Peavey ICA Series user manual

User manual for the device Peavey ICA Series

Device: Peavey ICA Series
Category: Music Mixer
Manufacturer: Peavey
Size: 5.71 MB
Added : 6/19/2014
Number of pages: 64
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Peavey ICA Series. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Peavey ICA Series.

For your convenience

If looking through the Peavey ICA Series user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Peavey ICA Series on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Peavey ICA Series to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Peavey ICA Series User manual - Online PDF
Advertisement
« Page 1 of 64 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Peavey ICA Series but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Peavey ICA Series. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


ICA SERIES
INDUSTRIAL CONTRACTOR AMPLIFIERS
OPERATING GUIDE

Summary of the content on the page No. 2

Intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. Intended to alert the user of the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product. CAUTION: Risk of electrical shock — DO NOT OPEN! CAUTION: To reduce the risk of electric shock, do not remove cover. No user serviceable parts inside.

Summary of the content on the page No. 3

TABLE OF CONTENTS Page INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 UNPACKING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 INSTALLATION AND MOUNTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 BASIC SETUP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 FRONT PAN

Summary of the content on the page No. 4

ENGLISH INTRODUCTION ™ Congratulations on your purchase of an Architectural Acoustics ICA (Industrial Contractor Amplifier) from Peavey Electronics. Please read this manual carefully, especially the IMPORTANT SAFETY INSTRUCTIONS on page 18. It contains information vital to safe operation of the power amplifier. Also, please fill out and return the enclosed product registration card. ICA Series amplifiers represent new levels of value and flexibility never before offered to the contracting market

Summary of the content on the page No. 5

FRONT PANEL FEATURES RCHITECTURAL TM POWER 600 A TM INDUSTRIAL SIGNAL CLIP LFC COUSTICS TM CONTRACTOR PROTECT POWER B AMPLIFIER STANDBY OFF ON by 4 5 6 7 3 2 1 1. RACK MOUNTING EARS These mounting holes are provided on each front mounting ear. 2. 3-POSITION AC POWER SWITCH A 3-position switch is on the front panel. Sequential remote turn-on capability is a standard feature. With the switch pushed towards the outside position, the amplifier is ON. The middle position is OFF, and the inside positi

Summary of the content on the page No. 6

BACK PANEL FEATURES 9 10 11 12 13 8 8. INPUT SECTION ™ The ICA Series comes standard with plugable input connectors and individual channel rotary attenuators. Connections at the input connector permit the audio signal ground to be connected or lifted from the chassis ground. 9. OUTPUT BARRIER STRIP A barrier strip is provided for connection of loudspeakers with bare wire or spade lug connectors. This barrier strip can accommodate up to two 10-gauge wires per terminal. 10. IEC POWER CONNECTOR A

Summary of the content on the page No. 7

connecting the ENABLE OUT to the ENABLE IN of the next amplifier. A mating connector is shipped with the amplifier. 13. FAN GRILL A continuously variable-speed DC fan supplies cool air into the amplifier. Do not block this intake! The fan operates only when the amplifier heat sinks require cooling. OPERATION AC MAINS CIRCUIT SIZE REQUIREMENTS ™ Power requirements for ICA amplifiers are rated at “idle”, 1/8 power (“typical” music conditions), 1/3 power, and maximum rated power. The maximum power

Summary of the content on the page No. 8

SIGNAL MODE CONFIGURATION ™ ICA Series amplifiers are configured for Stereo (2-channel), Bridged Mode, or Parallel Mode operation at the input connector. To send the same signal to both channels (Parallel Mode), connect the input signal to CHANNEL A via the input connector. Run jumpers from the positive and negative terminals of the CHANNEL A input connector to the respective terminals of CHANNEL B. Both channels then share the CHANNEL A input signal but will operate independently. Speakers are

Summary of the content on the page No. 9

BRIDGED MODE DIAGRAM RCHITECTURAL TM COUSTICS 600 TM INDUSTRIAL CONTRACTOR AMPLIFIER 120 VAC by 60 Hz OUTPUT B OUTPUT A 700 WATTS CLASS 2 WIRING CAUTION OUTPUT POWER @ 4 OHMS IS 300 WATTS/CH -6 -6 -10 -3 -10 -3 WARNING: TO REDUCE THE RISK OF FIRE OR -15 -15 ENABLE IN ENABLE OUT ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT -1 -1 TO RAIN OR MOISTURE. 24V DC+ COMMON -30 -30 INPUT B INPUT A AVIS: RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIR. -80 0 -80 0 LEVEL B LEVEL A MOUNT IN RACK ONLY (dB) (dB) INSTALL

Summary of the content on the page No. 10

FADE-IN PROTECTION This feature operates every time the amplifier is turned on, or after a protect condition. During turn on, the amplifier goes into protect mode and leaves the speaker load disconnected until the amplifier determines that the operating status is normal. The Fade-In circuit attenuates the signal during the initial turn on or protect operation. After relay release, channel gain gradually increases to the attenuator setting to avoid unnecessary stress on the loudspeakers. THERMAL

Summary of the content on the page No. 11

WIRE GAUGE CHART Stranded Power Power Power Cable Wire Loss Loss Loss Length Gauge Into Into Into (Feet) (AWG) 8 ohms 4 ohms 2 ohms ______________________________________________________ 5' 18 AWG .79% 1.58% 3.16% 16 .5 1.0 2.0 14 .31 .62 1.24 12 .20 .40 .80 10 .125 .25 .50 10' 18 AWG 1.58% 3.16% 6.32% 16 1.0 2.0 4.00 14 .62 1.25 2.50 12 .40 .80 1.6 10 .25 .50 1.0 40' 18 AWG 8.0% 12.6% 25.2% 16 4.0 8.0 16.0 14 2.5 5.0 10.0 12 1.60 3.2 6.4 10 1.0 2.0 4.0 8 .625 1.25 2.50 80' 16 AWG 8.0% 16.0%

Summary of the content on the page No. 12

™ ICA 600 SPECIFICATIONS Rated Power (2 X 4 ohms): Slew Rate: Cooling: 300 watts @ 20 Hz - 20 kHz, both 30 V/µs 80 mm DC fan, off until heatsinks channels driven at < 0.1% THD reach 45° C, then variable speed Damping Factor (8 ohms): Rated Power (2 x 8 ohms): >450:1 @ 20 Hz - 1 kHz Controls: 200 watts @ 20 Hz - 20 kHz at 2 rear panel attenuators, sequential < 0.05% THD Input CMRR: turn-on / off >-65 dB @ 1 kHz Rated Power (1 x 4 ohms): Indicator LEDs: 360 watts @ 1 kHz at < 0.015% THD Voltage G

Summary of the content on the page No. 13

™ ICA 1200 SPECIFICATIONS Rated Power (2 X 4 ohms): Slew Rate: Cooling 600 watts @ 20 Hz - 20 kHz, both 30 V/µs 120 mm DC fan, off until heatsinks channels driven at < 0.1% THD reach 45° C, then variable speed Damping Factor (8 ohms): Rated Power (2 X 8 ohms): >350:1 @ 20 Hz - 1 kHz Controls: 400 watts @ 20 Hz - 20 kHz, both 2 rear panel attenuators, sequential Input CMRR: channels driven at < 0.05% THD turn-on / off >-65 dB @ 1 kHz Rated Power (1 X 4 ohms): Indicator LEDs: Voltage Gain: 700 w

Summary of the content on the page No. 14

™ ICA 2400 SPECIFICATIONS Rated Power (2 x 4 ohms): SMPTE IMD: Thermal Emissions (BTU/hr.): 1200 watts @ 20 Hz - 20 kHz both <0.1% 60 Hz and 7 kHz, 800 W @ 940 @ 1/8 power 4 ohms, channels driven at < 0.1% THD 8 ohms 615 @ 1/8 power 8 ohms, 1830 @ 1/3 power 4 ohms, Rated Power (2 x 8 ohms): Slew Rate: 1335 @ 1/3 power @ 8 ohms 800 watts @ 20 Hz – 20 kHz both 35 V/us channels driven at < 0.08% THD Cooling: Damping Factor (8 ohms): 120 mm DC fan, off until heatsinks Rated Power (1 x 4 ohms): >250

Summary of the content on the page No. 15

™ ICA 400V SPECIFICATIONS Rated Power (two channels): Input CMRR: Cooling: 200 watts @ 20 Hz - 20 kHz both > -65 dB @ 1 kHz 80 mm DC fan, off until heatsinks o channels driven at <0.1% THD reach 45 C, then variable speed Voltage Gain: Rated Power (one channel): x40 (32 dB) Controls: 215 watts @ 1 kHz at <0.0075% 2 rear panel attenuators, sequential Input Sensitivity: THD turn-on / off ICA 400V-70: Minimum Load Impedance: 1.77 volts for rated output Indicator LEDs: ICA 400V-70: 25 ohms ICA 40

Summary of the content on the page No. 16

™ ICA 800V SPECIFICATIONS Rated Power (two channels): Damping Factor: Thermal Emissions (BTU/hr.): 400 watts @ 20 Hz - 20 kHz both >400:1 @ 20 Hz - 400 Hz 550 @ 1/8 power, channels driven at < 0.1% THD 835 @ 1/3 power Input CMRR: Rated Power (one channel): >-65 dB @ 1 kHz Cooling: 415 watts @ 1 kHz at < 0.01% THD 120 mm DC fan, off until heatsinks Voltage Gain: o reach 45 C, then variable speed Minimum Load Impedance: x40 (32 dB) ICA 800V-70: 12.5 ohms Controls: Input Sensitivity: ICA 800V-1

Summary of the content on the page No. 17

™ ICA 2400V SPECIFICATIONS Rated Power (2 x 4 ohms): Slew Rate: Cooling: 1200 watts @ 20 Hz - 20 kHz both 35 V/us 120 mm DC fan, off until heatsinks channels driven at < 0.1% THD ° reach 45 C, then variable speed Damping Factor (8 ohms): Rated Power (2 x 8 ohms): >250:1 @ 20 Hz – 1 kHz Controls: 800 watts @ 20 Hz – 20 kHz both 2 rear panel attenuators, sequential channels driven at < 0.08% THD Input CMRR: turn-on / off > 65 dB @ 1 kHz Rated Power (1 x 4 ohms): Indicator LEDs: 1325 watts @ 1 kHz

Summary of the content on the page No. 18

ESPAÑOL INTRODUCCIÓN ™ Felicidades en su compra de un amplificador de Acústica Arquitectónica ICA (Amplificador de Contratistas Acústicos por sus siglas en Inglés) de Peavey Electronics. Por favor lea este manual con atención, especialmente la seccione de SEGURIDAD en la página 18. Esta contiene información vital para la operación segura del amplificador. Por favor tómese el tiempo de llenar y mandar su tarjeta de registro del producto. La serie de amplificadores ICA presenta nuevos niveles de v

Summary of the content on the page No. 19

4. Lleve a cabo las conexiones de poder, cubriendo las necesidades del amplificador. Vea las secciones CONECTOR IEC y Requisitos de los circuitos de CA para más información. 5. Gire el interruptor de poder (AC POWER) de tres posiciones a la posición ON y suba los atenuadores de ganancia (LEVEL) en el panel trasero a los niveles deseados. CARACTERÍSTICAS DEL PANEL FRONTAL RCHITECTURAL TM POWER 600 A TM INDUSTRIAL SIGNAL CLIP LFC COUSTICS TM CONTRACTOR PROTECT POWER AMPLIFIER B STANDBY OFF ON by

Summary of the content on the page No. 20

CARACTERÍSTICAS DEL PANEL TRASERO 10 11 9 RCHITECTURAL TM 600 COUSTICS TM INDUSTRIAL CONTRACTOR AMPLIFIER 220/240~ VAC by 50/60 Hz OUTPUT B OUTPUT A 700 WATTS CLASS 2 WIRING CAUTION OUTPUT POWER @ 4 OHMS IS 300 WATTS/CH -6 -6 -10 -3 -10 -3 WARNING: TO REDUCE THE RISK OF FIRE OR -15 -15 ENABLE IN ENABLE OUT ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT -1 -1 24V DC+ COMMON TO RAIN OR MOISTURE. -30 -30 INPUT B INPUT A AVIS: RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIR. -80 0 -80 0 LEVEL B LEVEL A MOUNT I


Alternative user manuals
# User manual Category Download
1 Peavey 600 Mixer User manual Music Mixer 56
2 Peavey 701R User manual Music Mixer 97
3 Peavey 900 Mixer User manual Music Mixer 6
4 Peavey 1200 Stereo User manual Music Mixer 23
5 Peavey AMD 1220 User manual Music Mixer 4
6 Peavey 601R User manual Music Mixer 11
7 Peavey 2443/3243 User manual Music Mixer 8
8 Peavey 3D Mix Pro User manual Music Mixer 10
9 Peavey 502 User manual Music Mixer 2
10 Peavey AMR 42 User manual Music Mixer 3
11 Peavey AMA 1200 User manual Music Mixer 1
12 Peavey Automix 4 User manual Music Mixer 2
13 Peavey AMR 64 User manual Music Mixer 10
14 Peavey DEP 800 User manual Music Mixer 1
15 Peavey DSM 752 User manual Music Mixer 11
16 Sony 2-190-733-11 (1) User manual Music Mixer 1
17 Sony DMBK-R103 User manual Music Mixer 6
18 Sony DMBK-R106 User manual Music Mixer 1
19 Sony RS-232C User manual Music Mixer 1
20 Sony DMBK-R105 User manual Music Mixer 1