Teledyne 465L user manual

User manual for the device Teledyne 465L

Device: Teledyne 465L
Category: Marine Instruments
Manufacturer: Teledyne
Size: 0.84 MB
Added : 4/1/2014
Number of pages: 92
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Teledyne 465L. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Teledyne 465L.

For your convenience

If looking through the Teledyne 465L user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Teledyne 465L on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Teledyne 465L to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Teledyne 465L User manual - Online PDF
Advertisement
« Page 1 of 92 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Teledyne 465L but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Teledyne 465L. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 6

Teledyne API Model 465L O Monitor Operation Manual 3 CONSIGNES DE SÉCURITÉ Des consignes de sécurité importantes sont fournies tout au long du présent manuel dans le but d’éviter des blessures corporelles ou d’endommager les instruments. Veuillez lire attentivement ces consignes. Chaque consigne de sécurité est représentée par un pictogramme d’alerte de sécurité; ces pictogrammes se retrouvent dans ce manuel et à l’intérieur des instruments. Les symboles correspondent aux consignes sui

Summary of the content on the page No. 7

Teledyne API Model 465L O Monitor Operation Manual 3 ABOUT THIS MANUAL This manual is comprised of multiple documents as listed below. Part Name/Description Number 05590 M465L Operation Manual (this manual) 05919 Rack Mount Spare Parts List (integrated into this manual as Section 12.1) 05910 NEMA Spare Parts List (integrated into this manual as Section 12.2) NOTE We recommend that this manual be read in its entirety before any attempt is made to operate the instrument. 05509F

Summary of the content on the page No. 8

Teledyne API Model 465L O Monitor Operation Manual 3 REVISION HISTORY M465L Operation Manual, PN05509 2012 May 09, Rev F, DCN 6409: technical and administrative updates 2011 August 2, Rev E, DCN 6198: technical and administrative updates 2009 October, Rev D, DCN 5522: technical and administrative updates 2009 October, Rev D, DCN 5522: technical and administrative updates 2009 June, Rev C, DCN 5456: administrative udpates 2009 February, Rev B, DCN 5371: administrative updates 2007, Rev

Summary of the content on the page No. 9

TABLE OF CONTENTS ABOUT THIS MANUAL.........................................................................................i SAFETY MESSAGES...........................................................................................ii ABOUT TELEDYNE ADVANCED POLLUTION INSTRUMENTATION (TAPI).....I 1. INTRODUCTION..........................................................................................13 1.1. PREFACE.............................................................................

Summary of the content on the page No. 10

Teledyne API Model 465L O Monitor Operation Manual 3 7.1.4. Concentration Alarm Status/Reset.................................................................40 7.1.5. Status LEDs ...................................................................................................41 7.2. FRONT PANEL MENUS..............................................................................41 7.2.1. Menu Navigation Basics................................................................................4

Summary of the content on the page No. 11

Teledyne API Model 465L O Monitor Operation Manual 3 10.1.2. Interconnect Diagram .................................................................................79 10.2. TROUBLESHOOTING USING FRONT PANEL STATUS LED’S OR STATUS OUTPUTS 80 10.2.1. Sensor OK ...................................................................................................81 10.2.2. Invalid Reading ...........................................................................................81 10.2.3. Check

Summary of the content on the page No. 12

Teledyne API Model 465L O Monitor Operation Manual 3 Figure 9-3: Sensor Detail.................................................................................72 Figure 9-4: Mainboard – Analog Output Configuration.................................74 Figure 10-1: Pneumatic Diagram, 3 Stream Configuration...........................78 Figure 10-2: Interconnect Diagram .................................................................79 x 05509F DCN6409

Summary of the content on the page No. 13

Teledyne API Model 465L O Monitor Operation Manual 3 TABLES Table 4-1: Status Output Definitions ..............................................................30 Table 4-2: Relay Functions for Single Stream Config...................................31 Table 4-3: Relay Functions for Multi-Stream Configs ...................................31 Table 4-4: Multi-Stream Relays .......................................................................32 Table 7-1: Alarm LED’s ...................

Summary of the content on the page No. 14

Teledyne API Model 465L O Monitor Operation Manual 3 This page intentionally left blank. xii 05509F DCN6409

Summary of the content on the page No. 15

1. INTRODUCTION 1.1. Preface The Teledyne API Model 465L is a UV photometric ozone monitor designed and manufactured for single/multi-channel industrial hygiene ozone analysis. It is a very stable analyzer, ideal for critical low-level PPM safety and process applications. Whether you have selected the rack mount or wall mount unit in NEMA 4X enclosure, the M465L is designed to be highly reliable and simple to operate with easy setup and user-friendly menu driven software that can also be s

Summary of the content on the page No. 16

Teledyne API Model 465L O Monitor Operation Manual 3 This page intentionally left blank. 14 05509F DCN6409

Summary of the content on the page No. 17

2. SPECIFICATIONS AND AGENCY APPROVALS 2.1. Specifications User selectable to any full scale range from: 1 PPM to 500 PPM Ranges 1000 PPB to 10,000 PPB 3 3 2000 µg/m to 10,000 µg/m 100 PPHM to 10,000 PPHM (optional configuration) 3 PPM, PPB, µg/m , PPHM (optional Measurement Units configuration) Zero Noise < .0015 PPM (rms) Span Noise < .5% of reading (rms) (above 0.1 PPM) Lower Detectable Limit < .003 PPM (rms) Accuracy +/- 1% of full scale range <30 sec Response Time (95%

Summary of the content on the page No. 18

Teledyne API Model 465L O Monitor Operation Manual 3 Analog Output, Voltage Mode 0 - 5V Isolated Analog Output, 4- Maximum voltage between outputs and ground 20mA Mode 60V peak System OK Status Relay SPDT (Form C) Dry Contact, 250 VAC, 5A SPDT (Form C) Dry Contact, 250 VAC, 5A (x2, Global Alarm Relays HI and HI-HI) 6 - SPST Dry Contact, 50VDC, 250mA Resistive Instrument Status Outputs Load Multi-Stream Specifications: Minimum Stream Duration (Cycle Time) 1.0 min Stream Alarm Rela

Summary of the content on the page No. 1





OPERATION MANUAL


MODEL 465L
OZONE MONITOR







Teledyne Advanced Pollution Instrumentation (TAPI)
9480 Carroll Park Road
San Diego, CA 92121-5201

Phone: 800-324-5190 (toll free in North America)
858-657-9800 (direct)
FAX: 858-657-9816
EMAIL: api-sales@teledyne.com
WEB SITE: http://www.teledyne-api.com/



© 2007-2012 TAPI 05509F DCN6409
Teledyne Advanced Pollution Instrumentation 09 May 2012

Summary of the content on the page No. 2

Summary of the content on the page No. 3

ABOUT TELEDYNE ADVANCED POLLUTION INSTRUMENTATION (TAPI) Teledyne Advanced Pollution Instrumentation, Inc. (TAPI) is a worldwide market leader in the design and manufacture of precision analytical instrumentation used for air quality monitoring, continuous emissions monitoring, and specialty process monitoring applications. Founded in San Diego, California, in 1988, TAPI introduced a complete line of Air Quality Monitoring (AQM) instrumentation, which comply with the United States Environm

Summary of the content on the page No. 4

This page intentionally left blank. ii 05509F DCN6409

Summary of the content on the page No. 5

IMPORTANT SAFETY INFORMATION Important safety messages are provided throughout this manual for the purpose of avoiding personal injury or instrument damage. Please read these messages carefully. Each safety message is associated with a safety alert symbol and placed throughout this manual and inside the instrument. The symbols with messages are defined as follows: WARNING: Electrical Shock Hazard HAZARD: Strong oxidizer GENERAL WARNING/CAUTION: Read the accompanying message for s

Summary of the content on the page No. 19

Teledyne API Model 465L O Monitor Operation Manual 3 2.2.3. Other Type Certifications For additional certifications, please contact Customer Service: Toll-free 800-324-5190 Phone: Phone: 858-657-9800 Fax: 858-657-9816 Email: api-customerservice@teledyne.com 05509F DCN6409 17

Summary of the content on the page No. 20

Teledyne API Model 465L O Monitor Operation Manual 3 This page intentionally left blank. 18 05509F DCN6409


Alternative user manuals
# User manual Category Download
1 Teledyne 2002 User manual Marine Instruments 1
2 Teledyne 322 User manual Marine Instruments 0
3 Teledyne HCM-300 User manual Marine Instruments 0
4 Teledyne 5499 User manual Marine Instruments 0
5 Teledyne HPM 4/6 User manual Marine Instruments 13
6 Teledyne 450 User manual Marine Instruments 0
7 Teledyne 760 PLUS User manual Marine Instruments 0
8 Sony SSM-930 User manual Marine Instruments 3
9 Sony SSM-175A User manual Marine Instruments 0
10 Attwood 8M004689 User manual Marine Instruments 0
11 Attwood 99515-1 User manual Marine Instruments 0
12 Attwood 99510-1 User manual Marine Instruments 0
13 Attwood 99520-1 User manual Marine Instruments 0
14 Attwood 8M0044688 User manual Marine Instruments 0
15 Attwood 99540-1 User manual Marine Instruments 0