ADC H2TU-C-231 user manual

User manual for the device ADC H2TU-C-231

Device: ADC H2TU-C-231
Category: Network Card
Manufacturer: ADC
Size: 1.34 MB
Added : 4/21/2013
Number of pages: 74
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for ADC H2TU-C-231. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with ADC H2TU-C-231.

For your convenience

If looking through the ADC H2TU-C-231 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual ADC H2TU-C-231 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual ADC H2TU-C-231 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
ADC H2TU-C-231 User manual - Online PDF
Advertisement
« Page 1 of 74 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual ADC H2TU-C-231 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to ADC H2TU-C-231. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

2
HiGain
HiGain
USER MANUAL
H2TU-C-231 List 2 Line Unit
Product Catalog: H2TU-C-231-L2
CLEI: VACJDLYE

Summary of the content on the page No. 2

LTPH-UM-1109-01, Issue 1 Revision History of This Practice Revision Release Date Revisions Made 01 January 9, 2002 Initial release. Copyright January 9, 2002 © 2002 ADC DSL Systems, Inc. All rights reserved. Trademark Information ADC is a registered trademark of ADC Telecommunications, Inc. HiGain is a registered trademark of ADC DSL Systems, Inc. No right, license, or interest to such trademarks is granted hereunder, and you agree that no such right, license, or interest shall be asserted by yo

Summary of the content on the page No. 3

LTPH-UM-1109-01, Issue 1 Using This Manual USING THIS MANUAL The following conventions are used in this manual: • Monospace type indicates screen text.  Keys you press are indicated by small icons such as Y or ENTER . Key combinations to be pressed simultaneously are indicated with a plus sign as follows: CTRL + ESC .  Items you select are in bold.  Three types of messages, identified by icons, appear in text. Notes contain information about special circumstances. Cautions indicate the possib

Summary of the content on the page No. 4

Inspecting Shipment LTPH-UM-1109-01, Issue 1 iv January 9, 2002 H2TU-C-231 List 2

Summary of the content on the page No. 5

LTPH-UM-1109-01, Issue 1 Table of Contents TABLE OF CONTENTS Overview ____________________________________________________________________________ 1 Features ..............................................................................................................................................1 Compatibility .....................................................................................................................................2 Applications ....................................

Summary of the content on the page No. 6

Table of Contents LTPH-UM-1109-01, Issue 1 Testing _____________________________________________________________________________ 40 System Alarms................................................................................................................................. 40 Alarm Option for Digital Loop Carrier (DLC) Feed ........................................................ 41 Retiring System Alarms...........................................................................................

Summary of the content on the page No. 7

LTPH-UM-1109-01, Issue 1 List of Figures LIST OF FIGURES 1. H2TU-C-231 List 2 Front Panel.......................................................................................................................3 2. Installing the H2TU-C-231 List 2 into a Shelf.................................................................................................7 3. Logon Screen................................................................................................................................

Summary of the content on the page No. 8

List of Tables LTPH-UM-1109-01, Issue 1 LIST OF TABLES 1. Front-Panel Description................................................................................................................................... 4 2. Front-Panel Display Messages......................................................................................................................... 5 3. Navigational Keys for the Maintenance Terminal Screens ........................................................................

Summary of the content on the page No. 9

LTPH-UM-1109-01, Issue 1 Overview OVERVIEW The H2TU-C-231 List 2 line unit is the Central Office (CO) side of a T1 transmission system. The HiGain™ HDSL2 product family is fully compliant with the HDSL2 standard ANSI T1.418-2000. Providing full-rate T1 access using just a single copper pair, HDSL2 is a cost-effective solution that offers an open architecture. The open architecture inherent in HDSL2 guarantees interoperability allowing simple and economic accommodation of network growth. HiGain H

Summary of the content on the page No. 10

Overview LTPH-UM-1109-01, Issue 1 – Remote provisioning – Selectable loopback activation codes  Additional (Loopback Timeout) LBTO settings of 8 hours and 24 hours  Compatible with Small Cross-Section Shelf (SXSS) and equipment DS1 is used throughout this document to refer to either the remote unit’s DS1 interface or the line unit’s DSX-1 interface. COMPATIBILITY The H2TU-C-231 List 2 is designed to mount in 220 mechanics shelves. For a list of compatible shelves see “Appendix C - Compatibilit

Summary of the content on the page No. 11

LTPH-UM-1109-01, Issue 1 Front Panel FRONT PANEL Figure 1 shows the H2TU-C-231 List 2 front panel. Table 1 on page 4 describes the front-panel components. For a list of front-panel display messages, refer to “Front-Panel Display Messages” on page 5. For pinout diagrams of the H2TU-C card-edge connector and craft port, refer to “Appendix A - Specifications” on page 54. HiGain HDSL2 MODE SEL Front-panel display MODE and SEL pushbuttons SETUP STATUS Status LED H BRG 2 IN T LINE U • C DSX-1 access j

Summary of the content on the page No. 12

Front Panel LTPH-UM-1109-01, Issue 1 Table 1. Front-Panel Description Front-Panel Feature Function Front-panel display Displays four-character status, provisioning, and alarm system messages. The front-panel display illuminates when power is initially applied. To conserve power, the display only remains on for 5 minutes. Using the MODE or SEL pushbuttons reactivates the display and restarts the 5-minute timer. Refer to Table 2 on page 5 for a listing of the four-character messages. MODE and

Summary of the content on the page No. 13

LTPH-UM-1109-01, Issue 1 Front Panel Table 2 lists the front-panel display messages. The four-character display reports the code of a pertinent alarm, loopback, or diagnostic message and, in some cases, is followed by a second four-character message that modifies the first message with a value or current configuration setting. Table 2. Front-Panel Display Messages Message Full Name Description SYSTEM ALARM MESSAGES ACO Alarm Cutoff A system alarm has occurred and has been retired to an ACO condi

Summary of the content on the page No. 14

Front Panel LTPH-UM-1109-01, Issue 1 Table 2. Front-Panel Display Messages (Continued) Message Full Name Description NREM Network Remote Loopback DSX-1 signal is looped back to the network at the H2TU-R. RULB Remote Unit Loopback Dual loopback at the H2TU-R. SMJK Remote SmartJack Loopback DSX-1 signal is looped back to the network at the H2TU-R SmartJack module. DIAGNOSTIC MESSAGES A = xx Maximum Loop Attenuation The Attenuation (A) message appears followed by xx, where xx is the highest loop a

Summary of the content on the page No. 15

HLU-431 HiGain LINE UNIT PairGain LTPH-UM-1109-01, Issue 1 Installation INSTALLATION Upon receipt of the equipment, inspect the contents for signs of damage. If the equipment has been damaged in transit, immediately report the extent of damage to the transportation company and to ADC. H2TU-C-231 CO Shelf Figure 2. Installing the H2TU-C-231 List 2 into a Shelf When installing an H2TU-C 231 in a chassis, be sure to wear an antistatic wrist strap. Avoid touching components on the circuit board. To

Summary of the content on the page No. 16

Installation LTPH-UM-1109-01, Issue 1 VERIFICATION Once the H2TU-C-231 is installed, verify that it is operating properly. To do this, monitor the following:  Status LED (seeFigure 1onpage3)  Status messages reported by the front-panel display (see Table 2 on page 5) Verification without an H2TU-R Remote Unit If there is no H2TU-R remote unit installed: 1 Verify that the H2TU-C powers up. The front-panel display illuminates and reports status messages. (See Table 2 on page 5 for a list of mess

Summary of the content on the page No. 17

LTPH-UM-1109-01, Issue 1 Provisioning PROVISIONING There are two methods for provisioning:  Use the MODE and SEL pushbuttons on the front panel of the H2TU-C to: – Set system options – Reset the H2TU-C to its factory default settings for system options – Display system option settings (scroll mode) – Select system loopbacks  Use a maintenance terminal (VT100 terminal or a PC running terminal emulation software) connected to the H2TU-C craft port (or to an HMU craft port) to access the maintena

Summary of the content on the page No. 18

Provisioning LTPH-UM-1109-01, Issue 1 Resetting to Factory Default Values AlluseroptionsfortheH2TU-C-231List2(Table 6 on page 18) can be set to the factory default values using the MODE and SEL pushbuttons. To set the user options to their default values: 1 Press the SEL pushbutton for 6 seconds until the following message appears: DFLT NO 2 Press the SEL pushbutton while theDFLT NO message is displayed. The message changes toDFLT YES indicating the factory default values are now in effect and t

Summary of the content on the page No. 19

LTPH-UM-1109-01, Issue 1 Provisioning USING A MAINTENANCE TERMINAL Connecting to a Maintenance Terminal The craft port on the front panel allows you to connect the H2TU-C-231 to a maintenance terminal (ASCII terminal or PC running a terminal emulation program). Once connected to a maintenance terminal, you can access the maintenance, provisioning, and performance screens. To connect to a maintenance terminal: 1 Connect a standard 9-pin terminal cable to the RS-232 craft port (Figure 1onpage3) on

Summary of the content on the page No. 20

Provisioning LTPH-UM-1109-01, Issue 1 Most VT100 emulation programs support a print screen option. For Windows-based programs, such as Procomm or HyperTerminal, do the following: 1 Highlight the screen that you wish to print. 2 Click File,then Print. 3 In the Print dialog box, choose Selection as the Print Range. 4 Click OK to print. For printing procedures for other programs, contact the appropriate vendor. Menu bar Monitor Performance Event Log Config Inventory Report Rlogon Help +------------


Alternative user manuals
# User manual Category Download
1 ADC 19717-A User manual Network Card 0
2 ADC 500L User manual Network Card 0
3 ADC 400F User manual Network Card 0
4 ADC and 3 Doubler User manual Network Card 0
5 ADC 600F User manual Network Card 1
6 ADC Campus-REX RS Interface Card User manual Network Card 1
7 ADC ACE-142S/142V User manual Network Card 0
8 ADC Campus-REX2 RS User manual Network Card 9
9 ADC Carrier-Grade WiMAX Base Station WMX 5000 User manual Network Card 1
10 ADC Cross-Connect DSXi User manual Network Card 1
11 ADC CRA-C User manual Network Card 0
12 ADC D3LXC-SCA100 User manual Network Card 0
13 ADC DSX-4R (RZX3) User manual Network Card 1
14 ADC EDU-409 User manual Network Card 0
15 ADC DL3XR-SCA100 User manual Network Card 0
16 Sony BTA-NW1A User manual Network Card 2
17 Sony BKMW-E3000 User manual Network Card 2
18 Sony AC-SQ950D User manual Network Card 0
19 Sony BBV RX100 User manual Network Card 3
20 Sony CLIE A-AVZ-100-11 User manual Network Card 1