Summary of the content on the page No. 1
Plena Two-zone Call Station
Installation and User Instructions
en PLE-2CS
Summary of the content on the page No. 2
Plena Two-zone Call Station | Installation and User Instructions | Important safeguards en | 2 Important safeguards Before installing or operating this product, always read the Safety Instructions, which are available as a separate document (9922 141 7014x). These instructions are supplied together with all equipment that can be connected to the mains. Thank you for choosing a Bosch Security Systems product! Bosch Security Systems | 2008-01 | PLE-2CS en
Summary of the content on the page No. 3
Plena Two-zone Call Station | Installation and User Instructions | Table of contents en | 3 Table of contents Important safeguards ...................................................................................................................................................2 Table of contents ...........................................................................................................................................................3 1. Introduction .............................
Summary of the content on the page No. 4
Plena Two-zone Call Station | Installation and User Instructions | Table of contents en | 4 Intentionally left blank Bosch Security Systems | 2008-01 | PLE-2CS en
Summary of the content on the page No. 5
Plena Two-zone Call Station | Installation and User Instructions | Introduction en | 5 1 Introduction 1.6 Icons 1.6.1 Note icons 1.1 Purpose The icons used in combination with Notes provide extra The purpose of these Installation and User Instructions information about the Note. See the following is to provide information that is required to install, examples: configure and operate a Plena Two-zone Call Station. 1.2 Digital document Note General icon for notes. These Installation and User Ins
Summary of the content on the page No. 6
Plena Two-zone Call Station | Installation and User Instructions | Introduction en | 6 1.7 Conversion tables In this manual, SI units are used to express lengths, masses, temperatures etc. These can be converted to non-metric units using the following information. table 1.1: Conversion of units of length 1 in = 25.4 mm 1 mm = 0.03937 in 1 in = 2.54 cm 1 cm = 0.3937 in 1 ft = 0.3048 m 1 m = 3.281 ft 1 mi = 1.609 km 1 km = 0.622 mi table 1.2: Conversion of units of mass 1 lb = 0.4536 kg 1 kg = 2
Summary of the content on the page No. 7
Plena Two-zone Call Station | Installation and User Instructions | Description en | 7 2 Description The Plena Two-zone Call Station features: • a selectable microphone gain level, a selectable speech filter, and a limiter for improved intelligibility 2.1 The Plena product range • a balanced line level output. See section 2.3.1. The Plena Two-zone Call Station is part of the Plena • two loop-through RJ-45 sockets. See section 2.3.2. product range. Plena provides public address solutions • DIP sw
Summary of the content on the page No. 8
ON 12 3 4 56 7 8 Plena Two-zone Call Station | Installation and User Instructions | Description en | 8 2.4 Controls, connectors and 2.4.2 Bottom side indicators See figure 2.2 for an overview of the controls and indicators at the bottom of the call station: 2.4.1 Top side 1 Configuration settings - A set of DIP switches to See figure 2.1 for an overview of the controls and configure the call station (by setting the microphone indicators on the top side of the call station: gain level, the chi
Summary of the content on the page No. 9
Plena Two-zone Call Station | Installation and User Instructions | Installation en | 9 3 Installation 3.1 Unpack unit 1 Remove the unit from the box, and discard the packaging material according to local regulations. 2 Use your fingernails to carefully peel off the protective plastic film. Do not use sharp or pointed objects. 3.2 Connect unit to PLE-series two-zone mixer (amplifier) 1 Connect the Plena Two-zone Call Station to the PLE-series two-zone mixer or mixer amplifier using a Cat-5
Summary of the content on the page No. 10
Plena Two-zone Call Station | Installation and User Instructions | Installation en | 10 Intentionally left blank Bosch Security Systems | 2008-01 | PLE-2CS en
Summary of the content on the page No. 11
Plena Two-zone Call Station | Installation and User Instructions | Connections en | 11 4 Connections and settings 4.2 Configuration settings Use the DIP switches at the bottom of the call station to set the chime, the momentary or latching speaking 4.1 Connecting multiple call function, the speech filter and the microphone gain. See stations figure 4.2. When the configuration requires more than one call station, use the loop-through RJ-45 sockets on the call 4.2.1 Chime settings stations to
Summary of the content on the page No. 12
ON 12 3 4 56 7 8 Plena Two-zone Call Station | Installation and User Instructions | Connections en | 12 4.2.4 Microphone gain settings See figure 4.2. DIP switches number 6 and 7 are used for setting the microphone gain. 1 = ON-position, 0 = OFF-position. table 4.2: Microphone gain settings DIP switch setting Description (6-7) 0-0 -15 dB 1-0 0 dB 0-1 +6 dB 1-1 +6 dB DIP ON(1) OFF(0) 12 3 456 78(spare) figure 4.2: DIP switches Bosch Security Systems | 2008-01 | PLE-2CS en
Summary of the content on the page No. 13
Plena Two-zone Call Station | Installation and User Instructions | Operation en | 13 5Operation 5.1 Make calls (momentary speaking function) 1 Press the push-to-talk button and keep the button depressed during the business call. 2 Make the business call. 3 Release the push-to-talk button after the business call. 5.2 Make calls (latching speaking function) 1 Shortly press the push-to-talk button to start the figure 5.1: Adjust the output volume business call. 2 Make the business call. 3 Short
Summary of the content on the page No. 14
Plena Two-zone Call Station | Installation and User Instructions | Operation en | 14 Intentionally left blank Bosch Security Systems | 2008-01 | PLE-2CS en
Summary of the content on the page No. 15
Plena Two-zone Call Station | Installation and User Instructions | Technical data en | 15 6 Technical data 6.4 Mechanical Base dimensions (H x W x D), without microphone: 6.1 Electrical 40 x 100 x 235 mm (1.57 x 3.97 x 9.25 in) Voltage range: Stem length (with microphone): 24 V(DC), supplied by PLE-series mixer or mixer 390 mm (15.35 in) amplifier. Cat-5 extension cable length: Current consumption: 5m (16.4 ft) < 30 mA Weight: Approx. 1 kg (2.2 lb) 6.2 Performance Mounting: Nominal sensitivity:
Summary of the content on the page No. 16
Plena Two-zone Call Station | Installation and User Instructions | Technical data en | 16 Intentionally left blank Bosch Security Systems | 2008-01 | PLE-2CS en
Summary of the content on the page No. 17
Summary of the content on the page No. 18
For more information visit www.boschsecuritysystems.com © Bosch Security Systems B.V. Data subject to change without notice 2008-01 | PLE-2CS en