Sterling Power Products PDARRC user manual

User manual for the device Sterling Power Products PDARRC

Device: Sterling Power Products PDARRC
Category: Marine Instruments
Manufacturer: Sterling Power Products
Size: 4.57 MB
Added : 4/1/2014
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Sterling Power Products PDARRC. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Sterling Power Products PDARRC.

For your convenience

If looking through the Sterling Power Products PDARRC user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Sterling Power Products PDARRC on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Sterling Power Products PDARRC to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Sterling Power Products PDARRC User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Sterling Power Products PDARRC but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Sterling Power Products PDARRC. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

PDAR
WWW.STERLING-POWER.COM
PDARRC
WWW.STERLING-POWER-USA.COM
STERLING POWER PRODUCTS
ADVANCED ALTERNATOR REGULATOR
PRO-DIGITAL
Advanced charging technology
Installations Instructions & manual
English and German.
2 x temp sensors
Sterling Power Products
Advanced 4 step DIGITAL alt regulator
Pro Reg D
GREEN: High charge rate on
Alternator
YELLOW: Timer activated temp
GREEN: Float mode
Remote control optional extra
Battery
temp
ORANGE: Low voltage warning
D+
RED ONLY: High battery V trip
Ign

Summary of the content on the page No. 2

INSTALLATON MIT TRENNDIODE ODER RELAIS: INSTALLATON WITH SPLIT CHARGE DIODE OR RELAY: fan Temperature-Sensor l k f TERLING POWER PRODUCTS UNIVERSAL ADVANCED DIGITAL+ S EXTRA 4 STEP ALTERNATOR REGULATOR CONNECTIONS c GREEN: HIGH CHARGE RATE ON BLOCK ALT YELLOW: TIMER ACTIVATED TEMP GREEN: FLOAT MODE BATTERY TEMP ORANGE: LOW VOLTAGE WARNING D+ a RED ONLY : HIGH BATTERY V TRIP SWITCH e FLASHING RED: HIGH BATTERY TEMP BATTERY TYPE: GREEN: GEL/SEALED YELLOW: OPEN LEAD ACID ALL

Summary of the content on the page No. 3

INSTALLATON MIT TRENNDIODE ODER RELAIS: INSTALLATON WITH SPLIT CHARGE DIODE OR RELAY: fan Temperature-Sensor l k f TERLING POWER PRODUCTS UNIVERSAL ADVANCED DIGITAL+ S EXTRA 4 STEP ALTERNATOR REGULATOR CONNECTIONS c BLOCK GREEN: HIGH CHARGE RATE ON ALT YELLOW: TIMER ACTIVATED TEMP GREEN: FLOAT MODE BATTERY TEMP ORANGE: LOW VOLTAGE WARNING D+ a RED ONLY : HIGH BATTERY V TRIP SWITCH e FLASHING RED: HIGH BATTERY TEMP BATTERY TYPE: GREEN: GEL/SEALED YELLOW: OPEN LEAD ACID ALL

Summary of the content on the page No. 4

1 2 1 2 1 2 1 2 L.E.D. functions Fig.1 BATTERY TERLING POWER PRODUCTS Setup Up SELECTOR LED MAX. CHARGING ABSORBTION FLOATING UNIVERSAL ADVANCED DIGITAL+ S 4 STEP ALTERNATOR REGULATOR COLOUR VOLTAGE TIME VOLTAGE GREEN: HIGH CHARGE RATE ON a OPEN 14.8V / 20°C 1 - 3 HRS. 13.65V / 20°C YELLOW 1 LEAD ACID YELLOW: TIMER ACTIVATED b GEL- GREEN: FLOAT MODE 13.8V / 20°C c BATTERIES 14.4V / 20°C 10 - 12 HRS. GREEN 2 (EXIDE SPECIFICATION) ORANGE: LOW VOLTAGE WARNING d SEALED LEAD RED ONLY : HI

Summary of the content on the page No. 5

1 2 1 2 1 2 1 2 L.E.D. functions Fig.1 BATTERY TERLING POWER PRODUCTS Setup Up SELECTOR LED MAX. CHARGING ABSORBTION FLOATING UNIVERSAL ADVANCED DIGITAL+ S 4 STEP ALTERNATOR REGULATOR COLOUR VOLTAGE TIME VOLTAGE GREEN: HIGH CHARGE RATE ON a OPEN 14.8V / 20°C 1 - 3 HRS. 13.65V / 20°C YELLOW 1 LEAD ACID YELLOW: TIMER ACTIVATED b GEL- GREEN: FLOAT MODE 13.8V / 20°C c BATTERIES 14.4V / 20°C 10 - 12 HRS. GREEN 2 (EXIDE SPECIFICATION) ORANGE: LOW VOLTAGE WARNING d SEALED LEAD RED ONLY : HI

Summary of the content on the page No. 6

UNIVERSAL DIGITAL ADVANCED REGULATOR FITTING INSTRUCTIONS. This new unit is 1) Isolate the alternator from the batteries (to prevent any accidents with live cables) suitable for 12 and 24 volt operation, obviously to set this unit up as 24 volt on a 12 volt system, would be 2) Remove all the wires from the back of the alternator (note down on this sheet as you go through the catastrophic and all effort is made to ensure this does not happen. The unit comes preset to 12 volt operation

Summary of the content on the page No. 7

UNIVERSAL DIGITAL ADVANCED REGULATOR FITTING INSTRUCTIONS. This new unit is 1) Isolate the alternator from the batteries (to prevent any accidents with live cables) suitable for 12 and 24 volt operation, obviously to set this unit up as 24 volt on a 12 volt system, would be 2) Remove all the wires from the back of the alternator (note down on this sheet as you go through the catastrophic and all effort is made to ensure this does not happen. The unit comes preset to 12 volt operation

Summary of the content on the page No. 8

regulator. EQUALIZING TIME CYCLE: Remember to replace the old regulator back into the alternator do not leave it out. The software in the new Digital Regulator automatically calculates the equalizing time cycle every time the engine is started. This will range between 1-12 hours depending on the rise time between engine on and time to Set Up Advanced Regulator Before Installation reach 14 volts; this will be different every time the engine is started, and varies from battery type setting . T

Summary of the content on the page No. 9

regulator. EQUALIZING TIME CYCLE: Remember to replace the old regulator back into the alternator do not leave it out. The software in the new Digital Regulator automatically calculates the equalizing time cycle every time the engine is started. This will range between 1-12 hours depending on the rise time between engine on and time to Set Up Advanced Regulator Before Installation reach 14 volts; this will be different every time the engine is started, and varies from battery type setting . T

Summary of the content on the page No. 10

SETTINGS the internal pots are set up reference voltages for the new software control system, and not post may increase in temperature due to electrical resistance caused by bad connections, which could result in external voltage adjustment pots (as in the older, non digital models were). misleading temperature readings by the sensor. This would result in the Regulator shutdown with no fault with A word of warning, the most likely fault (assuming the Regulator is correctly connected) will be

Summary of the content on the page No. 11

SETTINGS the internal pots are set up reference voltages for the new software control system, and not post may increase in temperature due to electrical resistance caused by bad connections, which could result in external voltage adjustment pots (as in the older, non digital models were). misleading temperature readings by the sensor. This would result in the Regulator shutdown with no fault with A word of warning, the most likely fault (assuming the Regulator is correctly connected) will be

Summary of the content on the page No. 12

Battery Temperature sensor: see fig 3 part c Display Mode 2: Flashing L.E.D. This indicates that the temperature sensor has picked up the battery This sensor is the same type and configuration as the alternator temperature sensor, however, it should be placed temperature exceeding 50 degrees C. This usually means that the battery is defective and on it’s way to on the battery terminal on one of the batteries in the domestic battery bank, as this is the battery bank most likely boiling.

Summary of the content on the page No. 13

Battery Temperature sensor: see fig 3 part c Display Mode 2: Flashing L.E.D. This indicates that the temperature sensor has picked up the battery This sensor is the same type and configuration as the alternator temperature sensor, however, it should be placed temperature exceeding 50 degrees C. This usually means that the battery is defective and on it’s way to on the battery terminal on one of the batteries in the domestic battery bank, as this is the battery bank most likely boiling.

Summary of the content on the page No. 14

done after the alarm has gone off are pointless ) , the voltage at the domestic battery and the voltage at the engine battery . if you get results on a split diode system like, alt volts 16 volts, eng batt 15 volts , domestic battery 12 Helpful hints to find the Faults volts, then the domestic battery is not connected to the alternator, the most likley cause of this is failure of the split charger diode, or failure of the split charger relay. check the relay or diode . For a split charger r

Summary of the content on the page No. 15

done after the alarm has gone off are pointless ) , the voltage at the domestic battery and the voltage at the engine battery . if you get results on a split diode system like, alt volts 16 volts, eng batt 15 volts , domestic battery 12 Helpful hints to find the Faults volts, then the domestic battery is not connected to the alternator, the most likley cause of this is failure of the split charger diode, or failure of the split charger relay. check the relay or diode . For a split charger r

Summary of the content on the page No. 16

0 volts 0 volts 2 x wires fitted 14 volts 14 volts Positive field control alt neg neg A B by the installer as ( most common in American alts ) per the fitting instructions 2-12 volts and brought outside carbon 0 volts the alternator case brushes s B+ B+ main positive output copper slip rings main positive 0 volts 14 volts 0 volts 14 volts B - on rotor output neg A alternator case alternator rotor 0 volts 14 volts neg B+ alternator main positive output stator carbon brushes B+ main

Summary of the content on the page No. 17

0 volts 0 volts 2 x wires fitted 14 volts 14 volts Positive field control alt neg neg A B by the installer as ( most common in American alts ) per the fitting instructions 2-12 volts and brought outside carbon 0 volts the alternator case brushes s B+ B+ main positive output copper slip rings main positive 0 volts 14 volts 0 volts 14 volts B - on rotor output neg A alternator case alternator rotor 0 volts 14 volts neg B+ alternator main positive output stator carbon brushes B+ main

Summary of the content on the page No. 18

Explanation for Positive field control alternators Product to complement the advanced regulator Let us assume that the system over leaf has a regulator on the positive side of the rotor. then there is one Amp hr counter, 4 x volt meters, 4 x amp meters important fact, and that is because the regulator is between the brush and the positive then the other brush Can be used in negative and positive cables ( un like anyone else ) is connected directly to the negative. also the positive brush has

Summary of the content on the page No. 19

Explanation for Positive field control alternators Product to complement the advanced regulator Let us assume that the system over leaf has a regulator on the positive side of the rotor. then there is one Amp hr counter, 4 x volt meters, 4 x amp meters important fact, and that is because the regulator is between the brush and the positive then the other brush Can be used in negative and positive cables ( un like anyone else ) is connected directly to the negative. also the positive brush has

Summary of the content on the page No. 20

2) GEL-Batterien von EXIDE und VARTA = (wartungsfrei) können keine Gasung vertragen, d.h. eine STERLING PRO-DIGITAL HOCHLEISTUNGSREGLER Spannung über 14,4/28,8 Volt muss unbedingt vermieden werden. Da diese Batterien nur einen sehr geringen Ladestrom akzeptieren, beträgt die Ausgleichsladungszeit 12 - 24 Installationsanleitung Bitte unbedingt lesen! Stunden. (Bitte lesen Sie die Broschüre "EXIDE-GEL - Tipps und Kniffe für ein langes Batterieleben) Für Hitachi-Lichtmaschinen (Yanmar) bitt


Alternative user manuals
# User manual Category Download
1 Sterling Power Products PDAR User manual Marine Instruments 2
2 Sony SSM-930 User manual Marine Instruments 3
3 Sony SSM-175A User manual Marine Instruments 0
4 Attwood 8M004689 User manual Marine Instruments 0
5 Attwood 99515-1 User manual Marine Instruments 0
6 Attwood 99510-1 User manual Marine Instruments 0
7 Attwood 99520-1 User manual Marine Instruments 0
8 Attwood 8M0044688 User manual Marine Instruments 0
9 Attwood 99540-1 User manual Marine Instruments 0
10 Attwood 99530-1 User manual Marine Instruments 0
11 Atari LC-1 User manual Marine Instruments 0
12 Atari LM-1 User manual Marine Instruments 2
13 ATD Tools atd-5608 User manual Marine Instruments 1
14 Central Hydraulics 94143 User manual Marine Instruments 1
15 Central Pneumatic Air Compressor 95583 User manual Marine Instruments 0