Agilent Technologies 66001A user manual

User manual for the device Agilent Technologies 66001A

Device: Agilent Technologies 66001A
Category: Mouse
Manufacturer: Agilent Technologies
Size: 0.59 MB
Added : 4/10/2013
Number of pages: 55
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Agilent Technologies 66001A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Agilent Technologies 66001A.

For your convenience

If looking through the Agilent Technologies 66001A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Agilent Technologies 66001A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Agilent Technologies 66001A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Agilent Technologies 66001A User manual - Online PDF
Advertisement
« Page 1 of 55 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Agilent Technologies 66001A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Agilent Technologies 66001A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1








USER’S GUIDE
Agilent Technologies
Series 661xxA
MPS POWER MODULES
& Model 66001A MPS KEYBOARD




























!A

Agilent Part No. 5959-3386 Printed in Malaysia
Microfiche Part No. 5959-3387 September 2004

Summary of the content on the page No. 2

CERTIFICATION Agilent Technologies certifies that this product met its published specifications at time of shipment from the factory. Agilent Technologies further certifies that its calibration measurements are traceable to the United States National Bureau of Standards, to the extent allowed by the Bureau's calibration facility, and to the calibration facilities of other International Standards Organization members. WARRANTY This Agilent Technologies hardware product is warranted ag

Summary of the content on the page No. 3

SAFETY SUMMARY The following general safety precautions must be observed during all phases of operation of this power module. Failure to comply with these precautions or with specific warnings elsewhere in this guide violates safety standards of design, manufacture, and intended use of the power module. Agilent Technologies assumes no liability for the customer's failure to comply with these requirements. GENERAL When installed in a properly wired mainframe, this product is a Safety

Summary of the content on the page No. 4

SAFETY SYMBOL DEFINITIONS Symbol Description Symbol Description Direct current Terminal for Line conductor on permanently installed equipment Alternating current Caution, risk of electric shock Both direct and alternating current Caution, hot surface Three-phase alternating current Caution (refer to accompanying documents) Earth (ground) terminal In position of a bi-stable push control Protective earth (ground) terminal Out position of a bi-stable push control Fram

Summary of the content on the page No. 5

DECLARATION OF CONFORMITY According to ISO/IEC Guide 22 and CEN/CENELEC EN 45014 Manufacturer’s Name and Address Responsible Party Alternate Manufacturing Site Agilent Technologies, Inc. Agilent Technologies (Malaysia) Sdn. Bhd 550 Clark Drive, Suite 101 Malaysia Manufacturing Budd Lake, New Jersey 07828 Bayan Lepas Free Industrial Zone, PH III USA 11900 Penang, Malaysia Declares under sole responsibility that the product as originally delivered Product Names a) Modu

Summary of the content on the page No. 6

Summary of the content on the page No. 7

Table of Contents 1. General Information Introduction ..................................................................................................................................................9 Safety Considerations...................................................................................................................................9 Instrument Identification .............................................................................................................

Summary of the content on the page No. 8

Table of Contents (continued) Module Output Connector.......................................................................................................................29 Error Messages...................................................................................................................................29-30 4. Basic Power Module Commands Introduction ...................................................................................................................

Summary of the content on the page No. 9

1 General Information Introduction This guide describes how to install, check out, operate, and calibrate the Agilent Series 661xxA power modules used in the Agilent 66000 Modular Power System. Programming the power module from the optional Agilent 66001A Keyboard is described in Appendix B of this guide. Programming the power module over the GPIB bus is covered in the module Programming Guide (see "Related Documents", below). Setting the GPIB address is described in the mainframe Installatio

Summary of the content on the page No. 10

Accessories Agilent No. Description 34551A Rack mount for Agilent 66001A MPS keyboard Description The Agilent 66lxxA Series Power Modules are used in the Agilent 66000 Modular Power System (MPS) mainframe to provide a range of dc output voltages and currents. The modules are installed or removed from the front of the mainframe without the need for disconnecting any wires. Modules may be connected in series or parallel to provide increased output voltages or currents. The modules can be eq

Summary of the content on the page No. 11

When the power module is operated beyond either rated output, the performance specifications are not guaranteed, although typical performance may be good. Operation in quadrant 2 is limited to about 10% of the maximum rated positive output current. This allows the power module to sink current for more rapid downprogramming in the CV mode. Specifications and Supplemental Characteristics Table 1-1 lists the specifications of the power modules. Specifications are warranted over the specified tem

Summary of the content on the page No. 12

Table 1-1. Performance Specifications (continued) Agilent Model Parameter 66101A 66102A 66103A 66104A 66105A 66106A Line Regulation (change in output voltage or current for any line change within ratings) Voltage: 0.5 mV 0.5 mV 1 mV 2 mV 3 mV 5 mV Current: 0.75 mA 0.5. mA 0.3 mA 0.1 mA 50 μA 30 μA Transient Response Time (for output voltage to recover to within 100 mV of < 1 ms its previous level following a step change in load current that is up to 10% of the power module rated output cu

Summary of the content on the page No. 13

Table 1-2. Supplemental Characteristics (continued) Agilent Model Parameter 66101A 66102A 66103A 66104A 66105A 66106A Temperature Coefficients (change in output per °C after a 30-minute warmup) Output Voltage: 30 ppm + 0.1 mV 0.2 mV 0.3 mV 0.6 mV 1.1 mV 1.8 mV Output Current: 30 ppm + 0.2 mA 0.1 mA 0.05 mA 0.03 mA 0.01 mA 0.006 mA Voltage Readback: 20 ppm + 0.1 mV 0.2 mV 0.2 mV 0.7 mV 0.7 mV 1.1 mV 20 ppm + 0.2 mA 0.1 mA 0.05 mA 0.02 mA 0.02 mA 0.02 mA ± Current Readback: OV Protection: 1 mV

Summary of the content on the page No. 14

Table 1-2. Supplemental Characteristics (continued) Agilent Model Parameter 66101A 66102A 66103A 66104A 66105A 66106A Trigger Response Time (average time for the output voltage or current to begin to change upon receipt of an external trigger) With GPIB activity: 5 ms Without GPIB activity: 3 ms Trigger Maximum Frequency (for repetitive external triggering, the maximum frequency for which the Trigger Response Time is valid) With GPIB activity: 75 Hz Without GPIB activity: 85 Hz Dwel

Summary of the content on the page No. 15

Table 1-2. Supplemental Characteristics (continued) Parameter Agilent Model Number and Parameter Value Output Characteristic Curve: Table 1-3. Replaceable Parts List Description Agilent Part No. Cable assembly, mainframe GPIB 0.5 meters (1.6 ft) 10833D 1 meter (3.3 ft) 10833A 2 meters (6.6 ft) 10833B 4 meters (13.2 ft) 10833C Cable assembly, mainframe serial link 5080-2148 Fuse, ac-line, 6 A 2110-0056 Output connector, standard 5060-3386 Output connect

Summary of the content on the page No. 16

Summary of the content on the page No. 17

2 Installation Inspection Damage When you receive your power module, inspect it for any obvious damage that may have occurred during shipment. If there is damage, notify the shipping carrier and the nearest Agilent Sales and Support Office immediately. Warranty information is printed in the front of this guide. Items Supplied In addition to this manual, check that the following items are included with each power module (see Table 1-3 for part numbers): • One output connector • One Series 66lxx

Summary of the content on the page No. 18

Figure 2-1. Power Module Line Fuse and Switches Figure 2-2. Power Module Configuration Switch Table 2-1. Settings for Power Module Configuration Switch Required Switch Setting Desired Function 1 2 3 4 5 6 7* 8* RI disabled 0 0 1 1 RI unlatched (live) 0 1 1 1 RI latching † 1 1 1 1 Display disabled 0 1 1 Display enabled † I 1 1 Inhibit calibration 0 0 1 1 Factory calibration 0 1 1 1 Normal calibration † 1 1 1 1 Power on state is *RCL 0 011 Power on state is *RST† 111 †= factory default setting

Summary of the content on the page No. 19

Remote Inhibit (RI) Function Switches This function allows the power module outputs to be shut down from a signal (low-true TTL level) applied to the mainframe INH input. The INH input is internally connected to the mainframe remote inhibit (RI) line. This line is normally high and is distributed to all power modules in the mainframe. An external switch closure that shorts the mainframe INH input is detected by the power module as an RI signal. Note See "Chapter 3 - Connections" in the mainfr

Summary of the content on the page No. 20

Installing The Module In The Mainframe Figure 2-3. Power Module Installation Note A fully loaded mainframe can weigh over 36 kg (80 lbs). Install the mainframe into the rack (see the "Mainframe Users Guide") before installing the modules into the mainframe. 1. Turn off the mainframe power switch. 2. Make certain the pull tab extends from the module (see Figure 2-3). 3. Slide the module into the mainframe slot. You may use any available slot. 4. Push the module into the backplane connector unt


Alternative user manuals
# User manual Category Download
1 3M EM 550GPL User manual Mouse 3
2 3M EM 550GPS User manual Mouse 1
3 Sony PEGA-KB100 User manual Mouse 3
4 Sony 263 User manual Mouse 0
5 Sony User manual Mouse 1
6 Sony PCGA-UMS3 User manual Mouse 2
7 Sony SMU-CL2 User manual Mouse 1
8 Sony PEGA-KB20 User manual Mouse 0
9 Sony SMU-CM2 User manual Mouse 1
10 Sony Wireless LaserVGPWMS10W User manual Mouse 0
11 Acer LZ20400161 User manual Mouse 0
12 Sony BLUETOOTH VGP-BMS55 User manual Mouse 129
13 A4 Tech. Wireless 1-Wheel User manual Mouse 5
14 A4 Tech. NB-30 User manual Mouse 8
15 A4 Tech. X-708 User manual Mouse 9