Cornelius Enduro ED-250 BCP user manual

User manual for the device Cornelius Enduro ED-250 BCP

Device: Cornelius Enduro ED-250 BCP
Category: Beverage Dispenser
Manufacturer: Cornelius
Size: 0.23 MB
Added : 4/21/2014
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Cornelius Enduro ED-250 BCP. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Cornelius Enduro ED-250 BCP.

For your convenience

If looking through the Cornelius Enduro ED-250 BCP user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Cornelius Enduro ED-250 BCP on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Cornelius Enduro ED-250 BCP to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Cornelius Enduro ED-250 BCP User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Cornelius Enduro ED-250 BCP but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Cornelius Enduro ED-250 BCP. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

www.cornelius.com
Installation Manual
ENDURO ICE/BEVERAGE DISPENSER
Model: ED-250 BCP
IMPORTANT:
TO THE INSTALLER.
It is the responsibility of
the Installer to ensure that
the water supply to the
dispensing equipment is
provided with protection
against backflow by an air
gap as defined in
ANSI/ASME A112.1.2-1979;
or an approved vacuum
breaker or other such
method as proved effective
by test.
Water pipe connections
and fixtures directly
connected to a potable
water supply shall be
sized, installe

Summary of the content on the page No. 2

TABLE OF CONTENTS Page SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 INSTALLATION INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 3

RETAINER ICE BIN COVER ICE AGITATOR MANUAL ICE DISPENSE RED PUSH BUTTON SWITCH ICE PORTION CONTROL MODULE BEVERAGE FAUCET ON/OFF SWITCH REMOVABLE STRAW MANUAL/AUTO ICE HOLDER PANEL TOGGLE SWITCH LID/STRAW HOLDER CUP REST DRIP TRAY BEVERAGE FAUCETS (8) LOWER ACCESS PANEL FIGURE 1. PARTS IDENTIFICATION 1 620916501INS

Summary of the content on the page No. 4

SAFETY PRECAUTIONS Always: Disconnect power to the dispenser before servicing or cleaning. Never: Place hands inside of hopper or gate area without disconnecting power to the dispenser. Agitator rotation occurs automatically when dispenser is energized! This ice dispenser has been specifically designed to provide protection against personal injury and eliminates contamination of ice.To insure continued protection and sanitation, observe the following: ALWAYS: Be sure the removable lid is proper

Summary of the content on the page No. 5

INSTALLATION INSTRUCTIONS 1. Locate the dispenser indoors on a level counter top. The ice dispenser must be sealed to the counter. The MOUNTING TEMPLATE (see Figure 3) indicates where openings can be cut in the counter. Locate the desired position for the dispenser, then mark the outline dimensions on the counter using the MOUNTING TEMPLATE. Cut openings in the counter. Rotate the line support bracket, located under base, to the up position and route all the lines below the bracket. Apply a co

Summary of the content on the page No. 6

SOLVENT BOND HOSE CLAMP DRIP TRAY DRAIN FITTING COUPLING 3/4 SOCKET X 3/4 FPT BARB ADAPTER 1 BARB X 3/4 MPT DRAIN LINE 1-IN. I.D. PLASTIC TUBING (6 FT) WITH INSULATION FIGURE 2. DRIP TRAY DRAIN ASSEMBLY 4 620916501INS

Summary of the content on the page No. 7

30 26–7/16 1–13/16 1–5/16 23 7/16 12 21–1/4 9 21–1/4 18–5/8 23–1/16 OPENING 29 30–11/16 3–1/2 REMOVABLE DRIP TRAY Z STYLE 9–3/16 11–5/8 TO FRONT OF DRIP TRAY ON COUNTERTOP TO FRONT TOP OF RECOMMENDED COUNTER OPENING SIZE DRIP TRAY 9.00 X 12.00 FOR UTILITIES AND BEVERAGE TUBING. OPENING CAN BE LOCATED ANYWHERE WITHIN THE SHADED AREA. FIGURE 3. MOUNTING TEMPLATE 5 620916501INS

Summary of the content on the page No. 8

FAUCETS VIEWED FROM THIS SIDE FIGURE 4. FLOW DIAGRAM (UNIT WITH EIGHT FAUCETS) 620916501INS 6 Non–Carb Water Carb Water FAUCETS OPTIONAL PRESSURE REGULATOR 1 CHECK S1 POTABLE VALVE WATER W1 2 FILTER SUPPLY S2 CARBONATOR INSTALL FOR 3 NON–CARB AS S3 W2 REQUIRED CO2 4 S4 S1 Carb Water S2 S3 S4 W1 W2 COLDPLATE INLET W3 CONNECTIONS W4 S5 S6 S7 S8 OPTIONAL FOR 5 DIET DRINKS S5 OR ROOT BEER W4 5–15 6 PSIG S6 CO2 7 Cylinder W3 S7 8 S8 S7 S6 S5 S4 S3 S2 S1 S8 SYRUP TANKS COLD PLATE 15–50 PSIG PRESSURE R

Summary of the content on the page No. 9

7 620916501INS PNEUMATIC GATE SOLENOID VALVE FILTER–REGULATOR 3-WAY NORMALLY CLOSED (FACTORY-SET OUTLET PRESSURE TO 32-36 PSIG) CO2 SUPPLY 50 PSIG MAX. MANUAL OVERIDE SOLENOID VALVE ICE GATE CYLINDER REVERSE 3-WAY NORMALLY CLOSED SINGLE ACTING-SPRING EXTENDED FIGURE 5. FLOW DIAGRAM (PNEUMATIC ICE GATE)

Summary of the content on the page No. 10

ED250 PROGATE WIRING DIAGRAM L MOTOR INTERLOCK N INCOMING POWER HEATER RELAY E ICE CHUTE INTERLOCK 7A BLK TO GUSSET SWITCH HINGE GROUND TERMINAL TERMINAL GRN/YEL BOARD 5B GRN/YEL BLK BLK BLK TO EBOX BLK WHT GROUND SCREW BLK YEL BLK WHT WHT BLK WHT BLK WHT WHT DIODE BLK WHT BLK WHT LINE LINE TRANSFORMER TRANSFORMER YEL LOAD LOAD RED YEL/BLK YEL ORN/BLK ORN 123 45 WHT WHT 123 45 YEL YEL RED YEL/BLK YEL ORN/BLK ORN AGITATOR MOTOR START MOTOR CAPACITOR BLK WHT BLK WHT GRN/YEL BEVERAGE BEVERAGE VALVE

Summary of the content on the page No. 11

L N 120V ICE CHUTE INTERLOCk SWITCH INTERLOCK RELAY BEVERAGE TRANSFORMER BEVERAGE 24VAC TRANSFORMER 24VAC 24VAC BEV ON/OFF SWITCH MANUAL OVERIDE SOLENOID VALVE MANUAL/AUTO ICE BEV BEV TOGGLE SWITCH VAL. VAL. BEV BEV VAL. VAL. BEV BEV VAL. VAL. BEV BEV VAL. VAL. 24VAC 1 3 AGITATOR PORTION CONTROLLER/ TOUCH RELAY TOUCH PANEL PANEL 2 4 PNEUMATIC ICE GATE SOLENOID VALVE AGITATOR MOTOR 3 MANUAL ICE DISPENSE O/L R SWITCH 2 4 S START CAPACITOR MOTOR AGITATOR MOTOR START RELAY HEATER 9 620916501INS FIGU

Summary of the content on the page No. 12

THIS PAGE LEFT BLANK INTENTIONALLY 10 620916501INS

Summary of the content on the page No. 13

TROUBLESHOOTING IMPORTANT: Only qualified personnel should service internal components or electrical wiring. WARNING: If repairs are to be made to the beverage system, remove quick disconnects from the applicable product tank, then relieve the system pressure before proceeding. If repairs are to be made to the CO system, stop dispensing, shut off the CO supply, then 2 2 relieve the system pressure before proceeding. If repairs are to be made to the ice dispensing system, make sure electrical

Summary of the content on the page No. 14

Trouble Probable Cause Remedy NO ICE DISPENSED FROM ICE ICE POR PORTION TION CONTROLLER CONTROLLER D. Insufficient or no CO supply D. Restore CO supply to dispenser. 2 2 (CONTINUED) to dispenser. E. Ice chute cover not properly E. Make sure that cover is “snapped” Installed. into place. F. Defective ice chute interlock F. Replace interlock switch. switch. G. Defective interlock relay. G. Replace relay. H. Defective 24V transformer. H. Replace transformer. I. Defective portion controller. I. Rep

Summary of the content on the page No. 15

WARRANTY IMI Cornelius Inc. warrants that all equipment and parts are free from defects in material and workmanship under normal use and service. For a copy of the warranty applicable to your Cornelius product, in your country, please write, fax or telephone the IMI Cornelius office nearest you. Please provide the equipment model number and the date of purchase. IMI Cornelius Offices AUSTRALIA  P.O. 210,  RIVERWOOD,  NSW 2210, AUSTRALIA  (61) 2 533 3122  FAX (61) 2 534 2166 AUSTRIA  AM LAN

Summary of the content on the page No. 16

IMI CORNELIUS INC.


Alternative user manuals
# User manual Category Download
1 Cornelius 1522 User manual Beverage Dispenser 12
2 Cornelius 318569000 User manual Beverage Dispenser 1
3 Cornelius 2232MS User manual Beverage Dispenser 0
4 Cornelius 318948000 User manual Beverage Dispenser 1
5 Cornelius 318949000 User manual Beverage Dispenser 25
6 Cornelius 569000261 User manual Beverage Dispenser 0
7 Cornelius 18368 User manual Beverage Dispenser 0
8 Cornelius 230 VAC User manual Beverage Dispenser 2
9 Cornelius 2 Flavor Post-Mix Cold Coffee Dispenser Quest 2000 User manual Beverage Dispenser 1
10 Cornelius 569000262 User manual Beverage Dispenser 0
11 Cornelius 326142000 User manual Beverage Dispenser 2
12 Cornelius 50Hz User manual Beverage Dispenser 1
13 Cornelius 560003869 User manual Beverage Dispenser 0
14 Cornelius 560003870 User manual Beverage Dispenser 0
15 Cornelius A8531 User manual Beverage Dispenser 0
16 Sony KDL-40V4100 User manual Beverage Dispenser 4
17 Sony KDL-46V4100 User manual Beverage Dispenser 2
18 Sony KDL-40W4100 User manual Beverage Dispenser 3
19 Sony KDL-40V4150 User manual Beverage Dispenser 2
20 Sony KDL-46W4150 User manual Beverage Dispenser 1