AEG Powertools 8000011647 BAL en user manual

User manual for the device AEG Powertools 8000011647 BAL en

Device: AEG Powertools 8000011647 BAL en
Category: Marine Radio
Manufacturer: AEG Powertools
Size: 0.42 MB
Added : 8/10/2013
Number of pages: 8
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for AEG Powertools 8000011647 BAL en. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with AEG Powertools 8000011647 BAL en.

For your convenience

If looking through the AEG Powertools 8000011647 BAL en user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual AEG Powertools 8000011647 BAL en on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual AEG Powertools 8000011647 BAL en to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
AEG Powertools 8000011647 BAL en User manual - Online PDF
Advertisement
« Page 1 of 8 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual AEG Powertools 8000011647 BAL en but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to AEG Powertools 8000011647 BAL en. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Kommunikationszubehör
für USV PROTECT C. / C. R / 1. / 1.M
Communication accessory
for UPS PROTECT C. / C. R / 1. / 1.M
Einsteckkarte pot.-freie Kontakte
Slotcard potential - free contacts
AEG Power Solutions GmbH
Änderung / Revision 03 / Schneider
Datum / Date 05 / 2008
Betriebsanleitung
Operating instructions
8000011647 BAL en

Summary of the content on the page No. 2

Summary of the content on the page No. 3

Settings of Jumper on AS/400 ( Ver01688-04 ) 1 . Feature of the AS/400 card (Ver01688-04) AS/400 (Ver01688-04) card provides shutdown and monitoring of UPS status through a relay dry-contact signal as previous version, to meet different application requirement, the AS/400 (Ver01688-04) card is capable of selection the status of the dry-contact signal (active close or active open) by jumper setting. This document describes the logical connection implemented on the card and the definitio

Summary of the content on the page No. 4

Accordingly, if pin1 short-circuit with pin2 via the jumper, the status of dry contact signal will be ACTIVE CLOSE, refer to Fig 2. When the signal is active, the signal pin on the DB9 connector will CONNECT with the common pin (pin5) via the relay. 1 1 1 2 2 UPS FAIL 2 3 3 3 1 JP2 BYPASS RY02 JP6 JP5 RY05 ALARM 6 1 2 2 BATTERY LOW 1 3 2 7 JP4 3 RY01 3 UPS ON JP3 RY03 8 4 LINE LOSS 1 COMMON 2 9 3 5 JP1 RY04 Fig. 2 Connection for ACTIVE CLOSE If Pin3 short-circuit with Pin2 via the jumpe

Summary of the content on the page No. 5

3 . Settings of jumper on the card Please refer to Fig 4, the 3-pin connectors can be easily found just near to the relay. Fig. 4 The AS400 card (Ver01688-04) There are 2 white silk screen rectangle envelop each 3pin connector, a big rectangle envelop the whole connector, a smaller one envelop 2pin of the connector as shown in Fig. 5. Fig. 5 Two white silk screen rectangle envelop each 3-pin connector Relay card Page 3 Release: May 200

Summary of the content on the page No. 6

To achieve ACTIVE CLOSE dry-contact signal, the jumper should connect the 2 pins enveloped by the small silk screen rectangle as shown in Fig. 6. Fig. 6 Jumper setting for ACTIVE CLOSE Fig. 7 Jumper setting for ACTIVE OPEN Relay card Page 4 Release: May 2008

Summary of the content on the page No. 7

To achieve ACTIVE OPEN dry-contact signal, the jumper should connect the middle pin and the rest pin does not enveloped by the small silk screen rectangle as shown in Fig. 7. The default setting of the jumper is ACTIVE CLOSE. 4 . Pin description Pin assignment Description 1 UPS failure 2 Summary alarm ( signal of pins 1, 7 and 9 ) 3 not connected 4 5 Common ground for pins 1, 2, 6, 7, 8 and 9 6 Bypass active 7 Battery low 8 UPS on 9 Utility Failure Pin 1: UPS fault Battery

Summary of the content on the page No. 8

Guarantee Certificate Type : …….……………….…...................................................... Serial no. : ……………….….…..……………............................... Date of purchase : ………………...........……………………........ Dealer Stamp / Signature Errors and changes excepted. Emil-Siepmann-Straße 32 59581 Warstein - Belecke Germany Tel.: +49 (0) 180 523 4787 Fax: +49 (0) 180 523 4789 www.aegpartnernet.com Operating instructions 8000011647_03 BAL, en 7


Alternative user manuals
# User manual Category Download
1 Acu-Rite #01088 User manual Marine Radio 0
2 Acu-Rite 02010CDI User manual Marine Radio 2
3 Acu-Rite 972 User manual Marine Radio 0
4 Acu-Rite #02036WB User manual Marine Radio 6
5 Acu-Rite 01502BPDI User manual Marine Radio 0
6 AcuRite Chaney Instrument Company250 User manual Marine Radio 0
7 Adam Equipment CBC SERIES User manual Marine Radio 0
8 ADI Systems AT-201 User manual Marine Radio 239
9 Albrecht AE-540 User manual Marine Radio 47
10 Ambient Devices WS-0100 User manual Marine Radio 5
11 Ambient Devices WS-0202 User manual Marine Radio 0
12 Aiphone MC-60/4B User manual Marine Radio 0
13 Aiphone NA-T/A User manual Marine Radio 0
14 Aiphone LE-SS/LE-SSR User manual Marine Radio 0
15 Aiphone IE-SSR User manual Marine Radio 0