Bard Mfg. Co.W17A user manual

User manual for the device Bard Mfg. Co.W17A

Device: Bard Mfg. Co.W17A
Category: Air Conditioner
Manufacturer: Bard
Size: 0.26 MB
Added : 12/21/2013
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bard Mfg. Co.W17A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bard Mfg. Co.W17A.

For your convenience

If looking through the Bard Mfg. Co.W17A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bard Mfg. Co.W17A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bard Mfg. Co.W17A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bard Mfg. Co.W17A User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bard Mfg. Co.W17A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bard Mfg. Co.W17A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

THE WALL-MOUNT™ AIR CONDITIONERS - 9.0 EER, (60HZ)
Models W17A to W60A
GREEN REFRIGERANT
1.5 to 5 Ton (16,400 to 55,000 Btuh)
R-410A
Right Side Control Panel 60Hz
The Bard Wall-Mount Air Conditioner is a self contained energy efficient
system, which is designed to offer maximum indoor comfort at a minimal
cost without using valuable indoor floor space or outside ground space.
This unit is the ideal product for versatile applications such as: new
construction, modular offices, school moderniz

Summary of the content on the page No. 2

Capacity and Efficiency Ratings MODELS W17A1 / W18A1 W24A1 W30A1 W36A1 W42A1 W48A1 W60A1 10 6,40020 4,00 20 9,60 30 5,40 40 1,00 40 7,00 55,00 Cooling Capacity BTUH 1 EER 2 90 .20 90 .0 90 .0 90 .0 90 .2 90 .0 9.0 1 Capacity is certified in accordance with ANSI/ARI Standard 390-2003. 2 EER = Energy Efficiency Ratio and is certified in accordance with ANSI/ARI Standard 390-2003. All ratings based on fresh air intake being 100% closed (no outside air introduction). Specifications 1-1/2 Ton thr

Summary of the content on the page No. 3

Ventilation System Packages Bard Wall-Mounts are designed to provide optional ventilation packages to meet all of your ventilation and indoor air quality requirements. All units are equipped with a barometric fresh air damper as the standard ventilation package. All ventilation packages can be built-in at the factory or field-installed at a later date. BAROMETRIC FRESH AIR DAMPER - BFAD STANDARD The barometric fresh air damper is a standard feature on all models. It is installed on the

Summary of the content on the page No. 4

Form No. S3397-1112 Supersedes S3397-712 Page 4 of 12 Commercial Room Ventilator Performance Data - CRV-2 W17A/W18A & W24A TOTAL AND VENTILATION AIRFLOW 1100 1000 900 800 700 Total Air 0 ESP Total Air .15 ESP 600 Total Air .3 ESP Vent Air 0 ESP 500 Vent Air .15 ESP Vent Air .3 ESP 400 300 200 100 0 AB C D E F Vent Position Commercial Room Ventilator Performance Data - CRVS-3 and CRVP-3 W30A & W36A HIGH SPEED TOTAL AND VENTILATION AIRFLOW W30A & W36A LOW SPEED TOTAL AND VENTILATION AIRFLOW 1200 1

Summary of the content on the page No. 5

Form No. S3397-1112 Supersedes S3397-712 Page 5 of 12 Commercial Room Ventilator Performance Data - CRVS-5 and CRVP-5 Commercial Room Ventilator Performance Data - CRVS-5 and CRVP-5 W42A & W48A HIGH SPEED TOTAL AND VENTILATION AIRFLOW W60A HIGH SPEED TOTAL AND VENTILATION AIRFLOW 2200 2100 2100 2000 2000 1900 1900 1800 1800 1700 1700 1600 1600 1500 1500 1400 1400 1300 Total Air 0 ESP Total Air 0 ESP 1300 1200 Total Air .2 ESP Total Air .2 ESP 1200 Total Air .4 ESP 1100 Total Air .4 ESP 1100 Vent

Summary of the content on the page No. 6

Performance and Application Data- ERVF-A2 SUMMER COOLING PERFORMANCE (INDOOR DESIGN CONDITIONS 75°DB/62°WB) Ambient VENTILATION RATE -- 250 CFM VENTILATION RATE -- 225 CFM VENTILATION RATE -- 200 CFM O.D. 62% EFFICIENCY 63% EFFICIENCY 63% EFFICIENCY DB/ WB F VLT VLS VLL HRT HRS HRL VLT VLS VLL HRT HRS HRL VLT VLS VLL HRT HRS HRL 75 510 19285 1014 3272 3952 0287 217 07271 2838 4461 7548 5920 1690 5460 4830 0662 0148 08 192 105 70 080 10 802 10 52 02 507 02 77 28 70 28 41 59140 59 60 48060 48 42

Summary of the content on the page No. 7

Form No. S3397-1112 Supersedes S3397-712 Page 7 of 12 Performance and Application Data- ERVF-*3 Performance and Application Data- ERVF-*5 SUMMER COOLING PERFORMANCE SUMMER COOLING PERFORMANCE (INDOOR DESIGN CONDITIONS 75°DB/62°WB) (INDOOR DESIGN CONDITIONS 75°DB/62°WB) Ambient VENTILATION RATE -- 400CFM VENTILATION RATE -- 325 CFM VENTILATION RATE -- 250 CFM Ambient VENTILATION RATE 450 CFM VENTILATION RATE 375 CFM VENTILATION RATE 300 CFM O.D. 63% EFFICIENCY 64% EFFICIENCY 65% EFFICIENCY O.D.

Summary of the content on the page No. 8

Electrical Specifications Single Circuit Dual Circuit 3 Minimum 1 Maximum 2 Field Rated No. Field 3 Minimum 1 Maximum 2 Field 2 Ground 2 Ground Circuit External Fuse Power Model Volts Power Circuit External Fuse Power Wire Size Wire Ampacity or Ckt. Brkr. Wire Size and Phase Circuits Ampacity or Ckt. Brkr. Wire Size Ckt. A Ckt. B Ckt. A Ckt. B Ckt. A Ckt. B Ckt. A Ckt. B W17A1/W18A1 - A00, A0Z 1 16 20 12 12 A05 1 30 30 10 10 230/208-1 A08 1 46 50 8 10 A10 1 56 60 6 10 W24A1 - A00, A0Z 21 30 10

Summary of the content on the page No. 9

Indoor Blower Performance - CFM at Rated Volts W17A1 W30A1 W42A1 W24A1 W60A1 ESP W18A1 W36A1 W48A1 in H O 2 High Speed Low Speed Single Speed High Speed Low Speed High Speed Low Speed High Speed Low Speed Dry/Wet Coil Dry/Wet Coil Dry/Wet Coil Dry/Wet Coil Dry/Wet Coil Dry/Wet Coil Dry/Wet Coil Dry/Wet Coil Dry/Wet Coil 0595 25/8865 70/6515 020/9715 395/13190 50/9310 885/18010 650/16020 200/200 1600/145 .5 180 75/8465 50/6390 60/9015 340/12795 30/9110 770/16610 550/15025 100/190 1525/137 .5 28

Summary of the content on the page No. 10

Cooling Application Data - Outdoor Temperature 1 1 1 1 1 D.B./W.B. Cooling o o o o o o o o o o Model 75 F 80 F 85 F 90 F 95 F 100 F 105 F 110 F 115 F 120 F Capacity 2 2 2 2 2 75/ Total Cooling 17,500 16,700 15,900 15,100 14,300 13,600 12,900 12,200 11,600 10,800 13,900 13,500 13,200 12,800 12,500 12,200 11,800 11,500 11,100 10,700 62 Sensible Cooling W17A1 80/ Total Cooling 18,600 18,100 17,600 17,000 16,400 15,800 15,200 14,500 13,900 13,100 W18A1 67 Sensible Cooling 13,400 13,200 13,000 12,80

Summary of the content on the page No. 11

Air Conditioning Wall-Mount Model Nomenclature W 36 A 1 A 10 X X X X X X SERIES | | CONTROL MODULES (See Chart Below) REVISION KW 1 TYPE NOMINAL | COIL OPTIONS Air Conditioner CAPACITY | X - Standard 17 - 1½ Ton 1 - Phenolic Coated Evaporator COLOR OPTIONS 18 - 1½ Ton Specialty Products 2 VENTILATION OPTIONS 2 - Phenolic Coated Condenser X - Beige (Standard) 24 - 2 Ton (Non-Standard) (See Table Below) 3 - Phenolic Coated Evaporator 1 - White 30 - 2½ Ton and Condenser 4 - Bucke

Summary of the content on the page No. 12

Clearances Required for Service Access Minimum Clearances Required to and Adequate Condenser Inlet Airflow Combustible Materials SUPPLY AIR DUCT MODELS LEFT SIDE RIGHT SIDE MODELS1 CABINET FIRST THREE FEET W" 17A, W18A, W24A, W30A, W36A1" 5 20 W" 17A, W18A, W24A 0" 0 W" 42A, W48A, W60A 2" 0 20 W" 30A, W36A 1" /4 0 NOTE: For side by side installation of two (2) WA models there W" 42A, W48A, W60A 1" /4 0 must be 20" between units. This can be reduced to 15" by using a WL model (left side compress


Alternative user manuals
# User manual Category Download
1 Bard Mfg. Co.P1136A1 User manual Air Conditioner 24
2 Bard Mfg. Co.HA4S3KA User manual Air Conditioner 3
3 Bard Mfg. Co.HL5S2KA User manual Air Conditioner 4
4 Bard 357-93-E User manual Air Conditioner 4
5 Bard Mfg. Co.W12A1 User manual Air Conditioner 2
6 Bard Mfg. Co.w17a2 User manual Air Conditioner 14
7 Bard Mfg. Co.P1130A1 User manual Air Conditioner 0
8 Bard Mfg. Co.HL4S2KA User manual Air Conditioner 1
9 Bard Mfg. Co.W18L1 User manual Air Conditioner 0
10 Bard Mfg. Co.W30L1 User manual Air Conditioner 1
11 Bard Mfg. Co.W42A1 User manual Air Conditioner 4
12 Bard Mfg. Co.W24L1 User manual Air Conditioner 1
13 Bard Mfg. Co.W24A1 User manual Air Conditioner 3
14 Bard Mfg. Co.W42L2 User manual Air Conditioner 0
15 Bard Mfg. Co.W18A1 User manual Air Conditioner 0
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21