Emerson 1066 Liquid Analytical Transmitter 1066 user manual

User manual for the device Emerson 1066 Liquid Analytical Transmitter 1066

Device: Emerson 1066 Liquid Analytical Transmitter 1066
Category: Marine Instruments
Manufacturer: Emerson
Size: 6.58 MB
Added : 4/1/2014
Number of pages: 20
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Emerson 1066 Liquid Analytical Transmitter 1066. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Emerson 1066 Liquid Analytical Transmitter 1066.

For your convenience

If looking through the Emerson 1066 Liquid Analytical Transmitter 1066 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Emerson 1066 Liquid Analytical Transmitter 1066 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Emerson 1066 Liquid Analytical Transmitter 1066 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Emerson 1066 Liquid Analytical Transmitter 1066 User manual - Online PDF
Advertisement
« Page 1 of 20 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Emerson 1066 Liquid Analytical Transmitter 1066 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Emerson 1066 Liquid Analytical Transmitter 1066. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

1066 Liquid Analytical Transmitter
Instruction Sheet 1066
LIQ_MAN_ABR_1066-CT-HT-FF-FI July 2013
ESSENTIAL INSTRUCTIONS
Read this page before proceeding!
Emerson designs, manufactures, and tests its Rosemount
Analytical products to meet many national and international
standards. Because these instruments are sophisticated
technical products, you must properly install, use, and main-
tain them to ensure they continue to operate within their
normal specifications. The following instructions must b

Summary of the content on the page No. 2

1066 Instruction Sheet July 2013 LIQ_MAN_ABR_1066-CT-HT-FF-FI QUICK START GUIDE – 1066 Liquid Analytical Transmitter 1. For mechanical installation instructions, see page 8 for panel mounting and page 9 for pipe or wall mounting. 2. Wire the sensor to the main circuit board. See page 10 for wiring instructions. Refer to the sensor instruction sheet for additional details. Make loop power connections. 3. Once connections are secured and verified, apply DC loop power to the transmitter. 4. When

Summary of the content on the page No. 3

Instruction Sheet 1066 LIQ_MAN_ABR_1066-CT-HT-FF-FI July 2013 Specifications GENERAL SPECIFICATIONS Case: Polycarbonate. IP66 (CSA, FM), NEMA 4X (CSA) Dimensions: Overall 155 x 155 x 131mm (6.10 x 6.10 x 5.15 in.). Cutout: 1/2 DIN 139mm x 139mm (5.45 x 5.45 in.) Conduit openings: Six. Accepts PG13.5 or 1/2 in. conduit fittings Display: Monochromatic graphic liquid crystal display. No backlight. 128 x 96 pixel display resolution. Active display area: 58 x 78mm (2.3 x 3.0 in.). All fields of the m

Summary of the content on the page No. 4

1066 Instruction Sheet July 2013 LIQ_MAN_ABR_1066-CT-HT-FF-FI Input: One isolated sensor input. Measurement choices of Vdc (30 Vdc for intrinsically safe operation). The graph pH/ORP, resistivity/conductivity/TDS, % concentration, shows the supply voltage required to maintain 12 Vdc total and free chlorine, monochloramine, dissolved oxy- (upper line) and 30 Vdc (lower line) at the transmitter ter- gen, dissolved ozone, and temperature. For contacting minals when the current is 22 mA. conductivit

Summary of the content on the page No. 5

Instruction Sheet 1066 LIQ_MAN_ABR_1066-CT-HT-FF-FI July 2013 Specifications CONTINUED CONTACTING CONDUCTIVITY Performance Specifications Measurement Range: see table below Input filter: time constant 1 - 999 sec, default 2 sec. Response time: 3 seconds to 95% of final reading using the default input filter Recommended Sensors for Conductivity All Rosemount Analytical ENDURANCE Model 400 series conductivity sensors (Pt 1000 RTD) and Model 410VP 4- electrode sensor. PERFORMANCE SPECIFICATIONS R

Summary of the content on the page No. 6

1066 Instruction Sheet July 2013 LIQ_MAN_ABR_1066-CT-HT-FF-FI Specifications CONTINUED TOROIDAL CONDUCTIVITY Performance Specifications Measurement Range: see table below Input filter: time constant 1 - 999 sec, default 2 sec. Response time: 3 seconds to 95% of final reading Recommended Sensors for Conductivity All Rosemount Analytical submersion/immersion and flow-through toroidal sensors. PERFORMANCE SPECIFICATIONS Recommended Range - Toroidal Conductivity Model 1 mS/cm

Summary of the content on the page No. 7

Instruction Sheet 1066 LIQ_MAN_ABR_1066-CT-HT-FF-FI July 2013 Installation UNPACKING AND INSPECTION Inspect the shipping container. If it is damaged, contact the shipper immediately for instructions. Save the box. If there is no apparent damage, unpack the container. Be sure all items shown on the packing list are present. If items are miss- ing, notify Rosemount Analytical immediately. INSTALLATION General Information 1. Although the transmitter is suitable for outdoor use, installation is dire

Summary of the content on the page No. 8

1066 Instruction Sheet July 2013 LIQ_MAN_ABR_1066-CT-HT-FF-FI FIGURE 3. Panel Mounting Dimensions 8

Summary of the content on the page No. 9

Instruction Sheet 1066 LIQ_MAN_ABR_1066-CT-HT-FF-FI July 2013 FIGURE 4. Pipe and wall mounting dimensions (Mounting bracket PN: 23820-00) 9

Summary of the content on the page No. 10

1066 Instruction Sheet July 2013 LIQ_MAN_ABR_1066-CT-HT-FF-FI FIGURE 5. Contacting and Toroidal Conductivity sensor wiring to 1066 circuit board (1066-C and 1066-T) 10

Summary of the content on the page No. 11

Instruction Sheet 1066 LIQ_MAN_ABR_1066-CT-HT-FF-FI July 2013 FIGURE 6. CSA Installation 11 SCHEMATIC, INSTALLATION MODEL 1066 XMTR, (CSA)

Summary of the content on the page No. 12

1066 Instruction Sheet July 2013 LIQ_MAN_ABR_1066-CT-HT-FF-FI FIGURE 7. CSA Installation 12 SCHEMATIC, INSTALLATION MODEL 1066 XMTR, (CSA)

Summary of the content on the page No. 13

Instruction Sheet 1066 LIQ_MAN_ABR_1066-CT-HT-FF-FI July 2013 FIGURE 8. CSA Installation 13 SCHEMATIC, INSTALLATION MODEL 1066 XMTR, (CSA)

Summary of the content on the page No. 14

1066 Instruction Sheet July 2013 LIQ_MAN_ABR_1066-CT-HT-FF-FI FIGURE 9. CSA Label Information 14 LABEL, INFO, 1066 CSA

Summary of the content on the page No. 15

Instruction Sheet 1066 LIQ_MAN_ABR_1066-CT-HT-FF-FI July 2013 FIGURE 10. ATEX, IECEx Label Information 15 LABEL, INFO, 1066 ATEX 9241717-00

Summary of the content on the page No. 16

1066 Instruction Sheet July 2013 LIQ_MAN_ABR_1066-CT-HT-FF-FI FIGURE 11. FM installation 16 SCHEMATIC, INSTALLATION MODEL 1066 XMTR, (FM)

Summary of the content on the page No. 17

Instruction Sheet 1066 LIQ_MAN_ABR_1066-CT-HT-FF-FI July 2013 FIGURE 12. FM Installation 17 SCHEMATIC, INSTALLATION MODEL 1066 XMTR, (FM)

Summary of the content on the page No. 18

1066 Instruction Sheet July 2013 LIQ_MAN_ABR_1066-CT-HT-FF-FI FIGURE 13. FM installation 18 SCHEMATIC, INSTALLATION MODEL 1066 XMTR, (FM)

Summary of the content on the page No. 19

Instruction Sheet 1066 LIQ_MAN_ABR_1066-CT-HT-FF-FI July 2013 FIGURE 14. FM label information 19 LABEL, INFO, 1066 FM

Summary of the content on the page No. 20

1066 Instruction Sheet July 2013 LIQ_MAN_ABR_1066-CT-HT-FF-FI facebook.com/EmersonRosemountAnalytical AnalyticExpert.com Credit Cards for U.S. Purchases Only. twitter.com/RAIhome youtube.com/user/RosemountAnalytical Emerson Process Management ©2013 Rosemount Analytical, Inc. All rights reserved. 2400 Barranca Parkway The Emerson logo is a trademark and service mark of Emerson Electric Co. Brand name is a mark Irvine, CA 92606 USA of one of the Emerson Process Management family of companies. All


Alternative user manuals
# User manual Category Download
1 Emerson Digital Controller Valves 788 DVC User manual Marine Instruments 31
2 Emerson Four-electrode Conductivity Sensor 410VP User manual Marine Instruments 0
3 Emerson FCL with 1050 Analyzer 1056 User manual Marine Instruments 149
4 Emerson Four-electrode Conductivity Sensor PN 51A-410VP User manual Marine Instruments 0
5 Emerson ENDURANCE Conductivity Sensor 404 User manual Marine Instruments 1
6 Emerson ENDURANCE Conductivity Sensor PN 51A-404 User manual Marine Instruments 1
7 Emerson FCL with 1050 Analyzer PN 51-FCL-1056 User manual Marine Instruments 12
8 Emerson Mass Flow Transmitter 3095 User manual Marine Instruments 34
9 Emerson Multiport Flow Selector I-0168 User manual Marine Instruments 6
10 Emerson pH/ORP Analyzer/Controller 54e User manual Marine Instruments 3
11 Emerson pH/ORP Analyzer/Controller PN 51A-54epH User manual Marine Instruments 3
12 Emerson Mass Flow Transmitter 00825-0100-4716 User manual Marine Instruments 2
13 Emerson Rosemount Pressure Transmitter 3051S User manual Marine Instruments 58
14 Emerson pH/ORP Analyzer/Controller 54e pH User manual Marine Instruments 18
15 Emerson Tank Contents Transmitter MAS 2600 User manual Marine Instruments 115
16 Sony SSM-930 User manual Marine Instruments 3
17 Sony SSM-175A User manual Marine Instruments 0
18 Attwood 8M004689 User manual Marine Instruments 0
19 Attwood 99515-1 User manual Marine Instruments 0
20 Attwood 99510-1 User manual Marine Instruments 0