Summary of the content on the page No. 1
ACCULINK
316x DATA SERVICE UNIT/
CHANNEL SERVICE UNIT
(INCLUDES TERMINAL USER
INTERFACE)
OPERATOR’S GUIDE
Document No. 3160-A2-GB22-10
December 1996
Summary of the content on the page No. 2
ACCULINK 316x DSU/CSU ACCULINK 316x Data Service Unit/Channel Service Unit (includes Terminal User Interface) Operator’s Guide 3160-A2-GB22-10 2nd Edition (December 1996) Changes and enhancements to the product and to the information herein will be documented and issued as a new release to this manual. Standalone FCC Registration number: See label on unit Ringer Equivalence number (REN): See label on unit Canadian Certification number: See label on unit Canadian DOC Load number: See label on uni
Summary of the content on the page No. 3
Safety Instructions Important Safety Instructions 1. Read and follow all warning notices and instructions marked on the product or included in the manual. 2. This product is intended to be used with a three-wire grounding type plug - a plug which has a grounding pin. This is a safety feature. Equipment grounding is vital to ensure safe operation. Do not defeat the purpose of the grounding type plug by modifying the plug or using an adaptor. Prior to installation, use an outlet tester or a voltme
Summary of the content on the page No. 4
ACCULINK 316x DSU/CSU Notices
Summary of the content on the page No. 5
Government Requirements Government Requirements and Equipment Return Certain governments require that instructions pertaining to DSU/CSU and modem connection to the telephone network be included in the installation and operation manual. Specific instructions are listed in the following sections. United States NOTICE TO USERS OF THE UNITED STATES TELEPHONE NETWORK 1. This equipment complies with Part 68 of the FCC rules. On the equipment is a label that contains, among other information, the FCC
Summary of the content on the page No. 6
ACCULINK 316x DSU/CSU 5. The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make the necessary modifications in order to maintain uninterrupted service. 6. If you experience trouble with this equipment, please contact your sales or service representative (as appropriate) for repair or warranty information. If the prod
Summary of the content on the page No. 7
Government Requirements CAUTION Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate. The load number is labeled on the equipment. The load number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device to prevent overloading. The termination on a loop may consist of any combination of devices subject only
Summary of the content on the page No. 8
Table of Contents Preface Objectives and Reader Assumptions . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Related Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Reference Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii 1. Introduction Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Features . . . . . . . . . . . . . . . . . . . . . . .
Summary of the content on the page No. 9
ACCULINK 316x DSU/CSU 3. Operation Operating the Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 Configuring the DSU/CSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-16 Configuring DS0 Channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-34 Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-49 Selecting the Shared Communication Port . . . . . . . . .
Summary of the content on the page No. 10
Table of Contents List of Figures Figure Page 1-1 3160 DSU/CSU Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 1-2 3164 DSU/CSU Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 1-3 3160 DSU/CSU Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 1-4 3164 DSU/CSU Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Summary of the content on the page No. 11
ACCULINK 316x DSU/CSU Figure Page 3-21 Edit User Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-26 3-22 Communication Port Options Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-28 3-23 Trap Options Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-33 3-24 Example Channel Allocation . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Summary of the content on the page No. 12
Table of Contents List of Tables Table Page 1-1 Models 3160/3614 DSU/CSUs Rear Panel Connectors . . . . . . . . . . . . . . . . . . . . . . 1-7 1-2 Auxiliary Backplane Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8 3-1 System LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7 3-2 NETWORK Interface LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Summary of the content on the page No. 13
ACCULINK 316x DSU/CSU Table Page D-1 T1 Network Interface Connector (J4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-2 D-2 T1 Network Interface Connector (DA15P) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-3 D-3 (DSX-1) DTE Interface Connector (J3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-4 D-4 Integral Modem Service Port Connector (J5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-5 D-5 Extended M
Summary of the content on the page No. 14
Preface Objectives and Reader Reference Documents Assumptions • AT&T Technical Reference 54016 This operator’s guide contains installation and • AT&T Technical Reference 62411 operation information for the ACCULINK 316x Data • ANSI T1.403-1989 Service Unit (DSU)/Channel Service Unit (CSU). • DOC Certification Standard CS-03 • CSA-22.2 No. 950-M89 Related Documents • CSA 108-M1983 Contact your sales representative for additional • FCC Part 15 product documentation. • FCC Part 68 3000-A2-GA31 COM
Summary of the content on the page No. 15
Introduction 1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Integral Modem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 User Inter
Summary of the content on the page No. 16
ACCULINK 316x DSU/CSU • Independently selectable DTE interfaces (V.35, User Interface EIA-530A, V.11, and/or RS449/422). There are three ways of accessing the user interface: • Flexible timing source, available from the • Front panel – provides an LCD and a keypad T1 network interface, the DSX-1 T1 interface, at which enable you to display information about and least one of the synchronous DCE data ports, an interact with the DSU/CSU. A menu tree is internal clock, or an external clock. availab
Summary of the content on the page No. 17
Introduction Procedures throughout this manual are described Front Panel Emulation specifically for a front panel user. Look for the subhead The 3160/3164 DSU/CSU offers the same functionality Differences Using the Async Terminal within each through Front Panel Emulation software as that provided procedure section for the user interface information on the by the DSU/CSU front panel. The DSU/CSU can either be Async Terminal feature. locally attached to a 286 or higher PC, or remotely through a lo
Summary of the content on the page No. 18
ACCULINK 316x DSU/CSU SNMP is an industry-standard network management ACCULINK 316x DSU/CSU system that is used to monitor network performance and status, and to report alarms (i.e., traps). To function, Physical Description SNMP requires a manager consisting of a software The ACCULINK 316x DSU/CSU series of products program housed within a workstation; an agent consisting consists of a standalone 2-port Model 3160 DSU/CSU, a of a software program housed within a device (e.g., standalone 4-port
Summary of the content on the page No. 19
Introduction LCD KEYPAD ACCULINK F1 F2 F3 NET NET EQPT MON MON In In In OK FAIL TEST SIG OOF ALRM EER SIG OOF ALRM PDV BPV Out Out Out NETWORK DTR TXD RXD CTS RTS 496-14539-03 TEST JACKS LEDs Figure 1-1. 3160 DSU/CSU Front Panel LCD ACCULINK F1 F2 F3 NET NET EQPT MON MON In In In OK FAIL TEST SIG OOF ALRM EER SIG OOF ALRM PDV BPV 3164 Out Out Out NETWORK DTR TXD RXD CTS RTS 496-14566-01 Figure 1-2. 3164 DSU/CSU Front Panel 3160-A2-GB22-10 December 1996 1-5
Summary of the content on the page No. 20
ACCULINK 316x DSU/CSU Figure 1-3. 3160 DSU/CSU Rear Panel Figure 1-4. 3164 DSU/CSU Rear Panel 1-6 December 1996 3160-A2-GB22-10