Accusys RAID Controller ACS-77100 user manual

User manual for the device Accusys RAID Controller ACS-77100

Device: Accusys RAID Controller ACS-77100
Category: Network Card
Manufacturer: Accusys
Size: 1.08 MB
Added : 10/13/2014
Number of pages: 30
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Accusys RAID Controller ACS-77100. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Accusys RAID Controller ACS-77100.

For your convenience

If looking through the Accusys RAID Controller ACS-77100 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Accusys RAID Controller ACS-77100 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Accusys RAID Controller ACS-77100 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Accusys RAID Controller ACS-77100 User manual - Online PDF
Advertisement
« Page 1 of 30 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Accusys RAID Controller ACS-77100 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Accusys RAID Controller ACS-77100. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1















ACS-77100 RAID controller
User Manual

















Summary of the content on the page No. 2

User’s Manual Preface ..........................................................................................................................3 Notice......................................................................................................................3 Trademarks..............................................................................................................3 About This document..............................................................................

Summary of the content on the page No. 3

User’s Manual 5.1. Firmware updating steps ..................................................................................23 6. Trouble Shooting.......................................................................................................26 7. FAQ..........................................................................................................................27 8. Contact Accusys.........................................................................................

Summary of the content on the page No. 4

User’s Manual Preface Notice Product features and specifications described in this manual are subject to change without notice. The manufacturer shall not be liable for any damage, or for the loss of information resulting from the performance or use of the information contained herein. Trademarks Accusys and the names of Accusys products and logos referenced herein are trademarks and/or service marks or registered trademarks and/or service marks of Accusys, Inc. Microsoft, Windows

Summary of the content on the page No. 5

User’s Manual About This document This document discusses how to properly design your RAID solution when using the ACS-77100 RAID controller, and guides you to configure the RAID controller. Customer should have a working knowledge of RAID planning and data storage. Symbols used in this document Important information that users should be aware of is indicated with the following icons: Caution This icon indicates the existence of a potential hazard that could result in per

Summary of the content on the page No. 6

User’s Manual 1. Introduction to the ACS-77100 1.1. Overview The ACS-77100 RAID controller provides RAID 0 (striping), RAID 10 (Striping and mirroring) and RAID 5 (striping with parity) for you to construct a disk array optimized for performance or reliability. By connecting the SATA cables between the ACS-77100 and the disks, a RAID solution can be easily built. The ACS-77100 controller is equipped with Java-based GUI (graphical user interface) monitoring program, by which users ca

Summary of the content on the page No. 7

User’s Manual 1.3. Understanding RAID Levels 1.3.1. RAID 0 (striping) RAID 0 links each drive in the array to from one large drive. Storage capacity is determined by the smallest drive in the array. This capacity is then applied to format all other drive in the array. When using a 40GB, 50GB and a 60GB drive in a RAID 0 array, your system will have, in effect, one 120GB drive (40GB x 3) The diagram above represents the writing of data on a RAID 0 array composed of four disks

Summary of the content on the page No. 8

User’s Manual 1.3.2. RAID 10 (striping and mirroring) RAID 0+1 combines mirroring and striping functions on a minimum of four hard disks. Mirroring provides full redundancy and protects data in case of multiple drive failure (providing that data on one of each mirrored pair of drives is intact). The diagram shown represents the writing of data on a RAID 0+1 array composed of four DISKS connected to the controller. The controller creates two matching RAID 0 arrays on four DISKS

Summary of the content on the page No. 9

User’s Manual 1.3.3. RAID 5 (striping with parity) and RAID 5+hot spare RAID 5 uses a mathematical expression that compares data from three drives and calculates a fourth piece of data called “parity” which is saved on a fourth drive. Should one of the drives failed, parity data can be used to rebuild the failed data. Under RAID 5, parity data is stored across all drives in the array. This maximizes the amount of storage capacity available from all drives in the array while still pr

Summary of the content on the page No. 10

User’s Manual 2. Build a RAID Solution This chapter covers the installation of the ACS-77100. The customers will be guided to using ACS-77100 to build a RAID solution. 2.1. Hardware Requirement: ACS-77100 RAID controller Backplane or Disk I/O board Disk carriers (with LED Indicators) Power supply Fan module Chassis Other materials SATA disk cable Header to DB9 cable SATA to eSATA internal cable Selector (with header connector + cable) 9 http://www.accu

Summary of the content on the page No. 11

User’s Manual 2.2. LCD Panel Operations The LCD messages are displayed on the screen of LCD panel for system status. Access LED Power LED ▲: Scroll up button ▼: Scroll down button ENT: Enter button ESC: ESC button Scroll up button: to scroll up message data. Scroll down button: to scroll down message data. Enter button: to confirm or enter your selection. ESC button: back to the top layer of message data. 10 http://www.accusys.c

Summary of the content on the page No. 12

User’s Manual 3. Set up the RAID solution This chapter covers the configuration of the ACS-77100. Through an easy process, the customers will be guided to configure the ACS-77100 through the following steps: Step 1 3.1. Setting the RAID level – The ACS-77100 is per-configured at RAID level 5, but you have the option of customizing your RAID level in this step Step 2 3.2. Creating an Array – The disks in ACS-77100 will be used to create an array, by which you can partition and use t

Summary of the content on the page No. 13

User’s Manual 3.1.1 RAID Level configurations RAID Level 5 RAID Level 0 Pin1-3 is open. Pin1-3 is short. Pin5-7 is open. Pin5-7 is short. RAID Level 10 RAID Level 5 + spare Pin1-3 is short. Pin1-3 is open. Pin5-7 is open. Pin5-7 is short. Note If the RAID level is not matched between the disk setting and the RAID level selector setting, the LCD will display the following two messages alternatively: (1) “RAID level” “Unmatched” (2) “Current: R(X)” (i

Summary of the content on the page No. 14

User’s Manual 3.2. Creating an Array 3.2.1 Enable/Disable Over 2TB capacity ACS-77100 supports over 2TB capacity. The steps below will guide you to enable/disable over 2TB capacity. 1. Select scroll button to find the capacity setting item on LCD panel. (P.18, 4.1.2. Set over 2TB capacity Messages ) 2. Press the ENT button, and select (YES) or (NO) by the scroll buttons. Note If you want to create the array with over 2TB capacity, the setting must be finished before to create an a

Summary of the content on the page No. 15

User’s Manual Note The device over 2TB capacity should be supported by Operation System (e.g. Windows Vista). Please refer to section 3.5. Formatting and Partitioning the ACS-77100 to partition the device. 3.3. Setting the Time and Date by LCD To change the time and date on the LCD, press and hold the ENT button for five seconds. Release the button to display the date and time setting screen. To adjust the time and date values, use the Scroll buttons to change the values. (Figu

Summary of the content on the page No. 16

User’s Manual 3.4. Connecting ACS-77100 to the Host computer 1. Follow the steps on page 11, 3.1. Setting the RAID Level and 13, 3.2. Create an Array to establish a RAID. 2. Connect an end of the eSATA cable into the eSATA port on the ACS-77100 RAID subsystem. 3. Connect the other end of the eSATA cable into the eSATA port on the host computer. It will take a few seconds for the host computer to recognize the drive for it to appear in My Computer or on the desktop. The ACS-771

Summary of the content on the page No. 17

User’s Manual 4. Windows operation system will list all the hard drives that are installed on the system. Locate the ACS-77100 drive that is represented by the icon. Right click the icon and select Initialize. 5. In the drive box to the right shows Unallocated, right click and select New Partition. (Figure 3.5.1.B) 6. The New Partition Wizard dialog box will appear, click Next to continue. (Figure 3.5.1.C) 7. After selecting partition type, specifying partition size and assign

Summary of the content on the page No. 18

User’s Manual 3.5.2. Formatting drive over 2TB capacity on Windows Vista The steps below will guide you to format a drive over 2TB capacity on Window Vista. 1. Right click Computer and click Manage. 2. From the Computer Management window, select Disk Management. 3. Windows operation system will list all the hard drives that are installed on the system. Locate the ACS-77100 drive that is represented by the icon. Right click the icon and select Initialize Disk. 4. The Initialize Di

Summary of the content on the page No. 19

User’s Manual 4. Management 4.1. LCD displayed Messages The status of the ACS-77100 can be viewed through the LCD display. By using the scroll buttons to scroll through the messages, the following information is available. RAID level and capacity Disk drive model Disk capacity Controller firmware version Controller serial number Fan and temperature status 4.1.1. Booting Messages LCD Display Message RAID Box ACS-77100 is booting Boot RAID Box ACS-77100 is i

Summary of the content on the page No. 20

User’s Manual 4.1.3. Initialization Messages LCD Display Message Create New RAID? Create a new RAID. No (Yes) RAID INIT XX.X % New array being created. Total: XXXX GB RAID Init 100 % RAID Initialization completed successfully. XXXX GB INIT OK! LCD Display Message Disk X failed during the initialization. The initialization RAID INIT Failed cannot proceed. DX offline Too many bad sectors in Disk X, initialization cannot RAID INIT Failed proceed. D


Alternative user manuals
# User manual Category Download
1 Accusys eXpeRAID User manual Network Card 0
2 Accusys ACS-61000/61010 User manual Network Card 0
3 Accusys ACS-61100 User manual Network Card 0
4 Sony BTA-NW1A User manual Network Card 2
5 Sony BKMW-E3000 User manual Network Card 2
6 Sony AC-SQ950D User manual Network Card 0
7 Sony BBV RX100 User manual Network Card 3
8 Sony CLIE A-AVZ-100-11 User manual Network Card 1
9 Sony BTA-NW1 User manual Network Card 11
10 Sony AC-NWUM50 User manual Network Card 1
11 Sony AR-B1474 User manual Network Card 2
12 Sony BKM-FW32 User manual Network Card 1
13 Sony 4000CL-MAV-PBIO User manual Network Card 1
14 Sony FA-ST1AM User manual Network Card 0
15 Sony MVC-FDR3/FDR3E User manual Network Card 1