Summary of the content on the page No. 1
SAMSUNG DVM-Pro 2008 User Guide
SAMSUNG DVM-Pro 2008
User’s Manual (Sales mode)
English Version
2008 . 02 . 28
1
Summary of the content on the page No. 2
SAMSUNG DVM-Pro 2008 User Guide Contents 1. User’s manual for Sales mode of DVM Pro 1-1. Architecture of sales mode 2. Top Down menu 2-1. File 2-2. View 2-3. Setup 2-4. Help 3. Project 3-1. Project Information 3-1-1. Project name 3-1-2. Country 3-1-3. Customer Information 3-1-4. Designer Information 3-2. Setup Space 3-3. Workspace management 4. Indoor unit 4-1. Workspace 4-2. Add Indoor 4-3. Edit Indoor
Summary of the content on the page No. 3
SAMSUNG DVM-Pro 2008 User Guide 6-1. Workspace 6-2. Piping 6-2-1. Select Indoor 6-2-2. Select Piping connection tools 6-2-3. Basic Pipe, Standard Pipe, Manual Pipe 6-2-4. Draw Piping manually 6-2-5. View Diagram 6-2-6. Check System 7. Wiring 8. Control System 9. Report 9-1. Insert Logo 9-2. Reporting Information 9-3. Workspace to include in Report 9-4. Currency 9-4. Takes Report off 3
Summary of the content on the page No. 4
SAMSUNG DVM-Pro 2008 User Guide 1. User’s manual for Sales mode of DVM Pro 1-1. Architecture of sales mode -. The sales mode of DVM Pro is an application software to help business of System A/C. It’s configured with Project, Indoor, Outdoor, Piping, Wiring, Control System and Report. And can’t move to next step if no completion of current step because these works would be executed, step by step. 2. Top Down menu : This menus are shown on upper-end the screen and configured with Fil
Summary of the content on the page No. 5
SAMSUNG DVM-Pro 2008 User Guide -. Conversion 5
Summary of the content on the page No. 6
SAMSUNG DVM-Pro 2008 User Guide -. Languages 2-4. Help : Show the version information of DVM program and user can move to the related web page directly. 6
Summary of the content on the page No. 7
SAMSUNG DVM-Pro 2008 User Guide 3. Project : Set Project registration and Workspace. 3-1. Project Information : . User can register the project when start new project. User must fill out all blanks of project registration fields if new project. . Show the related information if it’s current project. 3-1-1. Project name : Enter project name to be registered. 3-1-2. Country : Select country. 3-1-3. Customer information : Enter customer information. 3-1
Summary of the content on the page No. 8
SAMSUNG DVM-Pro 2008 User Guide Bldg Area Floor Area -. Setup building a. Add Building : add the building. -. New building is added if enter building code and name after press [add building]. * Can’t duplicate the code name and the code are configured with alphabet and Arabic. b. Make Floor : Form the floor per each building. -. Select the building to make floor. -. Enter the number of floor
Summary of the content on the page No. 9
SAMSUNG DVM-Pro 2008 User Guide c. Add / delete floor : Can create or delete additional floor after make the floor. . -. New floor is added if enter building code and name after press [add floor]. * Can’t duplicate the code name and the code are configured with alphabet and Arabic. d. Edit Floor height : Edit current floor height. -. Edit the floor height after select the relevant position of floor under title of floor height. -. Can edit
Summary of the content on the page No. 10
SAMSUNG DVM-Pro 2008 User Guide 4. Indoor unit : User can select, add and delete Indoor unit. And can select option per each Indoor unit. 4-1 Workspace : It shows the detailed information about workspace that displays, and can change, and using workspace that is using present in workspace selection window. 4-2. Add Indoor : Can add Indoor unit that wish to use. a. Indoor unit : Select name, type, Model Name. * If cancel check indication in front o
Summary of the content on the page No. 11
SAMSUNG DVM-Pro 2008 User Guide after press [edit] button. 4-5. [View Indoor unit] window : It shows Indoor to be used. -. Display Indoor unit name, Model Name, cooling temperature, cooling capacity, Cooling (kW), heating temperature, heating capacity, heating (kW), Indoor unit type, floor, K2 and etc. -. After do [add Indoor unit], it shows the yellow indication in front of the relevant Indoor unit in case of it's selected manually by Indoor unit correction. -. K 2 is un
Summary of the content on the page No. 12
SAMSUNG DVM-Pro 2008 User Guide 5. Outdoor unit 5-1. Workspace : It shows the detailed information about workspace that displays, and can change, and using workspace that is using present in workspace selection window. -. Choose workspace that wish to work. 5-2. Add Outdoor : Add Outdoor unit to connect the unconnected Indoor unit with Outdoor unit. -. Press confirmation after input the name, combination rate, floor, cooling temperature and heating temperature after press [add]
Summary of the content on the page No. 13
SAMSUNG DVM-Pro 2008 User Guide -. When add Outdoor unit, Outdoor unit of smallest capacity is added by workspace base. The capacity fluctuates automatically according to modification of the connected Indoor unit. -. Connect Indoor unit that adds to Outdoor unit in existing, or unconnects after add Outdoor unit pressing [add] button in case of there is the unconnected Outdoor unit. Method that connect Indoor unit to addon one or member with name of Outdoor unit to connect tut that pr
Summary of the content on the page No. 14
SAMSUNG DVM-Pro 2008 User Guide -. If there is “ ” ICON In front of Outdoor unit ”, user must add more Indoor than combination rate. -. How to do if ondoor unit were connected with more Indoors than the combination rate ? . Add Outdoor unit. . Move Indoor unit toward Outdoor which was added. . User must adjust the combination rate. 5-3. Edit Outdoor -. Edit outdoor after press "Edit" button after select Outdoor unit to be edited if need to edit Outdoor unit. 14
Summary of the content on the page No. 15
SAMSUNG DVM-Pro 2008 User Guide 5-4. Delete Outdoor unit -. When delete Outdoor unit, it shows message that "do you want to delete the selected “Outdoor xx?" if press “delete” button after select Outdoor unit to delete. It would be deleted if presses “yes”. Now Indoor units had connected with the deleted Outdoor unit would be moved to “unconnected Indoor unit” window on right-side lower column. 5-5. Copy Indoor -. Selects Outdoor unit that wish to co
Summary of the content on the page No. 16
SAMSUNG DVM-Pro 2008 User Guide 5-6. Compensate Outdoor -. Outdoor Compensation can operate after refrigerant piping is linked, and it's not activated in case of there is more than combination rate. -. Select Outdoor unit to need [Compensate Outdoor]. -. Press '[Compensate Outdoor] button. -. Select the area to need [compensation option] among compensation and heating compensation selects necessary segment. -. Choose installation position of Indoor unit and Ou
Summary of the content on the page No. 17
SAMSUNG DVM-Pro 2008 User Guide 5-7. Window of Outdoor Information -. The detailed information regarding Outdoor unit and Indoor unit on the right-end screen is seen automatically. Impossible to edit the detailed information. 17
Summary of the content on the page No. 18
SAMSUNG DVM-Pro 2008 User Guide 5-8. Indoor units not yet attached -. In case of there is unconnected Indoor unit, piping connection mode is not activated. -. Delete it by delete command after select no needful indoor among unconnected Indoor unit 6. Piping 6-1. Workspace : It shows the details information about workspace that displays and can change, and uses workspace that is using present in workspace selection window. -. Choose workspace that wish to work.
Summary of the content on the page No. 19
SAMSUNG DVM-Pro 2008 User Guide 6-2-4. Draw Manual Pipe : User can edit the Piping at free. -. If check manual Pipe], piping connection tool is activated. -. Remove Net : It shows [Remove Net] if press a right mouse on the Ref Joint that is blue triangle part of piping system diagram or on the Indoor unit. If select [Remove Net], the pipe at lower of the selected Ref Joint will be disappeared and next Indoor of Ref Joint will be moved to No-linked Indoor.
Summary of the content on the page No. 20
SAMSUNG DVM-Pro 2008 User Guide -. After [Remove Net] -. If remove net, square empty box appears and inserts the connection tool in the box and can connect user free piping. -. After insert piping connection tool -. It's inserted if put in empty quadrilateral attracting Indoor unit that unconnect after link the connection tool. -. Image that Indoor units are inserted 20