Cornelius Impulse Non-Carbonated Post-Mix user manual

User manual for the device Cornelius Impulse Non-Carbonated Post-Mix

Device: Cornelius Impulse Non-Carbonated Post-Mix
Category: Beverage Dispenser
Manufacturer: Cornelius
Size: 1.35 MB
Added : 4/21/2014
Number of pages: 20
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Cornelius Impulse Non-Carbonated Post-Mix. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Cornelius Impulse Non-Carbonated Post-Mix.

For your convenience

If looking through the Cornelius Impulse Non-Carbonated Post-Mix user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Cornelius Impulse Non-Carbonated Post-Mix on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Cornelius Impulse Non-Carbonated Post-Mix to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Cornelius Impulse Non-Carbonated Post-Mix User manual - Online PDF
Advertisement
« Page 1 of 20 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Cornelius Impulse Non-Carbonated Post-Mix but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Cornelius Impulse Non-Carbonated Post-Mix. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
IMPULSE
Non-Carbonated Post-Mix Beverage Dispenser
Installation & Operation Manual
Release Date: December 16, 2003
Publication Number: 859000159INS
Revision Date: NA
Revision: A
www.cornelius.com

Summary of the content on the page No. 2

Impulse Installation and Operation Manual CONTACT INFORMATION This an abbreviated manual. Keep this manual in case there are questions about operating the unit. The products, technical information, and instructions contained in this manual are subject to change with- out notice. These instructions are not intended to cover all details or variations of the equipment, nor to provide for every possible contingency in the installation, operation or maintenance of this equipment. This manual assu

Summary of the content on the page No. 3

Impulse Installation and Operation Manual TABLE OF CONTENTS SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Recognize safety alerts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Authorized Service Personnel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 CO2 (Carbon Dioxide) Warning . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 4

Impulse Installation and Operation Manual Publication Number: 859000159INS - ii - © 2003, IMI Cornelius Inc.

Summary of the content on the page No. 5

Non-Carbonated Impulse Installation & Operations Manual SAFETY RECOGNIZE SAFETY ALERTS This is the safety alert symbol. When you see it in this manual or on the AUTHORIZED SERVICE PERSONNEL CAUTION — Only trained and certified electrical, plumbing and refrigeration techni- cians should service this unit. ALL WIRING AND PLUMBING MUST CONFORM TO NATIONAL AND LOCAL CODES. CO (CARBON DIOXIDE) WARNING 2 WARNING — CO Displaces Oxygen. Strict Attention must be observed in the pre- 2 vention of CO gas

Summary of the content on the page No. 6

Non-Carbonated Impulse Installation & Operations Manual INSTALLATION CAUTION — Only trained and certified electrical, plumbing and refrigeration techni- cians should service this unit. ALL WIRING AND PLUMBING MUST CONFORM TO NATIONAL AND LOCAL CODES. NOTE: Water pipe connections and fixtures directly connected to the potable water supply must be sized, installed, and maintained in accordance with NSF Standard 18, as well as Federal, State, and Local codes. NOTE: It is the installer’s resp

Summary of the content on the page No. 7

Non-Carbonated Impulse Installation & Operations Manual INSTALLATION PROCEDURE Counter-top Installation NOTE: Optional 4-inch legs (p/n 3184) will elevate the unit 4 inches above counter (order 4 legs). 1. Place the unit on a level counter capable of supporting at least 400 pounds. 2. Remove drip tray and front access panel. 3. Turn power switch off then remove screw located next to the power switch and the screw at top of front panel. Next, remove front panel, disconnect wires to valve key

Summary of the content on the page No. 8

Non-Carbonated Impulse Installation & Operations Manual NOTE: Make sure that the electrical power circuit breaker is switched off or the fuse removed. Before connecting electrical power to the unit, refer to nameplate to verify the power require- ments. A. Remove the following: • front merchandiser by removing two screws on the top and lifting up • key switch wires • hood by removing two screws on the top and lifting up and forward. B. Remove second valve from the left to facilitate routi

Summary of the content on the page No. 9

Non-Carbonated Impulse Installation & Operations Manual Adjusting Flow Rates Flow rates of the water and concentrate are adjusted based on the desired ratio. For example: if the desired ratio is 5:1, then the flow rate of the water is 5 times that of the concentrate. If the desired finished drink flow rate is 3.0 ounces per second, then the water flow rate is 2.5 oz./sec. and the concentrate flow rate is 0.5 oz./sec. (The water at 2.5 oz./sec. is five times the 0.5 oz./sec. con- centrate flow

Summary of the content on the page No. 10

Non-Carbonated Impulse Installation & Operations Manual OPERATIONS OPERATIONS Starting And Stopping the Unit ON/OFF switch Key-lock switch 1. Push power ON/OFF switch to ON to power on the unit. 2. Insert key into key lock and turn to the ON to activate valves. Dispensing Product To dispense beverage press a cup or glass against the lever or push the button on the valve cover. Replenishing Concentrate Supply Bag-In-Box System: 1. Disconnect the concentrate tube from the empty bag-in-box and remo

Summary of the content on the page No. 11

Non-Carbonated Impulse Installation & Operations Manual CLEANING & CHECKS Daily Cleaning 1. Remove nozzle assembly and rinse with warm (not hot) water. If possible, soak nozzle assembly over night in carbonated water then rinse with warm water. Diffuser Nozzle 2. Wash external surfaces with mild soap solution, rinse with clean water, and wipe dry. Remove the drip tray, wash with mild soap solution, rinse and dry. NOTE: Do not use abrasive or harsh cleaners on the unit. Daily Checks 1. Check C

Summary of the content on the page No. 12

Non-Carbonated Impulse Installation & Operations Manual 2. Connect potable water source to the remaining concentrate systems and flush detergent solution out of the concentrate systems as instructed in step 9 preceding. 3. Remove potable water source from the concentrate system. STEP 3. Sanitize Concentrate Systems o o 1. Using five-gallon container (bag-in-box system), prepare sanitizing solution using 70 F (21 C) o o to100 F (38 C) potable water and 0.5 oz. (15 ml) of non-scented household l

Summary of the content on the page No. 13

Non-Carbonated Impulse Installation & Operations Manual REFERENCE MATERIAL WIRING DIAGRAM © 2003, IMI Cornelius Inc. - 9 - Publication Number: 859000159INS

Summary of the content on the page No. 14

Non-Carbonated Impulse Installation & Operations Manual PLUMBING DIAGRAMS Internal Carbonator COOLING COILS CARBONA TED WA T E R MANIFOLD NON-CARBONA TED DRINK 1 2 PLAIN WA T E R CO2 CHECK 3 VALVE 4 5 REMOTE CARBONA TOR REGULA TED CO2 SUPPLY 6 DISPENSER DISPENSING VALVE (6) SYRUP SUPPLY (SYRUP TANKS OR BAG-IN-BOX SYSTEM) LINE LEGEND CO2 PLAIN WATER SYRUP CARB WATER External Carbonator Publication Number: 859000159INS - 10 - © 2003, IMI Cornelius Inc.

Summary of the content on the page No. 15

Non-Carbonated Impulse Installation & Operations Manual © 2003, IMI Cornelius Inc. - 11 - Publication Number: 859000159INS

Summary of the content on the page No. 16

Non-Carbonated Impulse Installation & Operations Manual TROUBLESHOOTING Trouble Probable Cause Remedy Troubleshooting Dispensing System WATER-TO-CONCENTRATE • Dispensing valve concentrate • Adjust Water-to-Concentrate “RATIO”TOO LOW OR TOO flow regulator not properly “Ratio” as instructed. HIGH. adjusted. • CO2 gas pressure to concen- • Adjust concentrate pumps CO2 trate pumps insufficient to oper- regulator as instructed. ate pumps. ADJUSTMENT OF DISPENSING • No concentrate supply. • Replenis

Summary of the content on the page No. 17

Non-Carbonated Impulse Installation & Operations Manual Troubleshooting Refrigeration System COMPRESSOR DOES NOT • Ice bank sufficient. • Refrigeration not called for. OPERATE. • Unit power cord unplugged or • Plug in power cord or place control board power switch in switch in “ON” position. “OFF” position. • No power source (blown fuse or • Replace fuse or reset circuit tripped circuit breaker). breaker (note: Fuse or circuit breaker are not part of unit). • Low voltage at compressor ter- •

Summary of the content on the page No. 18

Non-Carbonated Impulse Installation & Operations Manual • No power source. Blown fuse • Replace fuse or reset circuit or. tripped circuit breaker breaker (note: Fuse or circuit breaker are not part of unit). • Agitator motor propeller • Remove obstruction. obstructed. • Low voltage at compressor ter- • Voltage must be at least 103 minals. volts at the compressor termi- nals when compressor is trying to start. • Loose, disconnected, or bro- • Tighten connections or replace ken wiring. broken

Summary of the content on the page No. 19

blank

Summary of the content on the page No. 20

IMI Cornelius Inc. One Cornelius Place Anoka, MN 55303-1592 U.S.A.


Alternative user manuals
# User manual Category Download
1 Cornelius 1522 User manual Beverage Dispenser 12
2 Cornelius 318569000 User manual Beverage Dispenser 1
3 Cornelius 2232MS User manual Beverage Dispenser 0
4 Cornelius 318948000 User manual Beverage Dispenser 1
5 Cornelius 318949000 User manual Beverage Dispenser 25
6 Cornelius 569000261 User manual Beverage Dispenser 0
7 Cornelius 18368 User manual Beverage Dispenser 0
8 Cornelius 230 VAC User manual Beverage Dispenser 2
9 Cornelius 2 Flavor Post-Mix Cold Coffee Dispenser Quest 2000 User manual Beverage Dispenser 1
10 Cornelius 569000262 User manual Beverage Dispenser 0
11 Cornelius 326142000 User manual Beverage Dispenser 2
12 Cornelius 50Hz User manual Beverage Dispenser 1
13 Cornelius 560003869 User manual Beverage Dispenser 0
14 Cornelius 560003870 User manual Beverage Dispenser 0
15 Cornelius A8531 User manual Beverage Dispenser 0
16 Sony KDL-40V4100 User manual Beverage Dispenser 4
17 Sony KDL-46V4100 User manual Beverage Dispenser 2
18 Sony KDL-40W4100 User manual Beverage Dispenser 3
19 Sony KDL-40V4150 User manual Beverage Dispenser 2
20 Sony KDL-46W4150 User manual Beverage Dispenser 1