ADC EDU-409 user manual

User manual for the device ADC EDU-409

Device: ADC EDU-409
Category: Network Card
Manufacturer: ADC
Size: 0.57 MB
Added : 4/21/2013
Number of pages: 34
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for ADC EDU-409. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with ADC EDU-409.

For your convenience

If looking through the ADC EDU-409 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual ADC EDU-409 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual ADC EDU-409 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
ADC EDU-409 User manual - Online PDF
Advertisement
« Page 1 of 34 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual ADC EDU-409 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to ADC EDU-409. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

HiGain
HiGain
USER MANUAL
EDU-409
HiGain
DOUBLER
L
EDU-409 List 1 Doubler Unit
Product Catalog: 150-409-115-05
STATUS

Summary of the content on the page No. 2

150-409-115-05, Issue 5 Revision History of This Manual To order copies of this document, use document catalog number 150-409-115-05. Issue Release Date Revisions Made 01 August 14, 1998 Initial release 02 August 24, 1998 Modify Tables 1 and 2 03 March 26, 1999 Update Technical Specifications 04 January 26, 2000 Change practice title 05 March 1, 2002 ADC rebranding of document; no technical changes Copyright January 26, 2000 © 2000 ADC DSL Systems, Inc. All rights reserved. Trademark Informat

Summary of the content on the page No. 3

150-409-115-05, Issue 5 Using This Manual USING THIS MANUAL The following conventions are used in this manual: • Monospace type indicates screen text.  Keys you press are indicated by small icons such as Y or ENTER . Key combinations to be pressed simultaneously are indicated with a plus sign as follows: CTRL + ESC .  Items you select are in bold. Three types of messages, identified by icons, appear in text. Notes contain information about special circumstances. Cautions indicate the possibi

Summary of the content on the page No. 4

Unpack and Inspect Your Shipment 150-409-115-05, Issue 5 iv January 26, 2000 EDU-409 List 1

Summary of the content on the page No. 5

150-409-115-05, Issue 5 Table of Contents TABLE OF CONTENTS Overview _______________________________________________ 1 Features.................................................................................... 1 Applications ............................................................................. 2 Product Description ______________________________________ 5 Cover........................................................................................ 5 Front Panel ........................

Summary of the content on the page No. 6

List of Figures 150-409-115-05, Issue 5 LIST OF FIGURES 1. EDU-409 List 1 Front Panel..................................................................6 2. Installing the EDU-409 List 1 in a Remote Enclosure..........................8 3. HiGain Loopbacks...............................................................................10 4. Doubler Block Diagram ......................................................................11 5. AT&T 819 Enclosure ............................................

Summary of the content on the page No. 7

150-409-115-05, Issue 5 Overview OVERVIEW ® The HiGain EDU-409 List 1 List 1 is a low-power doubler unit that extends the range of a HiGain repeaterless G.703 transmission system. The doubler units are installed between any doubler-compatible HiGain E1 Line Unit (ELU) and HiGain E1 Doubler (EDU) or HiGain E1 Remote Unit (ERU). They allow 2.048 Mbps transmission over twice the normal High Capacity Digital Service (HCDS) range. Adding a doubler can double the HCDS range to approximately 7.32

Summary of the content on the page No. 8

Overview 150-409-115-05, Issue 5 APPLICATIONS HiGain doublers operate with any number of T1, Plain Old Telephone Service (POTS), Digital Data Service (DDS), or other HiGain systems sharing the same cable binder group. The EDU-409 List 1 has a range of up to 35 dB loss at 260 kHz on each of the four HDSL loops. A list of HDSL signal cable losses for various cable gauges at 260 kHz and 135 Ω is provided in Table 1. The table is applicable to HDSL cable pairs running between the ELU and the ED

Summary of the content on the page No. 9

150-409-115-05, Issue 5 Overview Table 2 lists the maximum number of EDU-409 List 1 doubler units that can be deployed as a function of the ELU and ERU that are used with it. Table 2. EDU-409 List 1 Circuit Ranges Maximum Number of EDU-409 List 1 Doublers Per Circuit ELU Model (a) Line Powered Remote Local Powered Remote ELU-319 List 5D 1 2 ELU-319 List 6D (b) ELU-319 List 5E 2 3 ELU-319 List 6E (a) Requires ERU-412 List 1D and List 2D. ERU-412 List 1E and 2E do not support local power. (b)

Summary of the content on the page No. 10

Overview 150-409-115-05, Issue 5 The physical location of the doublers is driven by the following three deployment rules: 1 Place the enclosures at the electrical limits, 35 dB, of each span. This places the first doubler at the 35 dB location, the second at 70 dB, and so on, allowing the maximum circuit range to be realized. Caution must be observed when pushing doubler spans to their 35 dB maximum range. Refer to ADC’s Technical Advisory #TA-015 on HiGain operating ranges and general dep

Summary of the content on the page No. 11

150-409-115-05, Issue 5 Product Description PRODUCT DESCRIPTION The EDU-409 List 1 List 1 includes:  An open-framed cover  A front panel featuring: – Status display – Configuration number COVER The open-framed cover reduces thermal stress and improves reliability allowing air to freely circulate over all components. The open cover also permits the doubler to be easily distinguished from the 239 T1 repeater. EDU-409 List 1 January 26, 2000 5

Summary of the content on the page No. 12

Product Description 150-409-115-05, Issue 5 FRONT PANEL Figure 1 shows the front panel of the EDU-409 List 1, and Table 3 describes the doubler unit components. EDU-409 HiGain DOUBLER L Status LED STATUS Configuration number label (located on side) Figure 1. EDU-409 List 1 Front Panel Table 3. Front Panel Components and Labels Name Function Status LED Indicates operational status of doubler. See Table 4 on page 9. Configuration Contains either a five-digit or six-digit warranty configuration nu

Summary of the content on the page No. 13

150-409-115-05, Issue 5 Installation INSTALLATION This section describes the compatibility and installation for the EDU-409 List 1. COMPATIBILITY The EDU-409 List 1 is compatible with the following ADC outdoor enclosures:  HRE-500, single-slot unit  HRE-458, 10-slot unit  HRE-819, 12-slot unit INSTALLING THE EDU-409 LIST 1 To install the EDU-409 List 1 in an enclosure, perform the following steps and refer to the enclosure installation manual for information about cabling, proper connecti

Summary of the content on the page No. 14

Installation 150-409-115-05, Issue 5 Figure 2. Installing the EDU-409 List 1 in a Remote Enclosure Some enclosures may require you to adjust the retaining bar located on the front of the enclosure to secure the unit. Refer to the appropriate ADC user manual for the enclosure. Once the EDU-409 List 1 is installed in the enclosure, the front panel Status LED flashes green if power is applied from an upstream line unit. When the loops on both sides of the EDU synchronize, the LED constantly glo

Summary of the content on the page No. 15

150-409-115-05, Issue 5 Alarms ALARMS The front panel of the EDU-409 List 1 contains a tri-color LED. The LED color and activity provides information on system functionality (see Table 4). Table 4. Front Panel Status Indicator LED Description Flashing Green once Indicates synchronization is being attempted between the per second EDU-409 List 1 and the upstream (network) module. Flashing Green more Indicates synchronization is being attempted between the than once per second EDU-409 List 1 and

Summary of the content on the page No. 16

Loopback Operation 150-409-115-05, Issue 5 LOOPBACK OPERATION When equipped with the EDU-409 List 1, a HiGain system can execute a number of loopback commands. The loopbacks can be initiated from the ELU craft port or from the ELU front-panel buttons. For more information about doubler loopback commands, refer to the appropriate ELU practices (see“Product Support” on page 23). All NDU loopbacks are towards the network. All CDU loopbacks are towards the customer. Figure 3 is a diagram of a Hi

Summary of the content on the page No. 17

150-409-115-05, Issue 5 Functional Description FUNCTIONAL DESCRIPTION HiGain uses the ADC Two-Binary, One-Quaternary (2B1Q) HDSL transceiver system to establish two full-duplex 1040 kbps data channels between the ELU and the ERU units. Each EDU-409 List 1 increases the maximum range by approximately 3.66 km (12,000 feet) of 0.51-mm wire or 2.74 km (9,000 feet) of 0.4-mm wire per doubler. A block diagram of the EDU-409 List 1 with pinouts is shown in Figure 4. The doubler unit power supply

Summary of the content on the page No. 18

Functional Description 150-409-115-05, Issue 5 DOUBLER ENCLOSURE CAPACITIES WITH FULL SOLAR LOAD The EDU-409 List 1 can be housed in a variety of outdoor enclosures manufactured by ADC and other vendors. The number of doublers used in any of the enclosures depends on the maximum outside ambient temperature. The doubler capacities for several of these standard enclosures is listed in Table 5 on page 13 and Table 6 on page 14. The capacities listed in Table 6 (for both indoor and outdoor enc

Summary of the content on the page No. 19

150-409-115-05, Issue 5 Functional Description The capacities listed for the indoor enclosures in Table 5 assume no solar load. The capacities listed for the outdoor enclosures in Table 6 assume a full solar load as described above. The “Recommended Slot Assignment for Maximum Capacity” column assigns slots according to the following thermal stress reduction rules: 1 Always leave at least one empty slot between adjacent doublers. The adjacency rule only applies to the left- and right-hand s

Summary of the content on the page No. 20

Functional Description 150-409-115-05, Issue 5 Table 6. Outdoor Enclosure Capacities with Full Solar Load EDU-409 Recommended Slot 239 T1 List 1 Assignment for Vendor Description Model No. Repeater Doubler Maximum Capacity Capacity Capacity AT&T Outdoor Dual 819 12 25 1, 3, 5, 9, 11, 13, 15, chamber 17, 19, 21, 23, 25 pole/wall (See Figure 5 on mount page 17) AT&T Outdoor 841 27A, B, C or 11 per 25 per 1, 3, 6, 8, 10, 11, 12, cabinet D shelf shelf/44 shelf/100 16, 18, 20, 23, 25 total tota


Alternative user manuals
# User manual Category Download
1 ADC 19717-A User manual Network Card 0
2 ADC 500L User manual Network Card 0
3 ADC 400F User manual Network Card 0
4 ADC and 3 Doubler User manual Network Card 0
5 ADC 600F User manual Network Card 1
6 ADC Campus-REX RS Interface Card User manual Network Card 1
7 ADC ACE-142S/142V User manual Network Card 0
8 ADC Campus-REX2 RS User manual Network Card 9
9 ADC Carrier-Grade WiMAX Base Station WMX 5000 User manual Network Card 1
10 ADC Cross-Connect DSXi User manual Network Card 1
11 ADC CRA-C User manual Network Card 0
12 ADC D3LXC-SCA100 User manual Network Card 0
13 ADC DSX-4R (RZX3) User manual Network Card 1
14 ADC DL3XR-SCA100 User manual Network Card 0
15 ADC DL3XR-FCA100 User manual Network Card 0
16 Sony BTA-NW1A User manual Network Card 2
17 Sony BKMW-E3000 User manual Network Card 2
18 Sony AC-SQ950D User manual Network Card 0
19 Sony BBV RX100 User manual Network Card 3
20 Sony CLIE A-AVZ-100-11 User manual Network Card 1