Amcor CPLM 12KE-B-410 user manual

User manual for the device Amcor CPLM 12KE-B-410

Device: Amcor CPLM 12KE-B-410
Category: Air Conditioner
Manufacturer: Amcor
Size: 0.74 MB
Added : 12/21/2013
Number of pages: 15
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Amcor CPLM 12KE-B-410. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Amcor CPLM 12KE-B-410.

For your convenience

If looking through the Amcor CPLM 12KE-B-410 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Amcor CPLM 12KE-B-410 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Amcor CPLM 12KE-B-410 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Amcor CPLM 12KE-B-410 User manual - Online PDF
Advertisement
« Page 1 of 15 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Amcor CPLM 12KE-B-410 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Amcor CPLM 12KE-B-410. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

CPLM 9KE-B-410 12KE-B-410 15KE-B-410



GB Portable air conditioner
PORTABLE AIR CONDITIONER

Summary of the content on the page No. 2

GB THANK YOU Thank you for choosing this innovative Amcor air conditioner. We suggest that you keep this manual in a safe place for future reference. It describes the many benefits and advanced features this unique product has to offer. Before you use your new air conditioner you should carefully read these instructions to maximise this product’s performance. For over 50 years Amcor has specialised in complete indoor environmental control, manufacturing and marketing; dehumidifiers, portab

Summary of the content on the page No. 3

GB WARNING • Never operate this appliance if it has a damaged cord or plug. Do not lead the cord over sharp edges. • A damaged supply cord should be replaced by the manufacturer, its service agent or a qualified person in order to avoid a hazard. • Any service other than regular cleaning or filter replacement should be performed by an authorized service representative. Failure to do so could result in a loss of warranty. Do not use your air conditioner under the following conditions: If

Summary of the content on the page No. 4

GB PARTS 1 5 2 6 3 3 7 8 9 10 4 1. Air outlet 5. Grill housing 2. Control panel 6. Upper air inlet 3. Carrying handle 7. Exhaust air outlet 4. Caster wheels 8. Lower air inlet 9. Cable storage 10. Drainage point with water stopper Water container Exhaust hose Active carbon filter Remote control with LCD Slide bar connector Telescopic slide bar 4

Summary of the content on the page No. 5

GB CONTROL PANEL Clock/ Cooling Sleep Timer mode Fan Mode Timer Increase Sleep mode Decrease Swing Sensor ON / OFF remote control Temperature Fan Timer settings 5

Summary of the content on the page No. 6

GB INSTALLATION WARNING! Before using the air conditioner it should be left in an upright position for at least 2 hours. This unit can easily be moved from one room to another. In doing so keep this in mind: – Ensure that the unit is positioned upright, on a level surface and 50 cm away from any obstacles. – To place the loose filters in the filter holder. • Take the filter holder out of the air conditioner. • Open the filter holder and place the active carbon filter (black) in the filter

Summary of the content on the page No. 7

GB OPERATION ON/OFF Press to switch the unit on or to switch off. A buzzer will beep, and the LCD will display 12:00 o’clock as default. Setting the clock Press the -button for 3 seconds to set the clock. The 2 left digits of the 4 digits on the LCD-display will flash. Press or to adjust the hour. Press momentarily, the 2 right digits of the 4 digits will flash. Press or to adjust the minutes of the clock. Press the -button for 3 seconds again to activate the clock. Setting the tempe

Summary of the content on the page No. 8

GB Programming the timer for ON - when the unit is OFF. • Perform the standard steps as described above. The linear time scale will be on between the ON programmed times until 24:00. The flashing bar on the time scale indicates the real time and moves a segment ahead every 30 minutes until it reaches the ON timer time, then the black segments in the linear time scale will disappear. Programming the timer for OFF - when the unit is RUNNING. • Perform the standard steps as described above.

Summary of the content on the page No. 9

GB Air flow On the moment the air conditioner is connected to the mains, the louvres open and close and stay closed. • When the ON-button is pressed, the louvres open to maximum and return to an angle of 75° above the upper plane of the louvres housing. • Press the -button, the louvres will swing continuously up and down between 30° and 80° above the upper plane of the louvres housing. • By pressing the -button again the movement will stop and the louvres remain in that position. The dir

Summary of the content on the page No. 10

GB REMOTE CONTROL The unit responds to all signals that are sent by the remote control. There will be a beep sound from the unit after receiving the signal. The operation of the unit by remote control, is almost identical to the operation by the control panel. The only exception is the clock function. Instead of the -button for setting the actual time and for programming the timer, there are 3 push buttons on the remote control as follows: • - for setting the actual time. • TIMER ON -

Summary of the content on the page No. 11

GB AIR FILTERS This air conditioner is equipped with two filter sets: 1. A multi layer filter in the upper air inlet, to clean the circulated room air, which includes a. A screen filter, to remove dust particles. b. An active carbon filter, to remove odours. 2. A screen filter in the lower air inlet, to remove dust particles. NOTE! The active carbon filter is delivered in a plastic packaging. Don’t forget to install it. Cleaning the air filters a. The screen filters in the upper and lowe

Summary of the content on the page No. 12

GB EMPTYING THE INTERNAL WATER CONTAINER Under high humidity conditions it may be necessary to empty the internal water container. When the internal water container is full the backlight on the LCD-display flashes. The unit will switch off automatically. To empty the water container do the following: • Switch off the unit and remove the plug from the wall socket. Do not move the unit. Doing this can result in water leakage, damaging your floor or carpet. • Place the water container on the

Summary of the content on the page No. 13

GB STORAGE • Empty the internal water container. • Clean the screen filter. • Remove the active carbon filter before end of season storage and install new filters at the beginning of the new season. • The old filters can be disposed of in the ‘Non-biological rubbish container’. Replacement filter packages are available from Amcor. • Put the unit in Fan Only mode for a few hours to ensure that the inside becomes completely dry. • Store the cable as shown. Protect the unit against du

Summary of the content on the page No. 14

GB TECHNICAL DATA Model CPLM CPLM CPLM 9KE-B-410 12KE-B-410 15KE-B-410 BTU/h 7500 9900 11300 Cooling capacity measured conform EN 14511 kW 2.2 2.9 3.3 Power consumption kW 0.77 0.99 1.36 Current A 3.4 4.3 5.9 Mains V / Hz / Ph 220 – 240 / 50 / 1 Fan speeds 3 Thermostatic range °C 18 – 32 Protection class IP 21 Refrigerant type R410A Refrigerant load g 420 500 630 Dimensions (w x h x d) mm 500 x 840 x 415 Net weight kg 33.1 34.3 39.3 CPLM 9KE-B-410 series can be connected only to a supply with

Summary of the content on the page No. 15

Hong Kong Amcor Ltd Suite 2007, Tower 6, The Gateway, Harbour City, 9 Canton Road, Tsim Sha Tsui, Kowloon, Hong Kong Tel: +852 2997 6865 Fax: +852 2997 6091 Email: amcorhk@amcorgroup.com United Kingdom Amcor Ltd 9 Ryan Drive, West Cross Centre, Great West Road, Brentford, Middlesex, TW8 9ER, United Kingdom Tel: +44 20 8560 4141 Fax: +44 20 8232 8814 Email: amcoruk@amcorgroup.com USA Amcor Inc. 685A Gotham Parkway, Carlstadt, New Yersey 07072, United States of America Tel: +1 201 460 8100 Fax: +1


Alternative user manuals
# User manual Category Download
1 Amcor 000EH User manual Air Conditioner 108
2 Amcor 7KE-410 User manual Air Conditioner 54
3 Amcor A12000EH User manual Air Conditioner 136
4 Amcor 12KE-410 User manual Air Conditioner 171
5 Amcor 12000E User manual Air Conditioner 212
6 Amcor 9KE-410 User manual Air Conditioner 12
7 Amcor 000E/EH User manual Air Conditioner 6
8 Amcor AHW 164 User manual Air Conditioner 8
9 Amcor 15KE-410 User manual Air Conditioner 39
10 Amcor AMC 10KM-410 User manual Air Conditioner 128
11 Amcor ALD-12 User manual Air Conditioner 10
12 Amcor aire AOS180HR User manual Air Conditioner 4
13 Amcor Inc.CF14000E User manual Air Conditioner 84
14 Amcor ALD-1 2 User manual Air Conditioner 5
15 Amcor ALW-12 User manual Air Conditioner 9
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21