Emerson Wireless pH/ORP Transmitter 6081-P user manual

User manual for the device Emerson Wireless pH/ORP Transmitter 6081-P

Device: Emerson Wireless pH/ORP Transmitter 6081-P
Category: Marine Instruments
Manufacturer: Emerson
Size: 2.26 MB
Added : 3/28/2014
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Emerson Wireless pH/ORP Transmitter 6081-P. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Emerson Wireless pH/ORP Transmitter 6081-P.

For your convenience

If looking through the Emerson Wireless pH/ORP Transmitter 6081-P user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Emerson Wireless pH/ORP Transmitter 6081-P on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Emerson Wireless pH/ORP Transmitter 6081-P to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Emerson Wireless pH/ORP Transmitter 6081-P User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Emerson Wireless pH/ORP Transmitter 6081-P but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Emerson Wireless pH/ORP Transmitter 6081-P. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

6081-P
Wireless pH/ORP Transmitter
Instruction Sheet 6081-P
LIQ_MAN_ABR_6081-P October 2013

Figure 1. 6081-P
Essential Instructions – Read this before proceeding
Rosemount Analytical designs, manufactures, and tests its products to meet many national and international standards.
Because these instruments are sophisticated technical products, you must properly install, use, and maintain them to
ensure they continue

Summary of the content on the page No. 2

6081-P Instruction Sheet October 2013 LIQ_MAN_ABR_6081-P Essential Instructions (continued) • Install your equipment as specified in the Installation Instructions of the appropriate Instruction Manual and per applicable local and national codes. Connect all products to the proper electrical and pressure sources. • To ensure proper performance, use qualified personnel to install, operate, update, program, and maintain the product. • When replacement parts are

Summary of the content on the page No. 3

Instruction Sheet 6081-P LIQ_MAN_ABR_6081-P October 2013 Quick Start Guide - 6081 Wireless pH Transmitter 1. Install the Power Module inside the rear enclosure. Follow the installation instructions on p.9 “Power Module Installation”. 2. Wire the pH or ORP sensor to the transmitter. Refer to the sensor instruction sheet for details. 3. Once the connections are secure and verified, install the Pow

Summary of the content on the page No. 4

6081-P Instruction Sheet October 2013 LIQ_MAN_ABR_6081-P Figure 2. Menu Tree for 6081 pH Wireless Transmitter 4

Summary of the content on the page No. 5

Instruction Sheet 6081-P LIQ_MAN_ABR_6081-P October 2013 Product Description When used with appropriate sensors, the 6081-P can measure pH or ORP (oxidation reduction potential) of a liquid and transmit data wirelessly with a radio transceiver which uses HART 7 communication protocol. The instrument has a local operator interface consisting of a keyboard and LCD display which can be used to observe process paramete

Summary of the content on the page No. 6

6081-P Instruction Sheet October 2013 LIQ_MAN_ABR_6081-P EEPROM Warning Sense Line Open Warning Factory Cal Warning Keyboard Warning Once a fault or warning is detected, the display will show a message describing the problem. Sensor Temperature Range: -10 to 150°C (PT100 and PT1000) Display: 2-line, 16 character display supports display of pH and mV units. Display shows temperature. Approvals: RFI/EMI: EN-61326 EN 301 489-1 V1.2 2002 EN 301 489-17: V1.4.1 2002

Summary of the content on the page No. 7

Instruction Sheet 6081-P LIQ_MAN_ABR_6081-P October 2013 pH Calibration Procedure – Auto Buffer Calibration 1. Obtain two buffer solutions. Ideally, the buffer values should bracket the range of pH values to be measured. 2. Remove the pH sensor from the process liquid. If the process and buffer temperatures are appreciably different place the sensor in a container of tap water at the buffer temperature. Do not start

Summary of the content on the page No. 8

6081-P Instruction Sheet October 2013 LIQ_MAN_ABR_6081-P Sensor Wiring Note For additional wiring information on this product, including sensor combinations not shown here, please refer to either our online wiring programs or the Manual DVD enclosed with each product. 1056, 1057, 56, 5081, 6081, 54e, and XMT : http://www3.emersonprocess.com/raihome/sp/liquid/wiring/XMT/ 1066 and sensors with SMART preamps: http://www2.emersonprocess.com/en-US/brands/rosemount

Summary of the content on the page No. 9

Instruction Sheet 6081-P LIQ_MAN_ABR_6081-P October 2013 Power Module Installation / Replacement The expected life of the power module (PN 701PBKKF) is a minimum of four years at reference conditions. This section describes the procedure for initial installation and replacement of the power module (PN 701PBKKF). The new power module should be stored in a safe place with a controlled environment until the 6081 is rea

Summary of the content on the page No. 10

6081-P Instruction Sheet October 2013 LIQ_MAN_ABR_6081-P Mounting Mounting on a Flat Surface Figure 4. Wall Mounting Installation for 6081. Use Pipe/Wall Mounting Bracket Kit, PN23820-00 Note: PN 23820-00 mounting bracket kit includes mounting hardware for pipe mounting only. Wall mounting hardware to be pro- vided by customer. Only use suitable fasteners and hardware to securely fasten the bracket and transmitter to the wall surface 10

Summary of the content on the page No. 11

Instruction Sheet 6081-P LIQ_MAN_ABR_6081-P October 2013 Pipe Mounting The pipe mounting kit (PN 23820-00/01) accommodates 1–½ in. pipe Figure 5. Pipe Mounting Installation for 6081. Use Pipe/Wall Mounting Bracket Kit, PN23820-00 11

Summary of the content on the page No. 12

6081-P Instruction Sheet October 2013 LIQ_MAN_ABR_6081-P Figure 6. FM IS Installation D 1700672 12 8 7 6 3 5 4 2 1 This document contains information proprietary to REVISION Rosemount Analytical, and is not to be made available to those who may compete with Rosemount Analytical. THIS DOCUMENT IS LTR ECO DESCRIPTION BY DATE CHECKED/APPROVED APPROVED MODELS CERTIFIED BY D LQD10215 SEE ECO CH 5-18-11 JP/ SP NOTES: UNLESS OTHERWISE SPECIFIED MARK

Summary of the content on the page No. 13

Instruction Sheet 6081-P LIQ_MAN_ABR_6081-P October 2013 Figure 7. CSA IS Installation D 1700673 13 8 7 6 5 3 4 2 1 This document contains information proprietary to REVISION Rosemount Analytical, and is not to be made available to those who may compete with Rosemount Analytical. THIS DOCUMENT IS LTR ECO DESCRIPTION BY DATE CHECKED/APPROVED APPROVED MODELS CERTIFIED BY D LQD10215 SEE ECO CH 5-18-11 J

Summary of the content on the page No. 14

6081-P Instruction Sheet October 2013 LIQ_MAN_ABR_6081-P Figure 8. ATEX IS Installation D 1700674 14 8 7 6 3 5 4 2 1 This document contains information proprietary to REVISION Rosemount Analytical, and is not to be made available to those who may compete with Rosemount Analytical. LTR ECO DESCRIPTION BY DATE CHECKED/APPROVED THIS DOCUMENT IS APPROVED MODELS CERTIFIED BY NOTES: UNLESS OTHERWISE SPECIFIED 6081-P-73-XXX REV 1. PCB MATERIAL

Summary of the content on the page No. 15

Instruction Sheet 6081-P LIQ_MAN_ABR_6081-P October 2013 15

Summary of the content on the page No. 16

6081-P Instruction Sheet October 2013 LIQ_MAN_ABR_6081-P facebook.com/EmersonRosemountAnalytical AnalyticExpert.com Credit Cards for U.S. Purchases Only. twitter.com/RAIhome youtube.com/user/RosemountAnalytical ©2013 Rosemount Analytical, Inc. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. Brand name is a mark of one of the Emerson Process Management family of companies. All other marks are the property of their


Alternative user manuals
# User manual Category Download
1 Emerson Digital Controller Valves 788 DVC User manual Marine Instruments 31
2 Emerson Four-electrode Conductivity Sensor 410VP User manual Marine Instruments 0
3 Emerson FCL with 1050 Analyzer 1056 User manual Marine Instruments 149
4 Emerson Four-electrode Conductivity Sensor PN 51A-410VP User manual Marine Instruments 0
5 Emerson ENDURANCE Conductivity Sensor 404 User manual Marine Instruments 1
6 Emerson ENDURANCE Conductivity Sensor PN 51A-404 User manual Marine Instruments 1
7 Emerson FCL with 1050 Analyzer PN 51-FCL-1056 User manual Marine Instruments 12
8 Emerson Mass Flow Transmitter 3095 User manual Marine Instruments 34
9 Emerson Multiport Flow Selector I-0168 User manual Marine Instruments 6
10 Emerson pH/ORP Analyzer/Controller 54e User manual Marine Instruments 3
11 Emerson pH/ORP Analyzer/Controller PN 51A-54epH User manual Marine Instruments 3
12 Emerson Mass Flow Transmitter 00825-0100-4716 User manual Marine Instruments 2
13 Emerson Rosemount Pressure Transmitter 3051S User manual Marine Instruments 58
14 Emerson pH/ORP Analyzer/Controller 54e pH User manual Marine Instruments 18
15 Emerson Tank Contents Transmitter MAS 2600 User manual Marine Instruments 115
16 Sony SSM-930 User manual Marine Instruments 3
17 Sony SSM-175A User manual Marine Instruments 0
18 Attwood 8M004689 User manual Marine Instruments 0
19 Attwood 99515-1 User manual Marine Instruments 0
20 Attwood 99510-1 User manual Marine Instruments 0