Sub-Zero 424/O user manual

User manual for the device Sub-Zero 424/O

Device: Sub-Zero 424/O
Category: Beverage Dispenser
Manufacturer: Sub-Zero
Size: 0.62 MB
Added : 4/9/2014
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Sub-Zero 424/O. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Sub-Zero 424/O.

For your convenience

If looking through the Sub-Zero 424/O user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Sub-Zero 424/O on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Sub-Zero 424/O to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Sub-Zero 424/O User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Sub-Zero 424/O but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Sub-Zero 424/O. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

W INE S TORAGE
INSTALLATION INSTRUCTIONS

Summary of the content on the page No. 2

SUB-ZERO WINE STORAGE The importance of the installation of the Sub-Zero Wine Storage unit cannot be overemphasized. Installation should be done by a qualified installer. Before you begin the installation process, it CONTENTS is recommended that you read this entire Installation Instructions book. There are key Models 424 and 424FS Installation 3 details that you should take special care to observe during the installation. By reading Models 427 and 427R Installation 12 these instructions careful

Summary of the content on the page No. 3

MODELS 424 AND 424FS INSTALLATION MODELS 424 AND 424FS MODELS 424 | 424FS SITE PREPARATION INSTALLATION SPECIFICATIONS The Sub-Zero Model 424FS wine storage unit TOP VIEW is designed to be attractive in a stand alone 24" setting. It can also be slid into surrounding (610) ROUGH cabinetry with clearance dimensions slightly OPENING different than the standard built-in Model 424. DEPTH Make sure that the finished rough opening where the Wine Storage unit is to be installed ROUGH OPENING is

Summary of the content on the page No. 4

MODELS 424 AND 424FS INSTALLATION MODELS ELECTRICAL REQUIREMENTS UNPACKING AND MOVING 424 | 424FS A 115 V AC, 60 Hz, 15 amp circuit breaker and Uncrate the unit, remove its wood base and electrical supply are required. A separate discard the shipping bolts that hold the wood circuit, servicing only this appliance, is base to the bottom of the unit. Remove all required. packing materials and tape. The power supply cord has a 3-prong ground- IMPORTANT NOTE: Do not discard the ing plug, which must

Summary of the content on the page No. 5

MODELS 424 AND 424FS INSTALLATION ANTI-TIP BRACKET INSTALLATION MODELS 424 | 424FS MODEL 424FS To prevent the unit from tipping forward If you are installing the Model 424FS in a 5 and provide a stable installation, the unit space deeper than 24 /8" (625), the anti-tip must be secured in place with the anti-tip 5 bracket must be installed no more than 24 /8" bracket. (625) deep, so it engages the unit properly. It is important that this measurement be made from the front surface of the door, to

Summary of the content on the page No. 6

MODELS 424 AND 424FS INSTALLATION MODELS ANTI-TIP BRACKET INSTALLATION 424 | 424FS WOOD FLOOR APPLICATIONS Installation for Concrete Wedge Anchors: 3 1 1) Drill a /8" (10) diameter hole any depth Use the four #12 x 2 /2" wood screws and the 1 exceeding the minimum embedment. Clean four /4" flat washers provided. Drill pilot holes 3 the hole or continue drilling additional /16" (5) diameter maximum, and be sure that depth to accommodate drill fines. Use a the screws penetrate through the flooring

Summary of the content on the page No. 7

MODELS 424 AND 424FS INSTALLATION LOCK INSTALLATION MODELS 424 | 424FS IMPORTANT NOTE: If you are adding an If a home alarm system is to be used with the accessory lock kit to your Wine Storage unit, it Wine Storage unit, the lead wires should be should be installed before you position the threaded into the compressor compartment unit. Installation instructions are included with before you position the unit. See Home Alarm the lock kit. Connections on page 8, for the location of these lead wires

Summary of the content on the page No. 8

MODELS 424 AND 424FS INSTALLATION MODELS LEVEL THE UNIT HOME ALARM CONNECTIONS 424 | 424FS Using an adjustable wrench or pliers, turn Before the kickplate is installed, all necessary each of the four leveling legs clockwise to raise wiring connections in the compressor compart- the unit and counterclockwise to lower the ment should be completed. unit. For the location of the leveling legs, see If a home alarm system is to be installed on illustration 6 below. the Wine Storage unit, the connectio

Summary of the content on the page No. 9

MODELS 424 AND 424FS INSTALLATION KICKPLATE INSTALLATION DOOR PANELS – MODEL 424 MODELS 424 | 424FS Once the unit is leveled and wiring connections Model 424 is offered in two design applica- made, the kickplate can be installed. Use the tions; stainless steel (/S) and overlay (/O). Each 1 two #10 x /2" stainless steel screws that are of these designs are available as a glass door provided with the kickplate. Refer to illustration (G) model. 8 below. The stainless steel Model 424 is available in

Summary of the content on the page No. 10

MODELS 424 AND 424FS INSTALLATION MODELS OVERLAY DOOR PANELS 424 | 424FS OVERLAY GLASS DOOR – MODEL 424 IMPORTANT NOTE: After the first three or four mounting screws are in place, but not 5 Inspect the door panel for the minimum /8" completely tightened, close the door and check (16) thickness, the finished inside edge and the your panel fit. This is the time to make small 10 lbs (5 kg) weight limit. See the Wine adjustments. Once you are satisfied with the Storage section of the Sub-Zero Design

Summary of the content on the page No. 11

MODELS 424 AND 424FS INSTALLATION HINGE ADJUSTMENT MODELS 424 | 424FS IMPORTANT NOTE: Install screws in all the IMPORTANT NOTE: The Wine Storage unit mounting holes in the door frame. The nature must be installed and leveled before door of the door panel with a narrow outer rim and hinge adjustments can be made. no connecting center member requires the The top and bottom cabinet hinges on Models support provided by the glass door. 424 and 424FS are held in place with three After the door panel i

Summary of the content on the page No. 12

MODELS 427 AND 427R INSTALLATION MODELS MODELS 427 AND 427R 427 | 427R INSTALLATION SPECIFICATIONS SITE PREPARATION Make sure that the finished rough opening where the Wine Storage unit is to be installed 25" is properly prepared. Refer to the Installation (635) ROUGH Specifications illustration for rough opening OPENING dimensions, door swing clearance and electri- DEPTH cal placement for Models 427 and 427R. IMPORTANT NOTE: To operate properly, the TOP VIEW door must open a minimum of 90 degre

Summary of the content on the page No. 13

MODELS 427 AND 427R INSTALLATION ELECTRICAL REQUIREMENTS UNPACKING AND MOVING MODELS 427 | 427R A 115 V AC, 60 Hz, 15 amp circuit breaker and Uncrate the unit, remove its wood base and electrical supply are required. A separate discard the shipping bolts that hold the wood circuit, servicing only this appliance, is base to the bottom of the unit. Remove all required. packing materials and tape. The power supply cord has a 3-prong ground- IMPORTANT NOTE: Do not discard the ing plug, which must b

Summary of the content on the page No. 14

MODELS 427 AND 427R INSTALLATION MODELS ANTI-TIP BRACKET INSTALLATION 427 | 427R WOOD FLOOR APPLICATIONS 1 Use the six #12 x 2 /2" wood screws and the To prevent the unit from tipping forward 1 and provide a stable installation, install six /4" flat washers provided. Drill pilot holes 3 the anti-tip bracket and extend the front /16" (5) diameter maximum, and be sure that leveling legs to the floor. the screws penetrate through the flooring material and into the wall plate a minimum of 3 /4" (19)

Summary of the content on the page No. 15

MODELS 427 AND 427R INSTALLATION POSITION THE UNIT MODELS 427 | 427R Installation for Concrete Wedge Anchors: 3 1) Drill a /8" (10) diameter hole any depth Before moving the Wine Storage unit into exceeding the minimum embedment. Clean position, secure the door closed. Remove the hole or continue drilling additional the drawers of the Model 427R. depth to accommodate drill fines. Use a OPTIONAL carbide drill bit manufactured within ANSI COMPONENTS B94.12-77. IMPORTANT NOTE: For Model 427R, the t

Summary of the content on the page No. 16

MODELS 427 AND 427R INSTALLATION MODELS POSITION THE UNIT 427 | 427R IMPORTANT NOTE: If you are adding an If a home alarm system is to be used with the accessory lock kit to your Model 427 or 427R, Wine Storage unit, the lead wires should be the catch should be installed at the top of threaded into the compressor compartment appliance cabinet before you position the unit. before you position the unit. See Other Wiring See Lock Installation on page 23. Installation Connections on page 18 for the

Summary of the content on the page No. 17

MODELS 427 AND 427R INSTALLATION LEVEL THE UNIT MOLDING INSTALLATION MODELS 427 | 427R Level the unit by turning the front leveling legs The decorative white molding strips for the clockwise to raise the unit, or counterclockwise side and top of Models 427 and 427R can be to lower it. To assist you in adjusting the front snapped into place. The top molding piece leveling legs up or down, use a standard must be installed before the side molding can screwdriver blade and place it in the front be a

Summary of the content on the page No. 18

MODELS 427 AND 427R INSTALLATION MODELS OTHER WIRING CONNECTIONS 427 | 427R Before the kickplate/grille is installed, all IMPORTANT NOTE: If you are not responsible necessary wiring connections in the compres- for alarm system connection, this information sor compartment should be completed. should be supplied to the home security system contractor. If the dual installation heater kit (#7007529) is used with Model 427 or 427R, the power OPTIONAL supply leads should be connected according to COMP

Summary of the content on the page No. 19

MODELS 427 AND 427R INSTALLATION KICKPLATE / GRILLE INSTALLATION MODELS 427 | 427R Once the unit is leveled and wiring connec- Stainless steel panels in three finishes in most tions made, the kickplate/grille can be cases; classic (/S), platinum (/P) and carbon installed. (/B)—available as sales accessories—may be configured several ways and are shipped IMPORTANT NOTE: The kickplate/grille must separately. Stainless steel panels are shipped be removed for servicing. The floor cannot PANEL with m

Summary of the content on the page No. 20

MODELS 427 AND 427R INSTALLATION MODELS STAINLESS STEEL DOOR PANEL OVERLAY GLASS DOOR PANEL 427 | 427R 5 Before installing the stainless steel door panel, Inspect the door panel for the minimum /8" check the panel carefully. Options are available (16) thickness, the greater width requirements for kickplate/grille height, overall height, door for the stiles (to cover the door hinges), and swing and door lock. the finished inside edge. The door panel has a weight limit of 20 lbs (9 kg). See the Wi


Alternative user manuals
# User manual Category Download
1 Sub-Zero 427R User manual Beverage Dispenser 6
2 Sub-Zero 430/F User manual Beverage Dispenser 2
3 Sub-Zero 430/O User manual Beverage Dispenser 1
4 Sub-Zero ICB424 User manual Beverage Dispenser 2
5 Sub-Zero 424FS User manual Beverage Dispenser 2
6 Sub-Zero ICB427 User manual Beverage Dispenser 0
7 Sub-Zero WINE STORAGE User manual Beverage Dispenser 9
8 Sub-Zero Sub Zero Wine Storage 315W User manual Beverage Dispenser 0
9 Sub-Zero ICB427R User manual Beverage Dispenser 1
10 Sub-Zero ICB424FS User manual Beverage Dispenser 0
11 Sub-Zero ICB430 User manual Beverage Dispenser 0
12 Sub-Zero WS-30 User manual Beverage Dispenser 0
13 Sub-Zero 400 Series Wine/Storage Refrigerator 427RGLH User manual Beverage Dispenser 0
14 Sony KDL-40V4100 User manual Beverage Dispenser 4
15 Sony KDL-46V4100 User manual Beverage Dispenser 2
16 Sony KDL-40W4100 User manual Beverage Dispenser 3
17 Sony KDL-40V4150 User manual Beverage Dispenser 2
18 Sony KDL-46W4150 User manual Beverage Dispenser 1