Curtis 2200R user manual

User manual for the device Curtis 2200R

Device: Curtis 2200R
Category: Marine Instruments
Manufacturer: Curtis
Size: 0.05 MB
Added : 3/28/2014
Number of pages: 18
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Curtis 2200R. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Curtis 2200R.

For your convenience

If looking through the Curtis 2200R user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Curtis 2200R on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Curtis 2200R to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Curtis 2200R User manual - Online PDF
Advertisement
« Page 1 of 18 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Curtis 2200R but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Curtis 2200R. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

MODEL 2100R&
2200R Engine Gages
Read Instructions Carefully !
!

Summary of the content on the page No. 2

Safety Instructions ! This instrument was manufactured and tested according to the applicable technical standards. It complies with all the safety regulations as shipped from the factory. Installation and startup must be performed by skilled personnel. Failure to install and operate the unit in accordance with these instructions may result in damage or injury. If safe operation of the instrument can no longer be ensured, stop and secure it against accidental operation. If instrument failure or m

Summary of the content on the page No. 3

TABLE OF CONTENTS Page 1. Safety Instructions 2 ! 2. Model Encodement 3 3. Technical Specifications 3.1 Electrical 5 3.2 Mechanical 8 3.3 Environmental 9 4. Installation 11 5. Troubleshooting 14 6. Maintenance 15 !

Summary of the content on the page No. 4

2. MODEL ENCODEMENT (for 2100R/2200R series) ! 2111RXX-YYYY ZZ Model Numbers 2111 Temperature 2112 Fuel 2113 Pressure 2114 Voltage 2211 Temperature/Hour 2212 Fuel/Hour 2213 Pressure/Hour 2214 Voltage/Hour 3

Summary of the content on the page No. 5

! R = case (round) XX = voltage (DC voltages only) YYYY = sequential number code describes gage’s factory programming ZZ = artwork code (OO = Curtis) 4

Summary of the content on the page No. 6

3. TECHNICAL SPECIFICATIONS ! 3.1 Electrical Operating Voltage Model Series 2100R and 2200R are available in either 12VDC or 24VDC (negative ground systems only) Operating Voltages (Models 2111R, 2112R, 2113R and 2211R, 2212R, 2213R) Model Minimum Nominal Maximum 12V 9.0 12.0 16.0 24V 18.0 24.0 32.0 (Models 2114R and 2214R) Model Minimum Nominal Maximum 12V 8.0 12.0 18.0 24V 16.0 24.0 36.0 Accuracy Maximum indicator error is less than ±3.5% of full scale 5

Summary of the content on the page No. 7

Operating Current Total system current is a function of the voltage, ! sender type, display mode, and the gage’s factory programming. Typical operating currents (not including the current to drive the sender) vary from 16-55 mA, for 12V models, depending on model number. For 24V models, typical operating currents (not including the current to drive the sender) vary from 18-45 mA, depending on model number. Variable Parameters The following parameters are set in the factory as part of the gage’s

Summary of the content on the page No. 8

Output signal trigger point (lower) First LED Second LED ! Output signal trigger point (upper) Ninth LED Tenth LED Output signal format—(upper and lower independently set) 0-5 V 5-0 V* LED flashing mode (lower) No flashing First LED flashes alone First LED or second flashes alone Both first & second flash out of phase* LED flashing mode (upper) No flashing Tenth LED flashes alone Both tenth & ninth flash in phase Both tenth & ninth flash out of phase* *indicates standard setting 7

Summary of the content on the page No. 9

Damping and Hysteresis Transducer power modulation (XPM) ! Used to reduce current in sender circuit Output signal format Outputs are capable of sinking or sourcing up to 1mA, maximum (50µ A maximum is standard) The 5V-0 output signal format is fully compatible with the Curtis Model 1178 relay module. 3.2 Mechanical Terminals (Spade) 6 ANSI/NEMA 0.25 inch male fast-ons Dimensions Bezel diameter 58.8 mm, maximum Case diameter 51.5 mm, maximum Depth 45.0 mm, maximum

Summary of the content on the page No. 10

Bezel Material Aluminum, black anodized Hardware U clamp (1) (Individually boxed 4 mm lock washers (2) units) Female 1/4 inch fast-on connectors (up to 6) 4 mm knurled thumbnuts (2) Hardware U clamp (1) (OEM bulk packed) 4 mm lock washers (2) 4 mm hex nuts (2) ! 3.3 Environmental Temperature Operating -40C to +85C Storage -50C to +90C Shock Meets SAE J 1378 March 83. Amplitude 44-55g, half sine, 9-13 msec duration. 9

Summary of the content on the page No. 11

Vibration Meets SAE J 1378 March 83. ! Double amplitude of 1.53 mm with frequency sweep from 10-80-10 Hz (20 g max) at intervals of 1 minute. Humidity 95% RH (non-condensing) at +38C Water/dust immunity Face IP63 Rear IP50 Salt spray (fog) ASTM B 117-73 as per SAE J1810, section 4.7.1.2 10

Summary of the content on the page No. 12

! 4.INSTALLATION Terminal Assignment for Models 2111R, 2112R, 2113R 1 Sender in 2Battery + 3Ground 4 Sender low (optional: for use with two wire senders) 5 Output signal (upper) 6 Output signal (lower) 11

Summary of the content on the page No. 13

Terminal Assignment for Model 2114R ! 1 Not Connected ** 2Battery + 3Ground 4 Not Connected** 5 Output signal (upper) 6 Output signal (lower) Terminal Assignments for Models 2211R, 2212R, 2213R 1 Sender in 2Battery + 3Ground 4 Hourmeter enable* 5 Output signal (upper) 6 Output signal (lower) 12

Summary of the content on the page No. 14

Terminal Assignments for Model 2214R ! 1 Not connected*** 2Battery + 3Ground 4 Hourmeter enable*** 5 Output signal (upper) 6 Output signal (lower) * Options terminal can be factory programmed to function as hourmeter reset or sender low (for use with two wire senders) **Options terminal-can be factory programmed to measure a separate variable voltage supply. ***Options terminals-can be factory programmed to measure a separate variable voltage supply. Hourmeter enable terminal could be fa

Summary of the content on the page No. 15

5. TROUBLESHOOTING The following checklist should help you to trou- ! bleshoot any problems with the instrument. Turning the instrument off and then on again after about 10 seconds may solve the problem in the simplest cases. Make sure to observe the safety instructions in Section 1. Problem Possible Cause No display Voltage on Battery + terminal insufficient Display is not accurate Check sender installation.Teflon tape, some lubricants and anti-sieze compounds may prevent proper grounding of

Summary of the content on the page No. 16

6. MAINTENANCE ! Curtis 2100R & 2200R Series Engine Gages are not serviceable in the field. Units returned to the factory within the warranty period will be replaced without charge. 16

Summary of the content on the page No. 17

Guarantee - These Curtis Instruments’ products are guaran- teed against defects in workmanship and material for a period of three years, or as defined in the individual product literature, from date of shipment from our factory, when applied in a prop- er application within specified ratings. This guarantee is limited to repair or replacement F.O.B. our factory. There is no further warranty or implied representation, guarantee, promise or agreement as to any Curtis Instruments product and/or com

Summary of the content on the page No. 18

CURTIS INSTRUMENTS, INC. 200 Kisco Avenue, Mt. Kisco, NY 10549 Tel. (914) 666-2971 • FAX (914) 666-2188 53018 REV A 10/97


Alternative user manuals
# User manual Category Download
1 Curtis 2100R User manual Marine Instruments 1
2 Sony SSM-930 User manual Marine Instruments 3
3 Sony SSM-175A User manual Marine Instruments 0
4 Attwood 8M004689 User manual Marine Instruments 0
5 Attwood 99515-1 User manual Marine Instruments 0
6 Attwood 99510-1 User manual Marine Instruments 0
7 Attwood 99520-1 User manual Marine Instruments 0
8 Attwood 8M0044688 User manual Marine Instruments 0
9 Attwood 99540-1 User manual Marine Instruments 0
10 Attwood 99530-1 User manual Marine Instruments 0
11 Atari LC-1 User manual Marine Instruments 0
12 Atari LM-1 User manual Marine Instruments 2
13 ATD Tools atd-5608 User manual Marine Instruments 1
14 Central Hydraulics 94143 User manual Marine Instruments 1
15 Central Pneumatic Air Compressor 95583 User manual Marine Instruments 0