Teledyne 465M user manual

User manual for the device Teledyne 465M

Device: Teledyne 465M
Category: Marine Radio
Manufacturer: Teledyne
Size: 1.27 MB
Added : 7/4/2013
Number of pages: 76
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Teledyne 465M. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Teledyne 465M.

For your convenience

If looking through the Teledyne 465M user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Teledyne 465M on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Teledyne 465M to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Teledyne 465M User manual - Online PDF
Advertisement
« Page 1 of 76 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Teledyne 465M but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Teledyne 465M. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1






INSTRUCTION MANUAL

MODEL 465M
OZONE MONITOR




TELEDYNE ADVANCED POLLUTION INSTRUMENTATION (TELEDYNE API)
9480 Carroll Park Drive
San Diego, CA 92121-5201

TOLL-FREE: 800-324-5190
TEL: 858-657-9800
FAX: 858-657-9816

EMAIL: api-sales@teledyne.com
WEB SITE: http://www.teledyne-api.com/




Copyright 2007-2012 06160D DCN 6409
Teledyne Advanced Pollution Instrumentation 23 MARCH 2012

Summary of the content on the page No. 2

THIS PAGE IS INTENTIONALLY LEFT BLANK

Summary of the content on the page No. 3

SAFETY MESSAGES Important safety messages are provided throughout this manual for the purpose of avoiding personal injury or instrument damage. Please read these messages carefully. Each safety message is associated with a safety alert symbol and placed throughout this manual and inside the instrument. The symbols with messages are defined as follows: WARNING: Electrical Shock Hazard HAZARD: Strong oxidizer GENERAL WARNING/CAUTION: Read the accompanying message for specific infor

Summary of the content on the page No. 4

CONSIGNES DE SÉCURITÉ Des consignes de sécurité importantes sont fournies tout au long du présent manuel dans le but d’éviter des blessures corporelles ou d’endommager les instruments. Veuillez lire attentivement ces consignes. Chaque consigne de sécurité est représentée par un pictogramme d’alerte de sécurité; ces pictogrammes se retrouvent dans ce manuel et à l’intérieur des instruments. Les symboles correspondent aux consignes suivantes : AVERTISSEMENT : Risque de choc électrique D

Summary of the content on the page No. 5

WARRANTY WARRANTY POLICY (02024F) Teledyne Advanced Pollution Instrumentation (TAPI), a business unit of Teledyne Instruments, Inc., provides that: Prior to shipment, TAPI equipment is thoroughly inspected and tested. Should equipment failure occur, TAPI assures its customers that prompt service and support will be available. COVERAGE After the warranty period and throughout the equipment lifetime, TAPI stands ready to provide on-site or in-plant service at reasonable rates similar to

Summary of the content on the page No. 6

THIS PAGE IS INTENTIONALLY LEFT BLANK P/N 06160D DCN6409 Teledyne API Model 465M O Monitor Instruction Manual - Page iv 3

Summary of the content on the page No. 7

TABLE OF CONTENTS 1. INTRODUCTION..........................................................................................................9 1.1. PREFACE..............................................................................................................................................9 2. SPECIFICATIONS AND AGENCY APPROVALS ................................................11 2.1. SPECIFICATIONS..........................................................................................

Summary of the content on the page No. 8

8. DIGITAL COMMUNICATIONS ..............................................................................43 8.1. DIGITAL COMMUNICATIONS OVERVIEW ............................................................................................43 8.2. CHANGING COM PORT HARDWARE CONFIGURATION .......................................................................43 8.3. RS-232 CONFIGURATION.................................................................................................................

Summary of the content on the page No. 9

FIGURES Figure 4-1: M465M Mounting Hole Locations and Dimensions.................................................................16 Figure 4-2. NEMA AC Power Connection to Monitor................................................................................18 Figure 4-3: Pneumatic Connections, Rack Mount Configuration ................................................................19 Figure 4-4: Pneumatic Connections, NEMA Configuration .................................................

Summary of the content on the page No. 10

TABLES Table 4-1: M465M Ventilation Clearances, NEMA Version........................................................................15 Table 4-2: M465M Ventilation Clearances, Rack Mount Version................................................................16 Table 4-3: Status Output Definitions............................................................................................................24 Table 4-4: Relay Functions............................................................

Summary of the content on the page No. 11

1. INTRODUCTION 1.1. Preface Teledyne API is pleased that you have purchased the M465M. We offer a full one year warranty (see Section 2.2) and we at Teledyne API will be pleased to provide you with any support required so that you may utilize our equipment to the fullest extent. We hope you will not experience any problems with the Teledyne API Model 465M (M465M) but if you do, the built-in tests and diagnostics should allow you to quickly and easily find the problem. In addition, our

Summary of the content on the page No. 12

THIS PAGE IS INTENTIONALLY LEFT BLANK P/N 06160D DCN6409 Teledyne API Model 465M O Monitor Instruction Manual - Page 10 3

Summary of the content on the page No. 13

2. SPECIFICATIONS AND AGENCY APPROVALS 2.1. Specifications Measuring principle UV absorption (Beer Lambert Law) Ranges User selectable to any full scale range from: 0-1000 PPM to 0-10,000 PPM 3 3 0-5 g/Nm to 0-50 g/Nm 0-1 wt% to 0-5 wt% 3 Measurement Units PPM, wt%, g/Nm Accuracy  1% of Full Scale Precision/Repeatability  0.5% of Full Scale 3 Display Resolution 1 PPM, 0.001 wt%, 0.01 g/Nm Response Time (95%) <45 seconds to 95% Pressure, Temperature (NTP = 273.15K, 760 Compe

Summary of the content on the page No. 14

2.2. Approvals This section presents Safety and Electromagnetic Compatibility (EMC) compliance approvals for the Model 465M monitor. 2.2.1. Safety IEC 61010-1:2001, Safety requirements for electrical equipment for measurement, control, and laboratory use. CE: 2006/95/EC, Low-Voltage Directive North American: cNEMKO (Canada): CAN/CSA-C22.2 No. 61010-1-04 NEMKO-CCL (US): UL No. 61010-1 (2nd Edition) 2.2.2. EMC EN 61326-1 (IEC 61326-1), Class A Emissions/Industrial Immunity EN 5501

Summary of the content on the page No. 15

3. PRINCIPLE OF OPERATION The detection of ozone molecules is based on absorption of 254 nm UV light due to an internal electronic resonance of the O molecule. The M465M uses a mercury lamp 3 constructed so that a large majority of the light emitted is at the 254nm wavelength. Light from the lamp shines through an absorption cell through which the sample gas is passed. The ratio of the intensity of light passing through the absorption cell and the intensity of light measured by a referen

Summary of the content on the page No. 16

length determines how many molecules are present in the column of gas in the absorption tube. The intensity of light is converted into a voltage by the detector/preamp module. The voltage is converted into a number by a high resolution A/D (analog-to-digital) converter. The digitized signal, along with the other variables, is used by the CPU to compute the concentration using the above formula. P/N 06160D DCN6409 Teledyne API Model 465M O Monitor Instruction Manual - Page 14 3

Summary of the content on the page No. 17

4. GETTING STARTED The M465M is shipped with the following standard equipment: 1. Power cord (Rack mount version only) 2. Instruction manual. Upon receiving the M465M please do the following: 1. Verify that there is no apparent shipping damage. (If damage has occurred please advise shipper first, then Teledyne API.) 4.1. Mechanical Installation (for NEMA 4X Enclosure) Mount the enclosure securely to a vertical surface.  Figure 4-1 shows the locations of the four mounting hole

Summary of the content on the page No. 18

Figure 4-1: M465M Mounting Hole Locations and Dimensions 4.2. Mechanical Installation (19” Rack Version) The Rack Mount version of the M465M was designed to be operated as a bench-top monitor or to be mounted in a standard 19” RETMA instrumentation rack. For rack installations, the four mounting feet should be removed from the bottom of the monitor. 4.2.1. Ventilation Clearance When installing the M465M be sure to leave sufficient ventilation clearance. Table 4-2: M465M Ventilatio

Summary of the content on the page No. 19

4.3. AC Power Connection (for Monitors in NEMA 4X Enclosures) CAUTION Disconnect power to the AC mains before making or removing any electrical connections to the M465M. CAUTION A proper earth ground connection must be made to the receptacle labeled “Earth Ground” on the 3 pin AC connector. Failure to do so may result in a shock hazard and malfunction of the monitor 1. Install a ½” conduit fitting for routing the electrical wiring into the monitor through the hole provided in

Summary of the content on the page No. 20

3. For the NEMA configuration, the electrical connection must be hard-wired to the 3-pin connector on the mainboard labeled J23. AC power connection to the monitor should be made with 12-14 AWG stranded copper wire, connected to the monitor as follows: a. Earth Ground (green): Connect the earth ground wire to the screw terminal lug on the chassis as shown in the Figure below. Do not connect the earth ground wire directly to the PCB connector on the mainboard PCB. b. Line (Black): Conn


Alternative user manuals
# User manual Category Download
1 Teledyne HPM-760 User manual Marine Radio 2
2 Teledyne M100E User manual Marine Radio 0
3 Teledyne M200E and M400E User manual Marine Radio 0
4 Acu-Rite #01088 User manual Marine Radio 0
5 Acu-Rite 02010CDI User manual Marine Radio 2
6 Acu-Rite 972 User manual Marine Radio 0
7 Acu-Rite #02036WB User manual Marine Radio 6
8 Acu-Rite 01502BPDI User manual Marine Radio 0
9 AcuRite Chaney Instrument Company250 User manual Marine Radio 0
10 Adam Equipment CBC SERIES User manual Marine Radio 0
11 ADI Systems AT-201 User manual Marine Radio 239
12 AEG Powertools 8000011647 BAL en User manual Marine Radio 1
13 Albrecht AE-540 User manual Marine Radio 47
14 Ambient Devices WS-0100 User manual Marine Radio 5
15 Ambient Devices WS-0202 User manual Marine Radio 0