Olympus AX70 user manual

User manual for the device Olympus AX70

Device: Olympus AX70
Category: Microscope & Magnifier
Manufacturer: Olympus
Size: 3.38 MB
Added : 4/24/2014
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Olympus AX70. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Olympus AX70.

For your convenience

If looking through the Olympus AX70 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Olympus AX70 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Olympus AX70 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Olympus AX70 User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Olympus AX70 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Olympus AX70. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

RESEARCH SYSTEM MICROSCOPE
AX70
UNIVERSAL
INFINITY SYSTEM

Summary of the content on the page No. 2

Thereferenc for future mi 1

Summary of the content on the page No. 3

AUTOMATIC OPERATION WORLD CLASS OPTICS ILLUMINATION VERSATILITY HIGH STABILITY USER COMFORT The dramatic progress in biological and medical research demands that microscopes do more than answer today's needs. To be viable, they must also offer the performance potential and system flexibility to accommodate tomorrow's research needs. To date, only one microscope fulfills all these demands – the AX70 Research Microscope from Olympus. Offering uncompromising performance and outstanding system i

Summary of the content on the page No. 4

AX70 and it’s Universal Photo System – the ultimate combination for fully automatic photomicrography. The AX70 and its automatic photomicrography system represent the ideal combination for scientific applications. Using the AX70 together with the U-PHOTO Universal Photo System provides a very advanced level of microscope performance and sophisticated photomicrography capabilities. Combining the mainframe and its corresponding auto focus function with the U-AFPHOTO and motorized units integra

Summary of the content on the page No. 5

Effective solutions to research demands from a flexible system geared to fulfill present and future requirements. The AX70 starts by offering all the advantages of the proprietary UIS optical system to provide the best image quality possible – and adds universal adaptability for rapid changeovers between various microscopic techniques. The specially designed Y-shape frame assures superb operator comfort. A choice of illuminator systems suits a range of different microscopic methods. And the

Summary of the content on the page No. 6

The Olympus UIS optics – The new standard of excellence. 5

Summary of the content on the page No. 7

WORLD CLASS OPTICS Aberration-free image even with Simple modification of microscopic F.N. 26.5 for any microscopic added attachments. systems. technique. Innovative UIS infinity-corrected The major drawback of conventional Super widefield observation tubes optics, such as objectives, telan infinity-corrected optical systems is enable the AX70 to have an extended lenses, eyepieces and other lens units field flatness degradation and coma field of view (F.N. 26.5) for brightfield, completely eli

Summary of the content on the page No. 8

Maximum quality for various microscopy applications. 7

Summary of the content on the page No. 9

RESOLUTION AND CONTRAST IMAGING Bright, high-quality fluorescence reflection phase membrane. lens surfaces and frame. Together images. Appropriate phase-contrast and with dedicated Olympus optical The AX optical system attains the very transmission are ensured for a wide design algorithms, this ensures best brightness and assures crystal- wavelength range for outstanding unmatched image contrast for clear fluorescence images by contrast and image quality. polarized light observation. Used empl

Summary of the content on the page No. 10

A range of illuminator systems for advanced research applications. 9

Summary of the content on the page No. 11

ILLUMINATION VERSATILITY Photoactivation of caged fluorescein. Caged fluorescein labeled tubulin had been introduced in the cell; after exposure to UV light through a slit a photoactivated zone was generated. conventional ultraviolet UV excitation are both required when fluorescence microscopy moves toward multi- staining. However, this requires switching the light source from the conventional mercury burner to a halogen source. The twin-lamp housing configuration on the AX70 makes the switc

Summary of the content on the page No. 12

Structural integrity for vibration resistance, weighty accessories and thermal stability. 11

Summary of the content on the page No. 13

HIGH STABILITY NG108 Left: prior to enhancement Right: VEC+DIC Frame stability – the basis of Heat-resistant light source Vibration-resistant rigidity ensures system flexibility. structure. the best results for Current biological research The power supply represents a electrophysiological experiments. applications require more than a high- source of heat for microscopes. To The AX70’s tripod-like frame design quality microscope. They demand a achieve the best long term thermal offers a wider

Summary of the content on the page No. 14

Maximum operator comfort at all times. 13

Summary of the content on the page No. 15

COMFORTABLE OPERATION The thrombus model in microcirculation of the rat mesentery/ LCPL 20 , Photo magnification 5 , brightfield An extra-wide stage -- ideal for not only allows the operator's forearms experiments and observation of to be supported by the worktable or small animals. bench surface, but also provides more An extra-large 6'' stage offers the ideal working space. As a result, design for examining mice and other micromanipulators can be large specimens. The AX70 also has conveni

Summary of the content on the page No. 16

Automation facilitates research microscopy. 15

Summary of the content on the page No. 17

AUTOMATIC OPERATION Chromosome – 1, 4 and 9 in human metaphase Chromosomes/ Spectrum Orange+FITC+DAPI/ UPLAPO 100 different microscopic methods. The AX70 also includes a motorized filter changer and motorized revolving nosepiece to speed selection of excitation wavelength. In addition, the AX70 allows the operator to affect setting changes. This is achieved through the motorized field stop and aperture stop units, and the motorized filter changeover, which can be used to perform various mic

Summary of the content on the page No. 18

Sophisticated photo and video documentation systems. U-PHOTO Universal Photo System The U-PHOTO Universal Photo System is an automatic photomicrography system that provides fully automatic functions for photomicrography. These include a flexible spot measurement function, a Super FL Auto mode specifically designed for fluorescence photomicrography, and a zoom magnification changeover. The U-AFPHOTO system also features an auto focus mechanism capable of accommodating a wide range of microsco

Summary of the content on the page No. 19

RESEARCH DOCUMENTATION U-AFPHOTO offers auto focus capability for a wide range of microscope techniques. The U-AFPHOTO is equipped with a high-performance auto focus mechanism that accommodates a wide range of objective magnifications (1.25 -100 ), as well as brightfield, darkfield, fluorescence* and Nomarski DIC* observation methods. The focusing speed during ordinary brightfield observation has been raised significantly to achieve focus in only 0.3 - 2 seconds. In addition to the one-shot

Summary of the content on the page No. 20

Fluorescence microscopy dedicated accessories support full research efficiency. AX-REXBA* The use of a dual-band filter allows simultaneous observation of double- stained specimens. With the conventional observation method, photomicrography or image documentation with optimally balanced light intensity is difficult since one of the two fluorochromes may emit fluorescence that is too weak or too strong. However, by simply turning the dial of the AX- REXBA, easy control of the fluorescence balan


Alternative user manuals
# User manual Category Download
1 Olympus FV300 User manual Microscope & Magnifier 97
2 Olympus PM10SP User manual Microscope & Magnifier 18
3 Olympus CKX41 User manual Microscope & Magnifier 489
4 Olympus System Microscope CS41 User manual Microscope & Magnifier 15
5 Olympus RESEARCH STEREOMICROSCOPE SYSTEM szx16 User manual Microscope & Magnifier 35
6 Olympus CX41 User manual Microscope & Magnifier 348
7 Olympus Fluoview FV1000 User manual Microscope & Magnifier 1136
8 Sony DSBK-1501 User manual Microscope & Magnifier 2
9 Sony snt-v User manual Microscope & Magnifier 0
10 Sony HDLA1500 User manual Microscope & Magnifier 4
11 ADIC 6-00026-01 Rev A User manual Microscope & Magnifier 1
12 ATN, Inc. 10x65Z User manual Microscope & Magnifier 2
13 ATN, Inc. Army Mil-Dot User manual Microscope & Magnifier 3
14 Barco PDS-902 User manual Microscope & Magnifier 133
15 Carson HF-66 User manual Microscope & Magnifier 1