES momentary Alternate Provisioning (AP) switch The TROCU DP and TRDDS-R use technology located on the front panel. If the channel unit is designed to eliminate the need for repeaters and removed from the system, the unit retains previous concerns over impairments caused by typical noise and provisioning information in nonvolatile Random bridge tap. Table 2 describes cable loss for the Access Memory (RAM). TRDDS Nyquist frequency o

Summary of the content on the page No. 6

7. WARRANTY AND CUSTOMER SERVICE ADTRAN will replace or repair this product within 10 years from the date of shipment if it does not meet its published specifications or fails while in service (see: ADTRAN Carrier Networks Equipment Warranty, Repair, and Return Policy and Procedure, document: 60000087-10A). Contact Customer And Product Service (CAPS) prior to returning equipment to ADTRAN. For service, CAPS requests, or further information, contact one of the following numbers: ADTRAN Technical


Alternative user manuals
# User manual Category Download
1 ADTRAN 1000 User manual Network Card 1
2 ADTRAN 1xN User manual Network Card 0
3 ADTRAN 1200051L5 User manual Network Card 0
4 ADTRAN 1204006L1 User manual Network Card 0
5 ADTRAN 1000R Series User manual Network Card 0
6 ADTRAN 1200051L2 User manual Network Card 0
7 ADTRAN 1204002L1 User manual Network Card 0
8 ADTRAN 220 DDM, 3192 H2TU-C User manual Network Card 0
9 ADTRAN 1355 PWR User manual Network Card 0
10 ADTRAN 3000 HTU-C User manual Network Card 0
11 ADTRAN 25 User manual Network Card 0
12 ADTRAN 3010 HTU-C User manual Network Card 0
13 ADTRAN 3192 H2TU-C User manual Network Card 3
14 ADTRAN 239 T1 HDSL4 User manual Network Card 0
15 ADTRAN 3010 User manual Network Card 0
16 Sony BTA-NW1A User manual Network Card 2
17 Sony BKMW-E3000 User manual Network Card 2
18 Sony AC-SQ950D User manual Network Card 0
19 Sony BBV RX100 User manual Network Card 3
20 Sony CLIE A-AVZ-100-11 User manual Network Card 1