Our goal is to provide you with a quick access to the content of the user manual for Fluke RUSKA 2470. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Fluke RUSKA 2470.

For your convenience

If looking through the Fluke RUSKA 2470 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Fluke RUSKA 2470 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Fluke RUSKA 2470 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Fluke RUSKA 2470 User manual - Online PDF
Advertisement
« Page 1 of 78 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Fluke RUSKA 2470 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Fluke RUSKA 2470. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


RUSKA 2470
Gas Lubricated Piston Pressure Gauge



Users Manual

PN 3974971
December 2010
© 2010 Fluke Corporation. All rights reserved. Printed in USA. Specifications are subject to change without notice.
All product names are trademarks of their respective companies.

Summary of the content on the page No. 2

LIMITED WARRANTY AND LIMITATION OF LIABILITY Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is one year and begins on the date of shipment. Parts, product repairs, and services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries, or to any product which, in Fluke's opinion, ha

Summary of the content on the page No. 3

Table of Contents Chapter Title Page 1 Introduction......................................................................................... 1-1 How to Contact Fluke ........................................................................................ 1-1 Safety Information ............................................................................................. 1-1 Compressed Gas ............................................................................................ 1-1 Lu

Summary of the content on the page No. 4

RUSKA 2470 Users Manual Precautions......................................................................................................... 5-1 General............................................................................................................... 5-2 Low Range Piston Assembly............................................................................. 5-2 Mid Range Piston Assembly.............................................................................. 5-7 High Range

Summary of the content on the page No. 5

List of Tables Table Title Page 1-1. Symbols.................................................................................................................. 1-2 iii

Summary of the content on the page No. 6

RUSKA 2470 Users Manual iv

Summary of the content on the page No. 7

List of Figures Figure Title Page 2-1. Simple Cylinder..................................................................................................... 2-1 2-2. Re-Entrant Cylinder............................................................................................... 2-1 2-3. Controlled Clearance Cylinder............................................................................... 2-2 2-4. Reference Plane Determination......................................................

Summary of the content on the page No. 8

RUSKA 2470 Users Manual 6-11. Preparing the Kim Wipe for Cleaning the High Range Cylinder - Step 2 ............. 6-11 6-12. Preparing the Kim Wipe for Cleaning the High Range Cylinder - Step 3 ............. 6-11 6-13. Cleaning the High Range Cylinder ........................................................................ 6-11 6-14. Drying the High Range Cylinder ........................................................................... 6-12 vi

Summary of the content on the page No. 9

Chapter 1 Introduction How to Contact Fluke To order accessories, receive operating assistance, or get the location of the nearest Fluke distributor or Service Center, call: • Technical Support USA: 1-800-99-FLUKE (1-800-993-5853) • Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853) • Canada: 1-800-36-FLUKE (1-800-363-5853) • Europe: +31-402-675-200 • China: +86-400-810-3435 • Japan: +81-3-3434-0181 • Singapore: +65-738-5655 • Anywhere in the world: +1-425-446-5500 Or, visit Flu

Summary of the content on the page No. 10

RUSKA 2470 Users Manual Lubricants and Seals DO NOT use hydrocarbon lubricants in this device, use only approved lubricants. Always use replacement parts specified by Fluke. For more information regarding common replacement parts and recommended lubricants, see Appendix B. Oxygen Compatibility This Instrument has been designed with components that will not introduce hydrocarbons into the calibration process. The O-rings and lubricating grease supplied with the instrument must not

Summary of the content on the page No. 11

Introduction Specifications 1 Specifications Low Range Piston Pressure Range (Model 2465) 1.4 to 172 kPa (0.2 to 25 psi) psi gauge Pressure Range (Model 2468) 1.4 to 345 kPa (0.2 to 50 psi) psi gauge (1,2) Pressure Uncertainty Rating 0.0010% (10 ppm) or 0.07 Pa (1.0E-05 psi), whichever is greater Uncertainty Threshold 7 kPa (1 psi) Resolution 1 ppm or 1 mg, whichever is greater Precision (Typical Type A Unc.) 3 ppm (3) Long Term Stability 3 ppm per year Piston/Cylinder Material 44

Summary of the content on the page No. 12

RUSKA 2470 Users Manual Temperature Range Operating 18 ºC to 28 ºC Storage -40 ºC to 70 ºC when thermometer and low range piston & Cylinder are stored separately from each other. Humidity Range Operating 20% to 75% noncondensing Storage 0% to 90% noncondensing Pressure Medium Clean dry gas, Nitrogen or equivalent, regulated to a pressure Compatible with each particular Piston/cylinder assembly. Dew Point of less than or equal to -60 ºF Pressure Maximum Working Press

Summary of the content on the page No. 13

Chapter 2 General Piston Pressure Gauge Considerations Types of Piston Pressure Gauges The piston pressure gauge is sometimes regarded as an absolute instrument because of the principle by which it measures pressure. An absolute instrument is defined here as one capable of measuring a quantity in the fundamental units of mass, length, time, etc. It may be suggested that only certain types of piston pressure gauges qualify in this category. Figures 2-1, 2-2, and 2-3 illustrate the three

Summary of the content on the page No. 14

RUSKA 2470 Users Manual SECONDARY PRESSURE PRESSURE IN glg45.eps Figure 2-3. Controlled Clearance Cylinder When the simple cylinder of 2-1 is subjected to an increase in pressure, the fluid, exerting a relatively large total force normal to the surface of confinement, expands the cylinder and thus increases its area. A pressure-drop appears across the cylinder wall near point A, resulting in an elastic dilation of the cylinder bore. It can be shown that the effective area of the piston

Summary of the content on the page No. 15

General Piston Pressure Gauge Considerations Calculations 2 Measurement of pressure with the piston pressure gauge is subject to uncertainties resulting from effects other than those of elastic distortion. But, it was appropriate that the subject of elastic distortion be discussed first, since this characteristic is largely responsible for the various designs that have been developed. Measurement processes proposed for high accuracy are disturbed by limitations in the performance of the

Summary of the content on the page No. 16

RUSKA 2470 Users Manual Elastic Distortion of the Cylinder As the pressure is increased within a piston pressure gauge, the resulting stress produces a temporary and reversible deformation of the cylinder. The net effect is a change in the effective area of the piston-cylinder combination. If the change in the area is a linear function of the applied pressure, the relationship may be described by the equation: 2 A = A() 1+ b P + b P e 0 1 2 Where: P is the nominal pressure A is the e

Summary of the content on the page No. 17

General Piston Pressure Gauge Considerations Measurement of Pressure with the Piston Pressure Gauge 2 Although the trend is swinging toward the use of true mass in favor of apparent mass, there is a small advantage in the use of the latter. When making calculations for air buoyancy from values of apparent mass, it is unnecessary to know the density of the mass. If objects of different densities are included in the calculation, it is not necessary to distinguish the difference in the calc

Summary of the content on the page No. 18

RUSKA 2470 Users Manual It is common practice to associate this position directly with the piston as the datum to which all measurements made with the piston are referenced. It is called the reference plane of measurement, and its location is determined from the dimensions of the piston. If the submerged portion of the piston is of uniform cross section, the reference plane is found to lie conveniently at the lower extremity as shown in 2-4. If, however, the portion of the piston submerg

Summary of the content on the page No. 19

General Piston Pressure Gauge Considerations Measurement of Pressure with the Piston Pressure Gauge 2 glg03.bmp Figure 2-5. Head Correction Measurement P =() P − P *h* g H m AIR Where: h is the vertical distance between the reference plane of the Standard and the reference plane of the DUT (Device Under Test) ρ is the density of the air air ρ is the density of the test media m g is the acceleration due to local gravity L1 is the vertical distance from the mass loading location to

Summary of the content on the page No. 20

RUSKA 2470 Users Manual For good work, a piston pressure gauge should be provided with an index mark for associating the reference of the piston with other planes of interest within a system. The design of this index will vary with the design and manufacture of the instrument, it may be in the form or an index rod with scribed lines on it, an index groove on the column of the instrument, or, other type of fixed indicator. Not only does the mark serve to establish fixed values of pressure


Alternative user manuals
# User manual Category Download
1 Fluke 700G User manual Marine Instruments 34
2 Sony SSM-930 User manual Marine Instruments 3
3 Sony SSM-175A User manual Marine Instruments 0
4 Attwood 8M004689 User manual Marine Instruments 0
5 Attwood 99515-1 User manual Marine Instruments 0
6 Attwood 99510-1 User manual Marine Instruments 0
7 Attwood 99520-1 User manual Marine Instruments 0
8 Attwood 8M0044688 User manual Marine Instruments 0
9 Attwood 99540-1 User manual Marine Instruments 0
10 Attwood 99530-1 User manual Marine Instruments 0
11 Atari LC-1 User manual Marine Instruments 0
12 Atari LM-1 User manual Marine Instruments 2
13 ATD Tools atd-5608 User manual Marine Instruments 1
14 Central Hydraulics 94143 User manual Marine Instruments 1
15 Central Pneumatic Air Compressor 95583 User manual Marine Instruments 0