Fujitsu PRIMERGY RX200 S5 user manual

User manual for the device Fujitsu PRIMERGY RX200 S5

Device: Fujitsu PRIMERGY RX200 S5
Category: Laptop
Manufacturer: Fujitsu
Size: 4.62 MB
Added : 8/8/2014
Number of pages: 72
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Fujitsu PRIMERGY RX200 S5. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Fujitsu PRIMERGY RX200 S5.

For your convenience

If looking through the Fujitsu PRIMERGY RX200 S5 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Fujitsu PRIMERGY RX200 S5 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Fujitsu PRIMERGY RX200 S5 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Fujitsu PRIMERGY RX200 S5 User manual - Online PDF
Advertisement
« Page 1 of 72 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Fujitsu PRIMERGY RX200 S5 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Fujitsu PRIMERGY RX200 S5. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

PRIMERGY RX200 S5 Server
Options Guide
Edition April 2009

Summary of the content on the page No. 2

Comments… Suggestions… Corrections… The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs. Feel free to send us your comments by e-mail to manuals@ts.fujitsu.com. Certified documentation according to DIN EN ISO 9001:2000 To ensure a consistently high quality standard and user-friendliness, this documentation was created to meet the regulations of a quality management system which compl

Summary of the content on the page No. 3

Contents 1 Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.1 Concept and target groups . . . . . . . . . . . . . . . . . . . 5 1.2 Documentation overview . . . . . . . . . . . . . . . . . . . . 5 1.3 Expansions and conversions . . . . . . . . . . . . . . . . . . 7 1.4 Notational conventions . . . . . . . . . . . . . . . . . . . . . 9 2 Procedure . . . . . . .

Summary of the content on the page No. 4

Contents 7.1 Installing a SATA DVD drive . . . . . . . . . . . . . . . . . . . 38 8 HDD modules . . . . . . . . . . . . . . . . . . . . . . . . . . 41 9 Expansion cards and iBBU . . . . . . . . . . . . . . . . . . . 47 9.1 Installing an expansion card in riser cards . . . . . . . . . . 47 9.2 Installing a modular RAID controller . . . . . . . . . . . . . . 51 9.3 Installing an iBBU . . . . . . . . . .

Summary of the content on the page No. 5

1 Preface The PRIMERGY RX200 S5 server is an Intel-based server for mid-size networks and large companies. The server is suitable for use as a file server and also as an application, information or Internet server. Thanks to its highly developed hardware and software components, the PRIMERGY RX200 S5 server offers a high level of data security and availability. These components include hot-plug hard disk drive modules, redundant system fans and power supply units, the Server Management Serv

Summary of the content on the page No. 6

Documentation overview Preface – “Warranty” manual – “PRIMERGY ServerView Suite Local Service Concept - LSC” manual – “Returning used devices” manual – “Helpdesk” leaflet – Technical manual for the system board D2786 – “PRIMERGY RX200 S5 Server Operating Manual” – "D2786 BIOS Setup Utility for RX200 S5" manual I PRIMERGY manuals are available in PDF format on the PRIMERGY ServerView Suite DVD 2. The PRIMERGY ServerView Suite DVD 2 is part of the PRIMERGY ServerView Suite supplied with every se

Summary of the content on the page No. 7

Preface Expansions and conversions 1.3 Expansions and conversions Second processor The system board can be upgraded with a second processor. Only processors of the same type may be used on the system board. The second processor must have the same clock frequency as the first. Main memory expansion The system board supports up to 96 GB of main memory. 6 slots (2 banks with 3 channels each) are provided for each CPU for the main memory. Accessible drive In the version with a maximum of six HDD

Summary of the content on the page No. 8

Expansions and conversions Preface TPM A Trusted Platform Module (TPM) for safer storage of keys can be implemented as an option. This module enables programs from third party manufacturers to store key information (e.g. drive encryption using Windows Bitlocker Drive Encryption). The TPM is activated via the BIOS system (for more information, refer to the Fujitsu Technology Solutions BIOS manual). V CAUTION! – When using the TPM, note the program descriptions provided by the third party ma

Summary of the content on the page No. 9

Preface Notational conventions 1.4 Notational conventions The following notational conventions are used in this manual: Text in italics indicates commands or menu items. “Quotation marks” indicate names of chapters and terms that are being emphasized. Ê describes activities that must be performed in the order shown. V CAUTION! pay particular attention to texts marked with this symbol. Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data. I in

Summary of the content on the page No. 10

© cognitas. Gesellschft für Technik-Dokumentation mbH 2009 Pfad: W:\Anwendungsdaten\FCT\tim_local\work\PICHOL\OBJ_DOKU-4098-001.fm

Summary of the content on the page No. 11

2Procedure V CAUTION! ● The actions described in this manual should only be performed by technical specialists. ● Repairs to the device that do not relate to CSS failures must only be carried out by service personnel. Please note that unauthorized inter- ference with the system will void the warranty and exempt the manufacturer from all liability. ● Any failure to observe the guidelines in this manual, and any improper repairs could expose the user to risks (electric shock, energy hazards,

Summary of the content on the page No. 12

© cognitas. Gesellschft für Technik-Dokumentation mbH 2009 Pfad: W:\Anwendungsdaten\FCT\tim_local\work\PICHOL\OBJ_DOKU-4099-001.fm

Summary of the content on the page No. 13

3 Safety instructions I The following safety instructions are also provided in the manual “Safety notes and other important information”. This device meets the relevant safety regulations for IT equipment. If you have any questions about whether you can install the server in the intended environment, please contact your sales outlet or our customer service team. V CAUTION! ● The actions described in this manual should only be performed by technical specialists. ● Repairs to the device that

Summary of the content on the page No. 14

Safety instructions Before starting up V CAUTION! ● During installation and before operating the device, observe the instructions on environmental conditions for your device. ● If the device is brought in from a cold environment, condensation may form both inside and on the outside of the device. Wait until the device has acclimatized to room temperature and is absolutely dry before starting it up. Material damage may be caused to the device if this requirement is not observed. ● Transport

Summary of the content on the page No. 15

Safety instructions V CAUTION! ● Ensure that the power sockets on the device and the grounded shock- proof sockets are freely accessible. ● The On/Off button or the main power switch (if present) does not isolate the device from the mains power supply. To disconnect it completely from the mains power supply, unplug all network power plugs from the grounded shockproof sockets. ● Always connect the server and the attached peripherals to the same power circuit. Otherwise you run the risk of lo

Summary of the content on the page No. 16

Safety instructions V CAUTION! ● Proper operation of the system (in accordance with IEC 60950-1/ EN 60950-1) is only ensured if the casing is completely assembled and the rear covers for the installation slots have been fitted (electric shock, cooling, fire protection, interference suppression). ● Only install system expansions that satisfy the requirements and rules governing safety and electromagnetic compatibility and those relating to telecommunication terminals. If you install other ex

Summary of the content on the page No. 17

Safety instructions Working with CDs/DVDs and CD/DVD drives When working with devices with CD/DVD drives, these instructions must be followed. V CAUTION! ● Only use CDs/DVDs that are in perfect condition in your server's CD/DVD drive, in order to prevent data loss, equipment damage and injury. ● Check each CD/DVD for damage, cracks, breakages etc. before inserting it in the drive. Note that any additional labels applied may change the mechanical properties of a CD/DVD and cause imbalance. D

Summary of the content on the page No. 18

Safety instructions Modules with electrostatic-sensitive components Systems and components that might be damaged by electrostatic discharge (ESD) are marked with the following label: Figure 1: ESD label When you handle components fitted with ESDs, you must observe the following points under all circumstances: ● Remove the power plug before installing or removing components containing ESDs. ● You must always discharge yourself of static charges (e.g. by touching a grounded object) before work

Summary of the content on the page No. 19

4 Preparation V CAUTION! Follow the safety instructions in the chapter “Safety instructions” on page 13. 4.1 Pulling out/removing the server Ê Terminate all applications and shut down the server correctly. Ê If your operating system has not switched off the server, press the on/off button. Ê Pull all power connectors out of the power outlets. Ê Loosen the knurled screws on the sides and pull the server carefully out of the rack as far as it will go. I If the server is not easily accessible on

Summary of the content on the page No. 20

Opening the server Preparation 4.2 Opening the server You must remove the fan cover before removing the housing cover. Removing the fan cover 1 2 1 Figure 2: Opening the fan cover Ê Push the two green buttons (1) in the direction of the arrow and lift the fan cover upwards to remove it (2). Removing the housing cover Figure 3: Removing the housing cover Ê Use the two green locking levers (see circles) to unlock the housing cover. 20 Options Guide RX200 S5 © cognitas. Gesellschft für Technik-Do


Alternative user manuals
# User manual Category Download
1 Fujitsu 32-Bit Microcontroller MB9B500 Series User manual Laptop 21
2 Fujitsu A3110 User manual Laptop 33
3 Fujitsu 690TX User manual Laptop 9
4 Fujitsu A1010 User manual Laptop 5
5 Fujitsu A3040 User manual Laptop 10
6 Fujitsu A6025 User manual Laptop 8
7 Fujitsu A6010 User manual Laptop 7
8 Fujitsu A6110 User manual Laptop 12
9 Fujitsu A6020 User manual Laptop 9
10 Fujitsu A6210 User manual Laptop 4
11 Fujitsu AMILO Pa 2510-25P User manual Laptop 57
12 Fujitsu AH532 User manual Laptop 265
13 Fujitsu AMILO A1650G User manual Laptop 174
14 Fujitsu AMILO Pi 2550 User manual Laptop 342
15 Fujitsu B-2566 User manual Laptop 1
16 Sony CG-FX120K User manual Laptop 13
17 Sony FX120K User manual Laptop 8
18 Sony DG1 User manual Laptop 4
19 Sony BX540-BTO User manual Laptop 2
20 Sony FX150K User manual Laptop 2