Motorola LD-W-1 user manual

User manual for the device Motorola LD-W-1

Device: Motorola LD-W-1
Category: Marine Radio
Manufacturer: Motorola
Size: 0.61 MB
Added : 10/19/2013
Number of pages: 26
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Motorola LD-W-1. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Motorola LD-W-1.

For your convenience

If looking through the Motorola LD-W-1 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Motorola LD-W-1 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Motorola LD-W-1 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Motorola LD-W-1 User manual - Online PDF
Advertisement
« Page 1 of 26 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Motorola LD-W-1 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Motorola LD-W-1. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

n
n
LD-W-1
Lokdecoder für Wechselstrommotoren
n
Motorola-Format
Locomotive Decoder for AC engines
n
Motorola-Format
Décodeur pour locomotive avec moteur alternatif
n
Format-Motorola
Locdecoder voor wisselstroommotoren
n
Motorola-format
Art.-Nr. 22-01-015 C 21 27 00
n
n
n
n
n
LD-G-1 Anleitung
Lokdecoder für Gleichstrommotoren
n
Manual
Motorola-Format
Locomotive Decoder for DC engines
n
Mode d´emploi
Motorola-Format
Décodeur pour locomotive avec moteur continu
n
Handleiding
Format-Motorola
Locdeco

Summary of the content on the page No. 2

n © 07/2002 Tams Elektronik GmbH Alle Rechte, insbesondere das Recht der n Vervielfältigung und Verbreitung sowie der Übersetzung vorbehalten. Vervielfältigungen n und Reproduktionen in jeglicher Form bedürfen der schriftlichen Genehmigung n Deutsch 3 durch die Tams Elektronik GmbH. Technische Änderungen vorbehalten. n English 20 n Français 35 © 07/2002 Tams Elektronik GmbH All rights reserved. No part of this n Nederlands 51 publication may be reproduced or transmitted in any form or by any mea

Summary of the content on the page No. 3

English LD-G-1 / LD-W-1 Table of contents How to use this manual 21 Intended use 21 Safety instructions 22 EMC declaration 24 Information: Motorola I and Motorola II format 24 Operation overview 25 Technical specifications 26 Checking the package contents 26 Required tools and consumables 27 Safe and correct soldering 27 Performing a visual check 28 Mounting the locomotive decoder 28 Setting the locomotive decoder 30 Operation 32 FAQ 33 Manufacturer's note 34 Certification 34 Conditional warrant

Summary of the content on the page No. 4

LD-G-1 / LD-W-1 English How to use this manual If you have no specialist technical training, this manual gives step-by- step instructions for safe and correct fitting of the module, and operation. Before you start, we advise you to read the whole manual, particularly the chapter on safety instructions and the FAQ chapter. You will then know where to take care and how to prevent mistakes which take a lot of effort to correct. Keep this manual safely so that you can solve problems in the future. I

Summary of the content on the page No. 5

English LD-G-1 / LD-W-1 Safety instructions Mechanical hazards Cut wires can have sharp ends and can cause serious injuries. Watch out for sharp edges when you pick up the PCB. Visibly damaged parts can cause unpredictable danger. Do not use damaged parts: recycle and replace them with new ones. Electrical hazards § Do not touch powered, live components. § Do not touch conducting components which are live due to malfunction. § Avoid short circuits. § Do not connect the circuit to a higher voltag

Summary of the content on the page No. 6

LD-G-1 / LD-W-1 English Fire risk Touching flammable material with a hot soldering iron can cause life- threatening fire, burns and toxic smoke. Connect your soldering iron or soldering station only when actually needed. Use the correct soldering iron or station and never leave a hot soldering iron or station unattended. Thermal danger A hot soldering iron or liquid solder accidentally touching your skin can cause skin burns. As a precaution: § use a heat-resistant mat during soldering, § always

Summary of the content on the page No. 7

English LD-G-1 / LD-W-1 EMC declaration This product is developed in accordance with the European standards EN 55014 and EN 50082-1, tested corresponding to the EC - directive 89/336/EWG (EMVG of 09/11/1992, electromagnetic tolerance) and meets legal requirements. To guarantee the electromagnetic tolerance you must take the following precautions: § Connect the transformer only to an approved mains socket installed by an authorised electrician. § Make no changes to the original parts and accurate

Summary of the content on the page No. 8

LD-G-1 / LD-W-1 English Operation overview The decoder is designed for operation in Motorola I or II format and can be adjusted to one of 255 adresses. It evaluates the digital data sent by the central unit to its address and transmitts it to the locomotive. Function speed level and direction of motion The speed level set at the central unit and the change-direction command are transmitted to the locomotive by the decoder. At a direction change the existing direction of travel is not saved, so t

Summary of the content on the page No. 9

English LD-G-1 / LD-W-1 mode the velocity of all speed levels is reduced to ca. 50 % compared to the standard velocity. The accessories connected to the output switched by the auxiliary function F4 are switched together with the shunting gear. As soon as the shunting gear is switched on, any acceleration or brake delay settings are deactivated. By attaching a solder bridge the shunting gear can be deactivated permantly. Restrictions in Motorola I format The auxiliary functions F1 to F4 are not a

Summary of the content on the page No. 10

LD-G-1 / LD-W-1 English Required tools and consumables Make sure you have the following tools, equipment and materials ready for use: § a heat-resistant mat and a soldering iron stand with tip-cleaning sponge § a small side cutter and wire stripper § an electronic soldering iron (max. 30 Watt) with a fine tip § tin solder (0,5 mm. diameter) and wire (diameter: > 0,08 mm²) Safe and correct soldering Caution: ! Incorrect soldering can cause fires (through excessive heat). Avoid this danger by read

Summary of the content on the page No. 11

English LD-G-1 / LD-W-1 Performing a visual check Damaged materials can cause injury. Parts damaged during transit can also be dangerous.Check the module for damage, missing parts or poor soldering. If you find damage, return the module for exchange. Mounting the locomotive decoder Open the locomotive housing. Locate the position for the decoder. Disconnect the motor from the rail current collector respectively the change-over switch from the motor and rails if you have a locomotive with electro

Summary of the content on the page No. 12

LD-G-1 / LD-W-1 English fig. 3a) or you must connect the second side of the lamps according to fig. 3b to the return conductor (point X3 on the front of the decoder). Connect other accessories (e.g. smoke generator, cab lighting), which are switched by the functions F1 to F4, to the points X7 to X10 (front of the decoder). You can connect the second side of the accessories either to the return conductor (point X3) or to locomotive ground. If connecting the accessory to locomotive ground you must

Summary of the content on the page No. 13

English LD-G-1 / LD-W-1 You can connect several LEDs in parallel to each output. In this case every LED must have a series resistor of its own. If you connect several LEDs to one output in series, only one series resistor is needed. The number of LEDs connected in series to one output depends on the digital voltage. You can determine the number of the LEDs that can be connected in series to one output from the following formula: (number of LEDs + 2) x 1,5 < digital voltage Fixing the locomotive

Summary of the content on the page No. 14

LD-G-1 / LD-W-1 English § Standard or second velocity characteristics § Shunting gear active or inactive § Fast, medium or slow acceleration and brake delay The setting of the delay can be combined with any setting of the velocity characteristic and the shunting gear. The setting is made by attaching solder bridges to X17 (on the front of the decoder, underneath the IC U1) and to X20 (on the front of the decoder, to the left of IC U1). The assignment is as follows: Connection Operation X17 Pin 1

Summary of the content on the page No. 15

English LD-G-1 / LD-W-1 The solder pad "4" is identical with connecting point X18. If for one address two connections to solder pad 4 are given, two connections to point X18 must be made. ! Caution: Use a soldering iron with a small tapered point and max. 30 Watt to make the solder bridges. Take special care to avoid short circuits. If necessary, check the solder bridges with a magnifiying glass to make sure that the solder bridges are closed correctly and solder has not short-circuited adjacent

Summary of the content on the page No. 16

LD-G-1 / LD-W-1 English FAQ § Parts are getting too hot and/or start to smoke. Disconnect the system from the mains immediately! ! Possible cause: one or more connections are soldered incorrectly. à Check the connections. Possible cause: The connection of the motor is connected to locomotive ground. à Disconnect the connection from locomotive ground. § The locomotive lighting does not correspond to its direction of travel. Possible cause: The forward and backward light connections have been ex

Summary of the content on the page No. 17

English LD-G-1 / LD-W-1 relevant papers. Domestic appliances assembled from a kit are deemed industrial products and must comply with health and safety regulations. Certification This product conforms with the EC- directive 89/336/EWG on electromagnetic radiation and is therefore CE certified. Conditional warranty This product is guaranteed for two years. The warranty includes free repair if the problem is due to material failure or incorrect assembly of the module by us. We guarantee the quali

Summary of the content on the page No. 18

LD-G-1 / LD-W-1 Einstellung der Adresse / Adjusting the address Réglage de l’adresse / Instellen van het adres Beispiel: Einstellung der Adresse "107" Example: Adjusting the address "107" Exemple: Réglage de l´adresse "107" Voorbeeld: Instellen van adres "107" Adresse Lötfeld - Soldering field Adresse Lötfeld - Soldering field Address Plots d´une rangé Address Plots d´une rangé Adresse Soldeerpunten Adresse Soldeerpunten Adres Adres X14 X16 X15 X13 X14 X16 X15 X13 1 2-3 2-3 2-4 2-4 21 2-3 1-2 1-

Summary of the content on the page No. 19

LD-G-1 / LD-W-1 Adresse Lötfeld - Soldering field Adresse Lötfeld - Soldering field Address Plots d´une rangé Address Plots d´une rangé Adresse Soldeerpunten Adresse Soldeerpunten Adres X14 X16 X15 X13 Adres X14 X16 X15 X13 41 -- -- 1-2 2-3 77 -- 2-3 1-2 -- 42 -- 1-2 2-4 2-3 78 -- 2-4 1-2 2-3 43 -- 2-4 2-4 2-3 79 -- -- 1-2 -- 44 2-3 1-2 2-4 2-3 80 2-4 2-4 2-4 2-4 45 1-2 2-4 1-2 1-2 81 2-4 2-3 2-4 2-4 46 -- 2-3 1-2 1-2 82 1-2 2-4 2-4 1-2 47 -- 2-4 1-2 1-2 83 2-3 1-2 1-2 -- 48 2-4 1-2 2-4 2-4 84 2

Summary of the content on the page No. 20

LD-G-1 / LD-W-1 Adresse Lötfeld - Soldering field Adresse Lötfeld - Soldering field Address Plots d´une rangé Address Plots d´une rangé Adresse Soldeerpunten Adresse Soldeerpunten Adres X14 X16 X15 X13 Adres X14 X16 X15 X13 113 2-4 2-3 2-4 1-2 149 2-4 2-4 1-2 2-3 114 2-4 2-3 2-3 1-2 150 1-2 2-4 1-2 2-3 115 2-4 2-3 2-4 -- 151 2-4 1-2 1-2 2-3 116 2-4 2-3 2-3 -- 152 1-2 1-2 1-2 2-3 117 1-2 2-3 2-4 1-2 153 2-4 2-4 2-4 -- 118 1-2 2-3 2-3 1-2 154 1-2 2-4 2-4 -- 119 1-2 2-3 2-4 -- 155 2-4 1-2 2-4 -- 12


Alternative user manuals
# User manual Category Download
1 Motorola EM1000 User manual Marine Radio 431
2 Motorola FD-1 User manual Marine Radio 2
3 Motorola IC-T81E User manual Marine Radio 4
4 Motorola HF-SSB User manual Marine Radio 11
5 Motorola CDM1250 User manual Marine Radio 18
6 Motorola W510 User manual Marine Radio 5
7 Motorola IC-T81A User manual Marine Radio 4
8 Acu-Rite #01088 User manual Marine Radio 0
9 Acu-Rite 02010CDI User manual Marine Radio 2
10 Acu-Rite 972 User manual Marine Radio 0
11 Acu-Rite #02036WB User manual Marine Radio 6
12 Acu-Rite 01502BPDI User manual Marine Radio 0
13 AcuRite Chaney Instrument Company250 User manual Marine Radio 0
14 Adam Equipment CBC SERIES User manual Marine Radio 0
15 ADI Systems AT-201 User manual Marine Radio 239