Summary of the content on the page No. 1
COMPACT 155 Mbit/s
ADD-DROP MULTIPLEXER
MULTIPLEXEUR ADD-DROP
à 155 Mbit/s COMPACT
ADR 155C
Installation and User Guide
Guide d'Installation et d'Utilisation
N56717020101
Issue : April 2000
Edition : Avril 2000
Summary of the content on the page No. 2
Summary of the content on the page No. 3
COMPACT 155 Mbit/s ADD-DROP MULTIPLEXER MULTIPLEXEUR ADD-DROP à 155 Mbit/s COMPACT ADR 155C Installation and User Guide Guide d'Installation et d'Utilisation N56717020101 Issue : April 2000 Edition : Avril 2000
Summary of the content on the page No. 4
LIST OF CHANGES REPERTOIRE DES MISES A JOUR (A new edition replaces any previous versions) (Une nouvelle édition annule et remplace la précédente) No/N° Date/Date Change description/Description de la Page/Page mise à jour 0101 April 2000/ Creation of original user guide/ All pages/ Avril 2000 Création du document à l'édition originale Toutes pages Remarque importante : La version logicielle actuelle n'offre pas la fonction RIP décrite dans ce guide. Important remark : The current software versio
Summary of the content on the page No. 5
COMPACT 155 Mbit/s ADD-DROP MULTIPLEXER ADR 155C Installation and User Guide Installation and User Guide - N56717020101 Reproduction and communication in any form prohibited without the written permission of ( Page A0-1
Summary of the content on the page No. 6
PORTS SECURITY LEVEL Port safety level for the 19" subrack access The connectors are identified on the front panels of the equipment (cards or motherboard). Connectors Function Security level 1 PWRA/PWRB Power supply SELV PWR Power supply SELV Motherboard SYNC G.703 2 Mbit/s synchronization Ports SELV E1 INPUT & E1 OUTPUT G.703 2 Mbit/s Ports SELV MNGT Other equipment connection SELV COMM VT100 local supervision SELV ETH Ethernet LAN remote supervision SELV LOOPS Loops and remote signaling SELV
Summary of the content on the page No. 7
CONTENTS CHANGE LIST 0-2 SECTION A : Installation and user guide ...................... A0-1 to AA-6 PORTS SECURITY LEVEL A0-2 CONTENTS A0-3 to A0-4 1. INSTALLATION AND COMMISSIONING ........................................................... A1-1 to A1-28 1.1 - General A1-1 1.2 - Subrack installation A1-3 1.3 - Connecting ports A1-4 1.3.1 - Connecting Power Supply A1-4 1.3.2 - Connecting on motherboard A1-7 1.3.3 - Connecting on the ADR IC1.x card A1-13 1.3.4 - Connecting on ADR LAN1 card A1-1
Summary of the content on the page No. 8
Figure 2-1 Synchronization from the 2 MHz external sync input (T3) A2-10 Figure 2-2 Synchronization from the 2 MHz port A2-10 Figure 2-3 Remote loopback function (registering alarms on central site) A2-11 Tables 2-1 to 2-6 Configuration parameters A2-2 to A2-7 Tables 2-7 to 2-8 Commands A2-8 to A2-9 Tables 2-9 to 2-10 Alarms and severity A2-13 to A2-14 3. SPARE PARTS....................................................................................................... A3-1 to A3-2 4. SPECIFICATI
Summary of the content on the page No. 9
1 - INSTALLATION AND COMMISSIONING 1. INSTALLATION AND COMMISSIONING 1.1 - General The ADR 155C is an optical STM-1 add-drop multiplexer used to build STM-1 point-to-point links, STM-1 rings, or mesh networks with conduct (SNC) or line (MSP) protection, so performing the conveyance of links at 2 Mbit/s, Ethernet, STM-1. The ADR 155C can be used as: STM-1 terminal multiplexer with maximum capacity of 63 VC12 and capability of 1+1 protection, STM-1 repeater, capability of regenerating 2 VC4,
Summary of the content on the page No. 10
2 2 1 - INSTALLATION AND COMMISSIONING P B A V D M C ADR 155C Subrack Left uprights of rack ADR 155C ADR 155C ETSI RACK 19" SUBRACK 66 ( 3 7 66 ( 3 7 2 2 Two M6x12 Two M6x12 1 1 HM screw HM screw Two M6 Two M6 cage nuts cage nuts 19" rack mounting ETSI rack mouting Figure 1-1- ADR155C Subrack Installation Installation and User Guide - N56717020101 Page A1-2 No reproduction or communication without the written consent of SAGEM SA 76,2 mm 2U 76,2 mm 2U 87 738 87 28 ( <1& <1& 87 738 87 28 <1& (
Summary of the content on the page No. 11
1 - INSTALLATION AND COMMISSIONING 1.2 - Subrack installation The ADR 155C subrack can be installed in 19" rack or ETSI frame (see Figure 1-1). It consists of: a motherboard located in the lower part (item M), four non-dedicated slots (items A to D), designed to accommodate the traffic cards, a slide located on the left of the subrack designed to accommodate the ventilation module (item V), a power supply (item P). All connections are performed on front panel, either on the subrack, or o
Summary of the content on the page No. 12
1 - INSTALLATION AND COMMISSIONING 1.3 - Connecting ports The connections to be performed on the equipment depend on the configuration chosen: On the power supply card: poser supply ports: "PWR" or "PWRA" and/or "PWRB", On the subrack motherboard strip: management ports : "COMM", "ETH" and/or "MNGT" Remote indication, remote control and station alarm port : "LOOPS" 2Mbit/s G.703 synchronization port : "SYNC" 21x2Mbit/s G.703 traffic ports: "E1 INPUT" and "E1 OUTPUT". Depending on the t
Summary of the content on the page No. 13
1 - INSTALLATION AND COMMISSIONING Description of power supply ports POWER - 48V 2A MAX "PWR" Jack type connector F4AL250V Fuse 4A Quick fuse low power shutdown 250V PWRA and PWRB 1 - 48 B1 5 2 - 48 B1 6 OB1 9 3 - Reserved 7 OB1 6 4 - 48 B2 8 OB2 1 5 - 48 B2 9 OB2 ADR-155C Figure 1-2 – Connecting power supply ports "PWRA"/"PWRB" power supply interface: Input voltage : One or two Safety Extra Low Voltage (SELV) ty
Summary of the content on the page No. 14
1 - INSTALLATION AND COMMISSIONING LOOPS 8 1 9 15 1 : Break B 2 : Make B 9 : Common B 3 : Common A 10 : Break A 4 : Gnd 11 : Make A 5 : R-MON 4 N 12 : R-MON 4 P (OB) "SYNC" 6 : R-MON 3 N 13 : R-MON 3 P (OB) 5 1 7 : R-MON 2 N 14 : R-MON 2 P (OB) 8 : R-MON 1 N 15 : R-MON 1 P (OB) 6 9 Schematic diagram 1 : GND of a dry loop 2 : TX1_TIP 6 : TX1_RING 3 : RX1_TIP 7 : RX2_TIP M 4 : RX2_RING 8 : RX1_RING CB 5 : RESERVED 9 : RESERVED "E1 OUTPUT"and "E1 INPUT" 15 1 30 16 Green "
Summary of the content on the page No. 15
1 - INSTALLATION AND COMMISSIONING 1.3.2 - Connecting on motherboard 1.3.2.1 - Remote indication, remote control and station alarm port ("LOOPS") "LOOPS" Interface: Ports 4 remote indication inputs for floating contacts (Local user inputs), biased to -48 V internally, active when closed and with electrical isolation (loop current = from 1 to 10 mA), 2 dry loop outputs (common, normally closed and normally open) (Local user outputs) for station alarm or remote control use (maximum current = 1
Summary of the content on the page No. 16
1 - INSTALLATION AND COMMISSIONING NOTE: Two LEDs are linked to the "ETH" port: • LED, "Activity", green colour : Trafic status indicator, • LED, "Link", yellow colour : Link status indicator. 1.3.2.2 - Management and Administration ports "COMM" Interface: Ports RS232, connecting VT100 standard console or emulation Bit rate 19200 bauds (8 data bits, no parity bit and 1 stop bit), Connector Female 9-way HE5 5 1 9 6 Pin N° Signal name Comments 1 DCD Connected to DSR 6 DSR Data Set Ready (to DCE)*
Summary of the content on the page No. 17
1 - INSTALLATION AND COMMISSIONING "MNGT" Interface: Port V.11 synchronous (differential) interconnection possible with other SAGEM equipment ADR155C, FOT 155C, through serial synchronous links used in codirectional mode at 64 kbit/s or master contra-directional mode (rate defined by the ADR 155C) Bit rate 64 kbit/s, Connector Female 9-way HE5. 5 1 9 6 Pin N° Signal name Polarity Comments 1 GND Ground (no connected) 6RXPB (+) Input for data received over the P interface and sampled on the rising
Summary of the content on the page No. 18
1 - INSTALLATION AND COMMISSIONING 1.3.2.3 - G.703 2 Mbit/s Synchronization port "SYNC" Interface Ports Two G.703 2MHz external synchronization inputs (T3) and one G.703 2MHz clock output (T4) compliant with ITU-T G.703 Recommendation (§ 10.3 for input port, § tab.10 for output port) Bit rate 2,048 Mbit/s ± 50 ppm, Impedance 120 Ω balanced, Connector Female 9-way HE5 (120 Ω). 5 1 6 9 Pin N° Signal name Comments 1 GND Ground 6 TX1 RING (T4-) Output T4-1 (cold point) 2 TX1 TIP (T4+) Output T4-1
Summary of the content on the page No. 19
1 - INSTALLATION AND COMMISSIONING Pin N° Ports Signal name C omments 16 GND ground 31 1 TX(RX) 1B Output (Input) 2 Mbit/s (hot point) 1 TX(RX) 1A Output (input) 2 Mbit/s (cold point) 17 2 TX (RX) 2B Output (Input) 2 Mbit/s (hot point) 32 TX(RX) 2A Out put (input) 2 Mbit/s (cold point) 2 3 TX (RX) 3B Out put (Input) 2 Mbit/s (hot point) 18 TX(RX3A Output (input) 2 Mbit/s (cold point) 33 4 TX(RX) 4B Output (Input) 2 Mbit/s (hot point) 3 TX(RX) 4A Out put (input)
Summary of the content on the page No. 20
1 - INSTALLATION AND COMMISSIONING STM1 transmission port STM1 reception port ADR IC1 STATUS EOW AUX TR REC " " " EOW and AUX LED STATUS 81 Green Red 9 15 ON OFF Card in service 1 : NC ON ON Card in alarm 2 : TA 9 : TB OFF OFF Hardware default (fuse) 3 : TOF PA 10 : TOF PB OFF ON Card out of service 4 : RA 11 : RB Flashing Autotest default 5 : ROF PA 12 : ROF PB 6 : R64 A 13 : R64 B 7 : T64 A 14 : T64 B 8 : GND 15 : NC Version 1 STM1 transmission port STM1 reception port A