8e6 Technologies ER3-200 (5K02-56) user manual

User manual for the device 8e6 Technologies ER3-200 (5K02-56)

Device: 8e6 Technologies ER3-200 (5K02-56)
Category: Network Card
Manufacturer: 8e6 Technologies
Size: 5.6 MB
Added : 11/16/2013
Number of pages: 74
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for 8e6 Technologies ER3-200 (5K02-56). Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with 8e6 Technologies ER3-200 (5K02-56).

For your convenience

If looking through the 8e6 Technologies ER3-200 (5K02-56) user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual 8e6 Technologies ER3-200 (5K02-56) on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual 8e6 Technologies ER3-200 (5K02-56) to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
8e6 Technologies ER3-200 (5K02-56) User manual - Online PDF
Advertisement
« Page 1 of 74 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual 8e6 Technologies ER3-200 (5K02-56) but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to 8e6 Technologies ER3-200 (5K02-56). If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Enterprise Reporter
QUICK START
GUIDE
Model: ER
ER3-100 (5K02-55), ER3-200 (5K02-56), ERS-100 (5K02-51),
ERS-200 (5K02-52), ERH-100 (5K02-61), ERH-200 (5K02-24)
Release: 5.0.00 / Updated: 01.07.09
®

Summary of the content on the page No. 2

8e 6 e nterprise r eporter Quick s artt Guide © 2009 8e6 Technologies. All rights reserved. This document may not, in whole or in part, be copied, photocopied, reproduced, translated, or reduced to any elec- tronic medium or machine readable form without prior written consent from 8e6 Technologies. Every effort has been made to ensure the accuracy of this document. However, 8e6 Technologies makes no war- ranties with respect to this documentation and disclaims any implied warranties of merchant

Summary of the content on the page No. 3

Contents R e e R nte R p ise RepoRteR i R nt oduCtion ......................................................1 About this Document ....................................................................................................................2 Conventions Used in this Document ...........................................................................................2 s R e C vi e i R nfo tionma ..................................................................................3 p RR elimina

Summary of the content on the page No. 4

“” h s R e R ve s peCifiCtionsa ......................................................................51 Physical Specifications ...............................................................................................................51 Hardware Component Specifications ........................................................................................52 Internal Product Specifications ..................................................................................................52

Summary of the content on the page No. 5

R e e nteRR p ise RR epo R te i ntRoduCtion Thank you for choosing to evaluate the 8e6 Technologies ER Enterprise Reporter. The ER is designed to readily obtain information about end users’ Internet activity via log files (text files containing Web access data) from a source device such as the 8e6 R3000 Enterprise Filter. ER “H” server models include RAID technology for fault tolerance and high perfor- mance. The ER is comprised of the ER server and client application. Once the ER server is c

Summary of the content on the page No. 6

About this Document This document is divided into the following sections: • Introduction - This section is comprised of an overview of the ER product and how to use this document • Service Information - This section provides 8e6 Technologies contact information • Preliminary Setup Procedures - This section includes instructions on how to physi- cally set up the ER in your network environment • Install the Server - This section explains how to configure the ER for reporting • Conclusion - This s

Summary of the content on the page No. 7

s R e C vi e i R nfo tionma The user should not attempt any maintenance or service on the unit beyond the proce- dures outlined in this document. Any initial hardware setup problem that cannot be resolved at your internal organiza- tion should be referred to an 8e6 Technologies solutions engineer or technical support representative. 8e6 Corporate Headquarters (USA) Local : 714.282.6111 Domestic US : 1.888.786.7999 International : +1.714.282.6111 8e6 Taiwan Taipei Local : 2397-0300 Domes

Summary of the content on the page No. 8

p RR elimina y s etup p RoCR edu es Unpack the Unit from the Carton Inspect the packaging container for evidence of mishandling during transit. If the packag- ing container is damaged, photograph it for reference. Carefully unpack the unit from the carton and verify that all accessories are included. Save all packing materials in the event that the unit needs to be returned to 8e6 Tech- nologies. The carton should contain the following items: • 1 Enterprise Reporter (ER) • 1 Bezel to be instal

Summary of the content on the page No. 9

Select a Site for the Server The server operates reliably within normal office environmental limits. Select a site that meets the following criteria: • Clean and relatively free of excess dust. • Well-ventilated and away from sources of heat, with the ventilating openings on the server kept free of obstructions. • Away from sources of vibration or physical shock. • Isolated from strong electromagnetic fields and noise caused by electrical devices such as elevators, copy machines, air conditio

Summary of the content on the page No. 10

Install the “H” Server Bezel Before rack mounting an “H” server, the bezel should be installed on the front end of the chassis. This portion of the installation process requires you to unpack the unit and bezel. NOTE: The bezel has been packaged separately from the unit to prevent dam- age during shipping. Front of bezel Outside of left inner rail Inside front end of U-shaped handle on left inner rail Inner left rail attached to chassis Pin on right side of bezel 6 8e 6 e nterprise r

Summary of the content on the page No. 11

A. Remove the plastic wrapping from the left and right U-shaped chassis rail handles. B. On one side of the chassis (left or right), un- screw the inner rail from the chassis. C. Slide the loosened inner rail slightly backwards to release it from the clips at the side of the chassis, and then lay it down beside the chas- sis, with the inside of the rail facing up. D. On the inner rail that is still attached to the chassis, insert the bezel pin into the bottom hole of the U-shaped chass

Summary of the content on the page No. 12

F. Return the loosened inner rail to its upright po- sition and insert the bezel pin into the bottom hole of the U-shaped handle. G. Slide the inner rail forward beneath the clips to lock it in place. H. Screw the inner rail back on the chassis. I. After it is installed, the bezel should drop down when it is gently tugged forward and down- ward. The bezel should remain upright when raised up and closed. 8 8e 6 e nterprise r terepor Q uick s tart G uide

Summary of the content on the page No. 13

Rack Mount the Server Rack Setup Precautions Warning: Before rack mounting the server, the physical environment should be set up to safely ac- commodate the server. Be sure that: • The weight of all units in the rack is evenly distributed. Hazardous conditions may be created by an uneven weight distribution. • The rack will not tip over when the server is mounted, even when the unit is fully extended from the rack. • For a single rack installation, stabilizers are attached to the rack. • For m

Summary of the content on the page No. 14

Rack Mount Instructions for non-“H” Servers Rack Setup Suggestions • Determine the placement of each component in the rack before you install the rails. • Install the heaviest server components on the bottom of the rack first, and then work up. Identify the Sections of the Rack Rails You should have received two rack rail assemblies with the 8e6 server unit. Each of these assemblies consists of two sections: An inner fixed chassis rail that secures to the unit (A), and an outer fixed rack ra

Summary of the content on the page No. 15

Install the Chassis Rails Position the fixed chassis rail sections you just removed along the side of the server chassis making sure the five screw holes line up. Note that these two rails are left/right specific. Screw the rail securely to the side of the chassis. Repeat this procedure for the other rail on the other side of the chassis. You will also need to attach the rail brackets when installing into a Telco rack. Locking Tabs: As you have seen, both chassis rails have a locking tab, wh

Summary of the content on the page No. 16

Install the Server into the Rack You should now have rails attached to both the chassis and the rack unit. The next step is to install the server chassis into the rack. Do this by lining up the rear of the chassis rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping the pressure even on both sides (you may have to depress the locking tabs when inserting). Installing the Server into a Telco Rack If you are installing the 8e6 server unit into a Telco t

Summary of the content on the page No. 17

Identify the Sections of the Rack Rails You should have received two rack rail assemblies with the 8e6 server unit. Each of these assemblies consists of two sections: An inner fixed chassis rail that secures to the unit (A), and an outer fixed rack rail that secures directly to the rack itself (B). Two pairs of short brackets to be used on the front side of the outer rails are also included. 8e 6 e nterprise r terepor Q uick s tart G uide 

Summary of the content on the page No. 18

Rack Mount Instructions for “H” Servers Rack Setup Suggestions • Determine the placement of each component in the rack before you install the rails. • Install the heaviest server components on the bottom of the rack first, and then work up. Install the Inner Rails Both the left and right side inner rails have been pre-attached to the chassis. Proceed to the next step. Install the Outer Rails Begin by measuring the distance from the front rail to the rear rail of the rack. Attach a short brac

Summary of the content on the page No. 19

Install the Server into the Rack You should now have rails attached to both the chassis and the rack unit. The next step is to install the server chassis into the rack. Do this by lining up the rear of the chassis rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping the pressure even on both sides (you may have to depress the locking tabs when inserting). When the server has been pushed completely into the rack, you should hear the locking tabs “clic

Summary of the content on the page No. 20

Installing the Server into a Telco Rack If you are installing the 8e6 server unit into a Telco type rack, follow the directions given on the previous page for rack installation. The only difference in the installation proce- dure will be the positioning of the rack brackets to the rack. They should be spaced apart just enough to accommodate the width of the Telco rack. 6  8e 6 e nterprise r terepor Q uick s tart G uide


Alternative user manuals
# User manual Category Download
1 8e6 Technologies ERH-200 (5K02-24) User manual Network Card 0
2 8e6 Technologies ER3-100 (5K02-55) User manual Network Card 0
3 8e6 Technologies Enterprise Filter R3000IR User manual Network Card 0
4 8e6 Technologies Enterprise Reporter HL-022-002 User manual Network Card 0
5 8e6 Technologies ERS-200 (5K02-52) User manual Network Card 0
6 8e6 Technologies ERH-100 (5K02-61) User manual Network Card 0
7 8e6 Technologies Enterprise Filter R3000 User manual Network Card 0
8 8e6 Technologies Enterprise Reporter HL-002-002 User manual Network Card 0
9 8e6 Technologies ER 4.0 User manual Network Card 0
10 8e6 Technologies Threat Analysis Reporter TAR User manual Network Card 0
11 8e6 Technologies ProxyBlocker User manual Network Card 0
12 8e6 Technologies Threat Analysis Reporter TAR HL/SL/MSA User manual Network Card 0
13 8e6 Technologies Threat Analysis Reporter TAR 1.0 User manual Network Card 0
14 8e6 Technologies 3 User manual Network Card 0
15 8e6 Technologies Enterprise Filter Authentication R3000 User manual Network Card 0
16 Sony BTA-NW1A User manual Network Card 2
17 Sony BKMW-E3000 User manual Network Card 2
18 Sony AC-SQ950D User manual Network Card 0
19 Sony BBV RX100 User manual Network Card 3
20 Sony CLIE A-AVZ-100-11 User manual Network Card 1