ADC HiGain H2TU-C-319 List 4E user manual

User manual for the device ADC HiGain H2TU-C-319 List 4E

Device: ADC HiGain H2TU-C-319 List 4E
Category: Network Card
Manufacturer: ADC
Size: 1.04 MB
Added : 4/21/2013
Number of pages: 88
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for ADC HiGain H2TU-C-319 List 4E. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with ADC HiGain H2TU-C-319 List 4E.

For your convenience

If looking through the ADC HiGain H2TU-C-319 List 4E user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual ADC HiGain H2TU-C-319 List 4E on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual ADC HiGain H2TU-C-319 List 4E to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
ADC HiGain H2TU-C-319 List 4E User manual - Online PDF
Advertisement
« Page 1 of 88 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual ADC HiGain H2TU-C-319 List 4E but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to ADC HiGain H2TU-C-319 List 4E. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

HiGain
HiGain
USER MANUAL
HiGain
HDSL2
H
2
T
U
*
C
3
L
1
4E 9
SETUP
M
L
O
B
D
K
E
STATUS
B
R
G
O
H2TU-C-319 List 4E
U
L
T
I
Product Catalog: H2TU-C-L4E
N
E
CLEI Code: VACHYVYG
B
R
G
I
N L
I
N
E
R
S
2
3
2
DCE

Summary of the content on the page No. 2

LTPH-UM-1049-02, Issue 2 Revision History of This Manual Issue Release Date Revisions Made 1 October 5, 2001 Initial release. 2 January 9, 2002 BERT update. Copyright January 9, 2002 © 2002 ADC DSL Systems, Inc. All rights reserved. Trademark Information ADC is a registered trademark of ADC Telecommunications, Inc. HiGain is a registered trademark of ADC DSL Systems, Inc. No right, license, or interest to such trademarks is granted hereunder, and you agree that no such right, license, or int

Summary of the content on the page No. 3

LTPH-UM-1049-02, Issue 2 Using This Manual USING THIS MANUAL The following conventions are used in this manual: • Monospace type indicates screen text.  Keys you press are indicated by small icons such as Y or ENTER . Key combinations to be pressed simultaneously are indicated with a plus sign as follows: CTRL + ESC .  Items you select are in bold.  Three types of messages, identified by icons, appear in text. Notes contain information about special circumstances. Cautions indicate the possi

Summary of the content on the page No. 4

Inspecting Shipment LTPH-UM-1049-02, Issue 2 iv January 9, 2002 H2TU-C-319 List 4E

Summary of the content on the page No. 5

LTPH-UM-1049-02, Issue 2 Table of Contents TABLE OF CONTENTS Overview ____________________________________________________________________________ 1 Features ..............................................................................................................................................1 Compatibility .....................................................................................................................................2 Applications ....................................

Summary of the content on the page No. 6

Table of Contents LTPH-UM-1049-02, Issue 2 Testing _____________________________________________________________________________ 52 System Alarms................................................................................................................................. 52 Alarm Option for the Digital Loop Carrier Feed .............................................................. 53 Retiring System Alarms......................................................................................

Summary of the content on the page No. 7

LTPH-UM-1049-02, Issue 2 List of Figures LIST OF FIGURES 1. H2TU-C-319 List 4E Front Panel ...................................................................................................................3 2. Installing the H2TU-C-319 List 4E into a Shelf .............................................................................................8 3. Logon Screen....................................................................................................................................

Summary of the content on the page No. 8

List of Tables LTPH-UM-1049-02, Issue 2 LIST OF TABLES 1. Front-Panel Description .................................................................................................................................. 4 2. Front-Panel Display Messages........................................................................................................................ 5 3. Navigational Keys for the HiGain HDSL2 Maintenance Terminal Screens ................................................ 12 4. Logo

Summary of the content on the page No. 9

LTPH-UM-1049-02, Issue 2 Overview OVERVIEW The H2TU-C-319 List 4E (H2TU-C) line unit is the Central Office (CO) side of a T1 transmission system. The HiGain HDSL2 product family is fully compliant with the HDSL2 standard ANSI T1.418. Providing full-rate T1 access using a single copper pair, HDSL2 is a cost-effective solution that offers an open architecture. The open architecture inherent in HDSL2 guarantees interoperability allowing simple and economic accommodation of network growth. HiGai

Summary of the content on the page No. 10

Overview LTPH-UM-1049-02, Issue 2  Configuration options – Selectable DS1 pre-equalizer – Bipolar Violation Transparency (BPVT) options – Bit Error Rate (BER) alarm – Power Back Off Network (PBON) and Power Back Off Customer (PBOC) options for configuring output levels – Loss of Signal/Alarm Indication Signal (LOS/AIS) payload alarm option – Remote provisioning ®  Compatible with HMS-358 Soneplex Wideband 3190 shelves only  Digital Data Service (DDS) latching loopback  Network Management a

Summary of the content on the page No. 11

LTPH-UM-1049-02, Issue 2 Front Panel FRONT PANEL Figure 1 shows the H2TU-C-319 List 4E front panel. Table 1 on page 4 describes the front-panel components. For pinout diagrams of the H2TU-C-319 List 4E card-edge connector and craft port, refer to “Appendix A - Specifications” on page 65. HiGain HDSL2 H 2 Front-panel display T U * List number C 3 L 1 4E 9 SETUP M S Status LED O E System option pushbuttons D L E STATUS B R G O Card handle U L T I (CLEI code and N E ECI bar code label on outside

Summary of the content on the page No. 12

Front Panel LTPH-UM-1049-02, Issue 2 Table 1. Front-Panel Description Front-Panel Feature Function Front-panel display Displays four-character status, provisioning, and alarm system messages. The front-panel display illuminates when power is initially applied. To conserve power the display only remains on for 5 minutes. Using the MODE or LBK pushbuttons reactivates the display and restarts the 5-minute timer. Refer to Table 2 on page 5 for a listing of the four-character messages. MODE and

Summary of the content on the page No. 13

LTPH-UM-1049-02, Issue 2 Front Panel Table 2 lists the front-panel display messages. The four-character display reports the code of an alarm, loopback, or diagnostic message and, in some cases, is followed by a second four-character message that modifies the first message with a value or current configuration setting. Table 2. Front-Panel Display Messages Message Full Name Description ALARM MESSAGES ACO Alarm Cut Off A system alarm has occurred, and has been retired to an ACO condition by pr

Summary of the content on the page No. 14

Front Panel LTPH-UM-1049-02, Issue 2 Table 2. Front-Panel Display Messages (Continued) Message Full Name Description LOOPBACK MESSAGES CLOC Customer Local Loopback Signal from customer is looped back to the customer at the H2TU-R. CREM Customer Remote Loopback Signal from customer is looped back to the customer at H2TU-C. NLOC Network Local Loopback DSX-1 signal is looped back to the network at the H2TU-C. NREM Network Remote Loopback DSX-1 signal is looped back to the network at the H2TU-R.

Summary of the content on the page No. 15

LTPH-UM-1049-02, Issue 2 Front Panel Table 2. Front-Panel Display Messages (Continued) Message Full Name Description (a) SYSTEM INFORMATION MESSAGES CODE xxxx Line Code: AMI or B8ZS The DS1 line code setting: Alternate Mark Inversion (AMI) or Bipolar with 8-Zero Substitution (B8ZS). FRM xxxx Frame: SF, ESF, or UNFR Defines the type of frame pattern being received from the DSX-1: SuperFrame (SF), Extended SuperFrame (ESF), or Unframed (UNFR). LATT xx Loop Attenuation The current loop atten

Summary of the content on the page No. 16

Installation LTPH-UM-1049-02, Issue 2 INSTALLATION Upon receipt of the equipment, inspect the contents for signs of damage. If the equipment has been damaged in transit, immediately report the extent of damage to the transportation company and to ADC. H2TU-C-319 CO shelf Figure 2. Installing the H2TU-C-319 List 4E into a Shelf When installing an H2TU-C in a chassis, be sure to wear an antistatic wrist strap. Avoid touching components on the circuit board. To comply with the intrabuilding wir

Summary of the content on the page No. 17

LTPH-UM-1049-02, Issue 2 Installation VERIFICATION Once the H2TU-C is installed, verify that it is operating properly. To do this, monitor the following:  Status LED  Status messages reported by the front-panel display (Table 2 on page 5 lists the status messages). Verification without an H2TU-R Remote Unit If there is no H2TU-R remote unit installed: 1 Verify that the H2TU-C powers up. The front-panel display illuminates and reports status messages. (See Table 2 on page 5 lists the messages.

Summary of the content on the page No. 18

Provisioning LTPH-UM-1049-02, Issue 2 PROVISIONING There are two provisioning methods:  Use the MODE and LBK pushbuttons on the front panel of the H2TU-C to: – Set system options – Reset the H2TU-C to its factory default settings for system options – Display system option settings (scroll mode) – Select system loopbacks – Select MTA test mode  Use a maintenance terminal, such as an ASCII terminal or a PC running terminal emulation software, connected to the H2TU-C craft port or an HMU craft

Summary of the content on the page No. 19

LTPH-UM-1049-02, Issue 2 Provisioning Resetting to Factory Default Values All user options for the H2TU-C, described in Table 5 on page 18, can be set to the factory default values using the MODE and LBK pushbuttons. To set the user options to their default values: 1 Press the LBK pushbutton for 6 seconds until the following message appears: DFLT NO 2 Press the LBK pushbutton until the DFLT NO message is displayed. The message changes to DFLT YES indicating the factory default values are now i

Summary of the content on the page No. 20

Provisioning LTPH-UM-1049-02, Issue 2 USING A MAINTENANCE TERMINAL Connecting to a Maintenance Terminal The craft port on the front panel allows you to connect the H2TU-C to a maintenance terminal (ASCII terminal or PC running a terminal emulation program). Once connected to a maintenance terminal, you can access the maintenance, provisioning, and performance screens. To connect to a maintenance terminal: 1 Connect a standard 9-pin terminal cable to the RS-232 craft port, as shown in Figure


Alternative user manuals
# User manual Category Download
1 ADC 19717-A User manual Network Card 0
2 ADC 500L User manual Network Card 0
3 ADC 400F User manual Network Card 0
4 ADC and 3 Doubler User manual Network Card 0
5 ADC 600F User manual Network Card 1
6 ADC Campus-REX RS Interface Card User manual Network Card 1
7 ADC ACE-142S/142V User manual Network Card 0
8 ADC Campus-REX2 RS User manual Network Card 9
9 ADC Carrier-Grade WiMAX Base Station WMX 5000 User manual Network Card 1
10 ADC Cross-Connect DSXi User manual Network Card 1
11 ADC CRA-C User manual Network Card 0
12 ADC D3LXC-SCA100 User manual Network Card 0
13 ADC DSX-4R (RZX3) User manual Network Card 1
14 ADC EDU-409 User manual Network Card 0
15 ADC DL3XR-SCA100 User manual Network Card 0
16 Sony BTA-NW1A User manual Network Card 2
17 Sony BKMW-E3000 User manual Network Card 2
18 Sony AC-SQ950D User manual Network Card 0
19 Sony BBV RX100 User manual Network Card 3
20 Sony CLIE A-AVZ-100-11 User manual Network Card 1