Mitsubishi Electronics MITSUBISHI MAM MAM-AM6 user manual

User manual for the device Mitsubishi Electronics MITSUBISHI MAM MAM-AM6

Device: Mitsubishi Electronics MITSUBISHI MAM MAM-AM6
Category: Modem
Manufacturer: Mitsubishi Electronics
Size: 0.93 MB
Added : 10/27/2013
Number of pages: 48
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Mitsubishi Electronics MITSUBISHI MAM MAM-AM6. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Mitsubishi Electronics MITSUBISHI MAM MAM-AM6.

For your convenience

If looking through the Mitsubishi Electronics MITSUBISHI MAM MAM-AM6 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Mitsubishi Electronics MITSUBISHI MAM MAM-AM6 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Mitsubishi Electronics MITSUBISHI MAM MAM-AM6 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Mitsubishi Electronics MITSUBISHI MAM MAM-AM6 User manual - Online PDF
Advertisement
« Page 1 of 48 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Mitsubishi Electronics MITSUBISHI MAM MAM-AM6 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Mitsubishi Electronics MITSUBISHI MAM MAM-AM6. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

MITSUBISHI ELECTRIC
MitsubishiMAMseries
Alarm Modems
Instruction Manual
Draft
MAM-GM6, GM20, GM24
MAM-AM6, AM20, AM24
Art.-No.: 165590
26 10 2005
INDUSTRIAL AUTOMATION
MITSUBISHI ELECTRIC
Version A

Summary of the content on the page No. 2

Summary of the content on the page No. 3

About this Manual The texts, illustrations, diagrams and examples in this manual are only intended as aids to help explain the functioning, operation, use and programming of the Mitsubishi Alarm Modems. If you have any questions regarding the installation and operation of the software described in this manual, please do not hesitate to contact your sales office or one of your Mitsubishi distribution partners. You can also obtain information and answers to frequently asked questions from our Mits

Summary of the content on the page No. 4

Summary of the content on the page No. 5

Instruction Manual Alarm Modems AM and GM series Art-No.: 165590 Version Changes / Additions / Corrections A 09/2005 pdp-ck First Edition Mitsubishi Alarm Modem i

Summary of the content on the page No. 6

II MITSUBISHI ELECTRIC

Summary of the content on the page No. 7

Security Advice Intended Target Audience This manual is aimed exclusively at suitably qualified electrical engineering specialists that are familiar with the safety standards required for electrical engineering and automation. The engi- neering, installation, commissioning, maintenance and testing of devices must only be carried out by qualified electrical technicians. Unless otherwise stated in this manual or other manuals, any intervention in the hardware and software of products must only be

Summary of the content on the page No. 8

IV MITSUBISHI ELECTRIC

Summary of the content on the page No. 9

Contents 1 Mitsubishi Alarm Modems at a Glance 1.1 State-Of-The-Art Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1 1.2 Easy To Retrofit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1 2 Function overview 2.1 Integrated PLC protocols. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1 2.2 Alarming with acknowledgment . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 10

Contents 4.5 Mitsubishi FX at RS485/422 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-5 5 Power supply 6 Operation 7 Configuration and projects 7.1 Initial configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-1 7.2 Loading projects in the MAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-1 7.3 Loading projects remotely on the MAM. . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 11

Mitsubishi Alarm Modem GSM 10 mit2x - 30Rs232 V DC, + max. 6 I/Os 0.7 A 027954 541034 Fax M 1 2 abc def 3 4 ghi 5 jki mno 6 7 qprs 8 tuv wxyz 9 + 0 # E LSE Q Q64AD QX8 QX8 Q C 61 Mitsubishi Alarm Modems at a Glance State-Of-The-Art Communication 1 Mitsubishi Alarm Modems at a Glance Mitsubishi Alarm Modems are new automatic modems with a large data memory, several func- tions and integrated Internet technology. They are designed as intelligent communication com- puters with a 32-bit power CPU an

Summary of the content on the page No. 12

Integrated PLC protocols Function overview 2 Function overview 2.1 Integrated PLC protocols Mitsubishi Alarm Modems can communicate directly with the PLCs of leading manufacturers using the relevant PLC protocol, and access PLC variables, markers and ports via the PLC pro- gramming interface. This can be achieved without having to adapt the PLC program or load a special function block for communication. These protocols are supported:  Mitsubishi Alpha XL  Mitsubishi MELSEC FX1S/FX1N and FX2N/F

Summary of the content on the page No. 13

Function overview Teleservice via PC 2.4 Teleservice via PC A Mitsubishi Alarm Modem can be used to handle the remote maintenance of several controllers via a telephone line. This is usually possible with the program- ming software in use. The variables and I/O ports of the PLC can also be read or written remotely online with the Mitsubishi Alarm Editor (MX-AME). The entire configuration of the Mitsubishi Alarm Modem can be carried out by remote dial-in and the logged data can be read “manually"

Summary of the content on the page No. 14

027954 541034 Overview of the Connectors Installation and Mounting 3 Installation and Mounting 3.1 Overview of the Connectors 3.1.1 Alarm Modem GSM    Fig. 3-1: Overview of all connectors of the Alarm Modem GSM No. Marking Meaning Antenna Plug (FME) for Antenna cable (impendance: 50Ω ) COM1 (RS232) 9pin D-Sub jack COM2 (RS232) 9pin D-Sub plug (only MAM-GM20)  10...30 V DC Power supply (2 screw terminals)  10...30 V DC Power supply (jack) for external power supply  Service Butto

Summary of the content on the page No. 15

027954 541034 Installation and Mounting Overview of the Connectors 3.1.2 Alarm Modem 56k    Fig. 3-2: Overview of all connectors of the Alarm Modem 56k No. Marking Meaning Line Telephone jack RJ11 COM1 (RS232) 9pin D-Sub jack COM2 (RS232) 9pin D-Sub plug (only MAM-AM20) 10...30 V DC Power supply (2 screw terminals)  10...30 V DC Power supply (jack) for external power supply  Service Button  RS 485/422 with MAM-AM24 COM2 (RS485/RS422) 5-pin screw terminal configurable over DIP

Summary of the content on the page No. 16

Meaning of the LEDs Installation and Mounting 3.2 Meaning of the LEDs Antenna Service Power Process Line Data out Modem Mode SIM-Card Push DC 10...30V -+ COM2 (RS232) COM1 (RS232) Power Process Line Data out Modem Mode Fig. 3-3: LEDs on the modem LED Status Meaning Device operational Power (yellow) No power supply Processing in progress: message generation, variable changes etc. Process (red) Normal operation, no processing in progress Connection present Modem is not logged onto the GSM network

Summary of the content on the page No. 17

027954 541034 X X X Mitsubishi Alarm Modem GSM xxxxx xx - xx Xxxxx XX, + xxx. xxx X.X 027954 541034 Installation and Mounting Mounting 3.3 Mounting Mount the modem by pushing or snap fitting it onto a DIN rail (top-hat rail 35 mm). Fig. 3-4: Pull out the black tab on the device using a screwdriver and so the device can snap fit to the DIN rail. You can remove thedevicefromtherail inthesameway. Ensure that the retaining machanism of the modem snaps cleanly and securely into the DIN rail. Fig. 3-5

Summary of the content on the page No. 18

Mitsubishi Alar Modem GSM mit2x Rs232 6 I/Os - DC max. 0.7 027954 541034 m + 10 30 V , A Connecting the GSM antenna (only GM series) Installation and Mounting 3.4 Connecting the GSM antenna (only GM series) First of all find a suitable location for mounting the GSM antenna outside of the control cabinet. In order to find a suitable location with a good reception quality you may use the software MX Mitsubishi Alarm Editor to display the signal quality. Screw the antenna plug into the antenna sock

Summary of the content on the page No. 19

www.tixi.com Tixi Alarm Modem GSM mit2x Rs232 + 6 I/Os 10 - 30 V DC, max. 0.7 A 027954 541034 HG27 Installation and Mounting Inserting the SIM card (only GM series) 3.5 Inserting the SIM card (only GM series) To insert the SIM card in the modem, open the SIM card holder on the Mitsubishi Alarm Modem by pressing the small button on the right of the holder with a pen or a pointed object. Fig. 3-7: Push down the button until the card holder is released You can now carefully pull out the card holder

Summary of the content on the page No. 20

Connection to the Telephone Network (only AM series) Installation and Mounting 3.6 Connection to the Telephone Network (only AM series) Connection to telephone network (PSTN) is established via the included telephone cable and the “Line” jack of the MAM. 1-b2 Abb. 3-9 2-W The Mitsubishi Alarm 3-a 4-b Modem supports the a/b 654321 5-E leads (3 and 4). 6-a2 To get access to your Mitsubishi Alarm Modem, the telephone number of the connection used must be known. 3.6.1 Testing the Telephone Connectio


Alternative user manuals
# User manual Category Download
1 Mitsubishi Electronics MIM-G01 User manual Modem 10
2 Mitsubishi Electronics MIM-A01 User manual Modem 0
3 Mitsubishi Electronics MITSUBISHI MAM MAM-GM20 User manual Modem 4
4 Mitsubishi Electronics MITSUBISHI MAM MAM-GM6 User manual Modem 4
5 Mitsubishi Electronics MITSUBISHI MAM MAM-GM24 User manual Modem 9
6 Mitsubishi Electronics MITSUBISHI MAM MAM-AM20 User manual Modem 0
7 Mitsubishi Electronics MITSUBISHI MAM MAM-AM24 User manual Modem 0
8 Edelbrock 15631 User manual Modem 0
9 3Com 1.024.1644-00 User manual Modem 0
10 3Com OFFICECONNECT 3C886 User manual Modem 5
11 3Com ADSLEthernet User manual Modem 1
12 3Com CableExternal User manual Modem 6
13 Sony GC75 User manual Modem 2
14 Sony SE366 User manual Modem 3
15 Sony MP595 User manual Modem 1