Summary of the content on the page No. 1
Pro Weather Station INTRODUCTION
Thank you for selecting the Oregon Scientific™ Weather
Model: WMR86 / WMR86A
Station (WMR86 / WMR86A).
USER MANUAL
The base station is compatible with other sensors. To purchase
additional sensors, please contact your local retailer.
CONTENTS
Introduction ............................................................... 1 Sensors with this logo are compatible with this
unit.
Packaging Contents ................................................. 1
Base Station ..
Summary of the content on the page No. 2
2. MAX/MIN: Read the max / min memory readings; RAIN GAUGE clear readings 3. SELECT: Switch between the different areas 4. LIGHT: Activate backlight 5. / : Increase / decrease values of the selected 2 x AA UM-3 setting; toggle between indoor / outdoor channels 1.5V batteries BACK VIEW 4 x Screws (Type B) 1 x Rain Collector 6 x Washers ACCESSORIES - SENSORS This product can work with up to 3 sensors at any one time to capture outdoor temperature, relative humidity or UV readings in vario
Summary of the content on the page No. 3
1. : Main unit battery low 3. Past 24hrs rainfall is displayed 2. Weather forecast 4. UVI level indicator 5. UVI / barometric pressure (mmHg, inHg or mb) / A. Temperature Area rainfall readings (in or mm) for the current hour B. Humidity / Dew Point Area 6. Maximum UV is displayed C. Wind Speed / Wind Direction / Wind Chill Area 7. UVI / barometric pressure / rainfall historical bar chart D. UVI / Barometer / Rainfall Area display E. Clock / Calendar / Moon Phase Area E Clock / Calendar / Moo
Summary of the content on the page No. 4
1. Unscrew the anemometer from the wind sensor carefully. 2. Insert batteries matching the polarities (+ / -) and replace the anemometer. Press RESET after each battery change. SET UP REMOTE TEMPERATURE / HUMIDITY SENSOR C The remote sensor can collect data from up to 3 channels. To set up the remote sensor: 1. Slide open the battery door. 2. Slide channel switch to select a channel (1, 2, 3). Ensure you use a different channel for each 1. Funnel sensor. 2. Indicator 3. Insert the batteries
Summary of the content on the page No. 5
• Wind direction indicator. Move the direction of the wind indication and verify the icon moves in the same direction . TEMPERATURE / HUMIDITY SENSOR 2. Insert the batteries, matching the polarities (+ / -). 3. Press RESET after each battery change. 4. Close the battery door. NOTE Do not use rechargeable batteries. It is recommended that you use alkaline batteries with this 1. Press SELECT until the selected area icon is in product for longer performance. the upper display area. 2.
Summary of the content on the page No. 6
OR b. Insert 4 type A screws into the holes of the sensor connector. Screw firmly into place, i.e., fence. 1 Slide wind vane onto the smaller end of the sensor 3 2 connector. 4 Water will pool to the center of the cross when the rain gauge is level. If water remains on 1-4, the gauge is not horizontal. If necessary, adjust the level using the screw. IMPORTANT Ensure that the wind sensor is pointing North to enable it to record accurate readings. TEMPERATURE / HUMIDITY SENSOR NOTE For best
Summary of the content on the page No. 7
To enable (and force a signal search) / disable the AUTO SCANNING FUNCTION clock radio reception (clock synchronization): To activate the outdoor temperature and humidity 1. Press SELECT to navigate to the Clock / Calendar / auto-scan function: Moon Phase Area. will show next to the Area. 1. Press SELECT to navigate to the Temperature or 2. Press and hold SEARCH. Humidity Area. will show next to the Area. 2. Press and hold MODE to activate auto-scan. The appears when it is enabled. tem
Summary of the content on the page No. 8
NOTE The unit of all temperature related displays will be The wind level is shown by a series of icons: changed simultaneously. ICON LEVEL DESCRIPTION N/A <2 mph (<4km/h) To view temperature (Current / Min / Max temperature) readings: Light 2-8 mph (3~13 km/h) 1. Press SELECT to navigate to the Temperature Area. will show next to the Area. Moderate 9-25 mph (~14-41 km/h) 2. Press / to select the channel. 3. Press MAX / MIN to toggle between current / MAX / Strong 26-54 mph (~
Summary of the content on the page No. 9
E.g., if it is 10:30 pm now, the bar plotted directly above 2. Press MODE repeatedly to select Barometric -1 shows the reading recorded from 9 to 10 pm and display. -6 shows the reading recorded earlier in the evening, 3. Press and hold MODE to enter the altitude setting. between 4pm-5pm. 4. Press / to increase / decrease the setting value. To view the UV / Barometer / Rainfall readings: 5. Press MODE to confirm the setting. 1. Press SELECT to navigate to the UV / Barometer / Rainfall
Summary of the content on the page No. 10
Accuracy 25% - 40%: +/- 7% REMOTE RAIN GAUGE 40% - 80%: +/- 5% Dimensions 114 x 114 x 145 mm 80% - 90%: +/- 7% (L x W x H) (4.5 x 4.5 x 5.7 inches) Memory Current, Min and Max Weight 241 g (0.54 lbs) without battery Rainfall unit Mm and in RADIO-CONTROLLED / ATOMIC CLOCK Range 0 mm – 9999 mm Synchronization Auto or disabled Accuracy < 15 mm: +/- 1 mm Clock display HH:MM:SS 15 mm to 9999 mm: +/- 7% Hour format 12hr AM/PM or 24hr Memory Past 24hrs, hourly from last Calendar DD/MM or MM/DD memory
Summary of the content on the page No. 11
We EU DECLARATION OF CONFORMITY Name: Oregon Scientific, Inc. Hereby, Oregon Scientific, declares that this Pro Weather th Address: 19861 SW 95 Ave.,Tualatin, Station (models: WMR86 / WMR86A) is in compliance with the essential requirements and other relevant Oregon 97062 USA provisions of Directive 1999/5/EC. A copy of the signed Telephone No.: 1-800-853-8883 and dated Declaration of Conformity is available