Emerson ENDURANCE Conductivity Sensor PN 51A-404 user manual

User manual for the device Emerson ENDURANCE Conductivity Sensor PN 51A-404

Device: Emerson ENDURANCE Conductivity Sensor PN 51A-404
Category: Marine Instruments
Manufacturer: Emerson
Size: 0.29 MB
Added : 3/28/2014
Number of pages: 8
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Emerson ENDURANCE Conductivity Sensor PN 51A-404. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Emerson ENDURANCE Conductivity Sensor PN 51A-404.

For your convenience

If looking through the Emerson ENDURANCE Conductivity Sensor PN 51A-404 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Emerson ENDURANCE Conductivity Sensor PN 51A-404 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Emerson ENDURANCE Conductivity Sensor PN 51A-404 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Emerson ENDURANCE Conductivity Sensor PN 51A-404 User manual - Online PDF
Advertisement
« Page 1 of 8 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Emerson ENDURANCE Conductivity Sensor PN 51A-404 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Emerson ENDURANCE Conductivity Sensor PN 51A-404. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Instruction Sheet
PN 51A-404/rev.M
December 2010
Model 404

ENDURANCE Conductivity Sensor
For additional information, please visit our website
at www.emersonprocess.com/raihome/liquid/.
CAUTION
SENSOR/PROCESS WARNING
WARNING
APPLICATION COMPATIBILITY
Before removing the sensor, be absolutely certain
The wetted sensor materials may not be compatible
that the process pressure is reduced to 0 psig and
with process com position and operating conditions.
the process temperature is lowered to a safe

Summary of the content on the page No. 2

MODEL 404 WIRING WIRING WIRE COLOR AND CONNECTIONS IN SENSOR COLOR FUNCTION Gray Connects to outer electrode Clear Coaxial shield for gray wire Orange Connects to inner electrode Clear Coaxial shield for orange wire Red RTD in White with red stripe RTD RTD sense White RTD return Clear Shield for all RTD lead wires WIRING DIAGRAMS FIGURE 2. Model 54eC Wiring FIGURE 3. Model 56 and 1056 Wiring TB2 TB1 RTN WHITE RCV B SENSE WHITE/RED RCV A RTD IN RED CLEAR RSHLD SHLD DRVB CLEAR GRAY ORANGE DRVA

Summary of the content on the page No. 3

MODEL 404 INSTALLATION FIGURE 5. Model Xmt-C-10 Wiring (Panel) FIGURE 6. Model Xmt-C-11 Wiring (Pipe or Wall) FIGURE 7. Model 5081-C Wiring FIGURE 8. Model 6081-C Wiring WIRING THROUGH A JUNCTION BOX If wiring connections are made through a remote junction box (PN 23550-00), wire point-to-point. Use cable 23747-00 (factory-terminated) or 9200275 (no terminations). 3

Summary of the content on the page No. 4

MODEL 404 WIRING CLEANING THE SENSOR The 404-17 (stainless steel body) sensor can be taken apart for cleaning. However, in some cases, disassembling and reassembling the sensor can cause the cell constant to change as much as 1%. For maximum accuracy, the cell con- stant should be rechecked after the sensor has been reassembled. The 400-16 (PVC body) sensor cannot be taken apart. Use a warm detergent solution and a soft brush or pipe cleaner to remove oil and scale. Isopropyl alcohol (rubbing al

Summary of the content on the page No. 5

MODEL 404 WIRING TROUBLESHOOTING PROBLEM PROBABLE CAUSE SOLUTION Off-scale reading Wiring is wrong. Verify wiring. Temperature element is open or shorted. Check temperature element for open or short circuits. See Figure 9. Sensor is not in process stream. Be sure sensor is completely submerged in process stream. Variopol cable is not properly seated. Loosen connector and reseat. Sensor has failed. Perform isolation checks. See Figure 10. Noisy reading Sensor is improperly installed in process

Summary of the content on the page No. 6

NOTES 6

Summary of the content on the page No. 7

NOTES 7

Summary of the content on the page No. 8

The right people, the right answers, ON-LINE ORDERING NOW AVAILABLE ON OUR WEB SITE right now. http://www.raihome.com Specifications subject to change without notice. Credit Cards for U.S. Purchases Only. Emerson Process Management 2400 Barranca Parkway Irvine, CA 92606 USA Tel: (949) 757-8500 Fax: (949) 474-7250 http://www.raihome.com © Rosemount Analytical Inc. 2010 8


Alternative user manuals
# User manual Category Download
1 Emerson Digital Controller Valves 788 DVC User manual Marine Instruments 31
2 Emerson Four-electrode Conductivity Sensor 410VP User manual Marine Instruments 0
3 Emerson FCL with 1050 Analyzer 1056 User manual Marine Instruments 149
4 Emerson Four-electrode Conductivity Sensor PN 51A-410VP User manual Marine Instruments 0
5 Emerson ENDURANCE Conductivity Sensor 404 User manual Marine Instruments 1
6 Emerson FCL with 1050 Analyzer PN 51-FCL-1056 User manual Marine Instruments 12
7 Emerson Mass Flow Transmitter 3095 User manual Marine Instruments 34
8 Emerson Multiport Flow Selector I-0168 User manual Marine Instruments 6
9 Emerson pH/ORP Analyzer/Controller 54e User manual Marine Instruments 3
10 Emerson pH/ORP Analyzer/Controller PN 51A-54epH User manual Marine Instruments 3
11 Emerson Mass Flow Transmitter 00825-0100-4716 User manual Marine Instruments 2
12 Emerson Rosemount Pressure Transmitter 3051S User manual Marine Instruments 58
13 Emerson pH/ORP Analyzer/Controller 54e pH User manual Marine Instruments 18
14 Emerson Tank Contents Transmitter MAS 2600 User manual Marine Instruments 115
15 Emerson turbine meter 1500 User manual Marine Instruments 8
16 Sony SSM-930 User manual Marine Instruments 3
17 Sony SSM-175A User manual Marine Instruments 0
18 Attwood 8M004689 User manual Marine Instruments 0
19 Attwood 99515-1 User manual Marine Instruments 0
20 Attwood 99510-1 User manual Marine Instruments 0