APC Back UPS BR1000G user manual

User manual for the device APC Back UPS BR1000G

Device: APC Back UPS BR1000G
Category: Battery Charger
Manufacturer: APC
Size: 0.23 MB
Added : 10/3/2013
Number of pages: 8
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for APC Back UPS BR1000G. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with APC Back UPS BR1000G.

For your convenience

If looking through the APC Back UPS BR1000G user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual APC Back UPS BR1000G on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual APC Back UPS BR1000G to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
APC Back UPS BR1000G User manual - Online PDF
Advertisement
« Page 1 of 8 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual APC Back UPS BR1000G but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to APC Back UPS BR1000G. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
Back-UPS Pro 1000 Installation and
Operation
Inventory Safety
Do not install the Back-UPS in direct
sunlight, in excessive heat,
humidity, or in contact with fluids.
Connect the battery
 

®
Install PowerChute Personal Edition Software
APC PowerChute Personal Edition software provides automatic file saving and shutdown of
your computer in the event of a power failure. Use the cable supplied with the Back-UPS to
connect the data port on the Back-UPS to the USB port on your computer.

Summary of the content on the page No. 2

Connect the equipment Battery Backup and Surge Protected outlets When the Back-UPS is receiving input power, the Battery Backup with Surge Protection outlets will supply power to connected equipment. During a power outage or other utility problems, the Battery Backup outlets receive power for a limited time from the Back-UPS. Connect equipment such as printers, fax machines, scanners, or other peripherals that do not need battery backup power to the Surge Protection Only outlets. These

Summary of the content on the page No. 3

Operation Power-Saving Function To conserve electricity, configure the Back-UPS to recognize a Master device, such as a desktop computer or an A/V receiver, and Controlled peripheral devices, such as a printer, speakers, or a scanner. When the Master device goes into Sleep or Standby mode, or is switched OFF, the Controlled device(s) will be switched off as well, saving electricity. Enable the Power-Saving function. Press and hold MUTE and DISPLAY simultaneously for two seconds. The Back-UPS

Summary of the content on the page No. 4

Front Panel Buttons and Display Interface Use the three buttons on the front panel of the Back-UPS and the display interface to configure the Back-UPS. Front panel Mute button  Power On/Off button  Display button  Display interface  On Line—The Back-UPS is supplying conditioned utility power to connected equipment Power-Saving—Master and Controlled outlets are enabled, saving power when the master device goes into sleep or standby mode Load Capacity—The load is indicated by the number of se

Summary of the content on the page No. 5

Warnings and System Faults Audible Warnings Back-UPS is running on battery. You should consider saving any work in progress. Four Beeps Every 30 Seconds Low battery condition and battery run-time is very low. Promptly save any work in progress, exit Continuous Beeping all open applications, and shut down the operating system. Battery Backup outputs are overloaded. Continuous tone Battery fails the automatic diagnostic test and should be replaced. Chirps for 1 Minute every 5 hours Warning Icon

Summary of the content on the page No. 6

Function Button Quick-Reference Timing UPS Function Button Description (seconds) Status Power Power On Press POWER to start receiving input utility power. If A/C input 0.2 Off power is not available, the Back-UPS will run on battery power. Power Off The Back-UPS is not receiving input utility power, but is providing 2On surge protection. Display Status Inquiry Verify the status or condition of the Back-UPS. The LCD will 0.2 On illuminate for 60 seconds. Full-Time/Power- The LCD will illumin

Summary of the content on the page No. 7

Troubleshooting Problem Possible Cause Corrective Action Back-UPS will not switch on. The Back-UPS is not connected to utility Ensure that the Back-UPS is securely connected power. to an AC outlet. The circuit breaker has been tripped. Disconnect non-essential equipment from the Back-UPS. Reset the circuit breaker. Re-connect equipment one item at a time. If the circuit breaker is tripped again, disconnect the device that caused the trip. The internal battery is not connected. Connect the b

Summary of the content on the page No. 8

Specifications Replacement Battery t The battery cartridge typically lasts 3 to 6 years, a VA 1000 VA shorter period if subjected to frequent outages or Maximum Load 600 W elevated temperatures. Battery replacement part for Nominal Input Voltage 120 V Back-UPS Pro 1000 is APCRBC123. Please recycle spent battery cartridges. Online Input Voltage Range 88 - 141 V Automatic Voltage Regulation (94-107) +11.2% Service (126-141) -11.2% If the Back-UPS arrived damaged, notify the carrier. Frequency


Alternative user manuals
# User manual Category Download
1 APC 230V User manual Battery Charger 27
2 APC RBC145J User manual Battery Charger 2
3 APC Back UPS 1500 User manual Battery Charger 287
4 APC AP9924 User manual Battery Charger 0
5 APC 865 W User manual Battery Charger 5
6 APC Back UPS 1400 VA User manual Battery Charger 644
7 APC 2200 VA User manual Battery Charger 1
8 APC AP9927 User manual Battery Charger 1
9 APC Back UPS 200 User manual Battery Charger 55
10 APC Back UPS 450 User manual Battery Charger 42
11 APC Back UPS BE325-FR/ User manual Battery Charger 66
12 APC Back UPS BE450G User manual Battery Charger 33
13 APC Back UPS 650 VA User manual Battery Charger 337
14 APC Back UPS BE325-UK User manual Battery Charger 19
15 APC Back UPS 420 VA User manual Battery Charger 38
16 Craftsman 950138 User manual Battery Charger 1
17 Sony AC-L200 User manual Battery Charger 23
18 Sony AC VQ800 User manual Battery Charger 11
19 Sony AC SQ950D User manual Battery Charger 9
20 Sony AC V700A User manual Battery Charger 11