Jabra IEC 1107 user manual

User manual for the device Jabra IEC 1107

Device: Jabra IEC 1107
Category: Battery Charger
Manufacturer: Jabra
Size: 0.07 MB
Added : 4/10/2014
Number of pages: 10
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Jabra IEC 1107. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Jabra IEC 1107.

For your convenience

If looking through the Jabra IEC 1107 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Jabra IEC 1107 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Jabra IEC 1107 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Jabra IEC 1107 User manual - Online PDF
Advertisement
« Page 1 of 10 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Jabra IEC 1107 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Jabra IEC 1107. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Blue Star C500 Static Single-phase Watt-hour Meter – IEC 61036 (1.0S)



IEC 61036
IEC 1107


C500 Single-Phase Watt-hour Meter



Product Description
Operating Instructions
Features and Technical Data
Maintenance Instructions
Diagrams and Figures












Nanjing Blue Star Electrical Meter Research Institute

181 Hanzhongmen Street
Nanjing 210036, China

International Sales Tel: 86-25-86504148
Fax: 86-25-86601945

www.bluestarmeters.com
sales@bluestarmet

Summary of the content on the page No. 2

Blue Star C500 Static Single-phase Watt-hour Meter – IEC 61036 (1.0S) TABLE OF CONTENTS 1. Features and Applications............................................................................................................3 1.1 Energy Metering..............................................................................................................3 1.2 1.2 Data displaying .........................................................................................................3 1.3 1

Summary of the content on the page No. 3

Blue Star C500 Static Single-phase Watt-hour Meter – IEC 61036 (1.0S) 1. Features and Applications Blue Star’s C500 watt-hour meter meets the IEC 61036 (class 1.0S) standard for energy meters. The main features of C500 include none physical adjustment components, digital signal processing, digital filters, digital error correction, digital calibration, immunity to temperature fluctuation, and excellent stability. Due to its 12 times overload multiplier, A0 can record energy usage of e

Summary of the content on the page No. 4

Blue Star C500 Static Single-phase Watt-hour Meter – IEC 61036 (1.0S) There are 2 modes after data processing unit powers up: 1. Running Mode: In this mode, B500 meter can perform TOU metering, demand calculating and load monitoring, and automatically display data at given time as programmed. 2. Programming mode: A0 will switch to this mode after holding reset button for 8 seconds. In this mode, LCD will display message “PRG”. It will only process energy counting, demand calculating and t

Summary of the content on the page No. 5

Blue Star C500 Static Single-phase Watt-hour Meter – IEC 61036 (1.0S) 2.2 Programming B500 can be programmed (namely parameter setting) through infrared port with handheld unit. 2.2.1 Password Password is needed to program B500, reading does not need password. Password can not be modified. Password is set as “666666”, please keep it at the safety place. Page 5 1/26/2005 Rev 1.0.01

Summary of the content on the page No. 6

Blue Star C500 Static Single-phase Watt-hour Meter – IEC 61036 (1.0S) 3. Specifications and technical data 1.1 Specifications 1.2 Technical data 1.2.1 Power supply Power Current Power Meter type consumption (mA) (W) (VA) 220V <5 <1 <0.7 (transformer) 110V <4 <0.8 <0.5 (transformer) 4. Use, transportation and storage conditions Same requirements as indoor meters. The number of piling layers should not exceed five in original package. Moisture absorbent must b

Summary of the content on the page No. 7

Blue Star C500 Static Single-phase Watt-hour Meter – IEC 61036 (1.0S) Appendix A: Warning and Error Information ERR 2 Error Info 0000 0001 Clock ‘s Oscillator Error 0000 0010 Read/Write Clock Error 0000 0100 Read/Write EEPROM Error 0000 1000 Read /Write Cs5460A Error 0001 0000 CPU Program Error 0010 0000 reserved 0100 0000 Low Battery Voltage 1000 0000 SPI Read or Write Error ERR 1 Warning Info 0000 0001 Over Voltage 0000 0010 Under Voltage 0000 0100 Pha

Summary of the content on the page No. 8

Blue Star C500 Static Single-phase Watt-hour Meter – IEC 61036 (1.0S) Appendix B: Connect Figure 3 Phase 4 Wire Direct connection Connection through current transformer Connection through current transformer and voltage transformer Page 8 1/26/2005 Rev 1.0.01

Summary of the content on the page No. 9

Blue Star C500 Static Single-phase Watt-hour Meter – IEC 61036 (1.0S) 3 Phase 3 Wire Direct connection Connection through current transformer Connection through current transformer and voltage transformer Output Define Page 9 1/26/2005 Rev 1.0.01

Summary of the content on the page No. 10

Blue Star C500 Static Single-phase Watt-hour Meter – IEC 61036 (1.0S) NO.1 Pulse Output : Active import energy NO.2 Pulse Output : Active export energy NO.3 Pulse Output : Reactive import energy NO.4 Pulse Output : Reactive export energy RXD : PC send data to meter TXD : Meter send data to PC Page 10 1/26/2005 Rev 1.0.01


Alternative user manuals
# User manual Category Download
1 Jabra IEC 61036 User manual Battery Charger 3
2 Craftsman 950138 User manual Battery Charger 1
3 Sony AC-L200 User manual Battery Charger 23
4 Sony AC VQ800 User manual Battery Charger 11
5 Sony AC SQ950D User manual Battery Charger 9
6 Sony AC V700A User manual Battery Charger 11
7 Sony AC ADAPTOR AC-V700 User manual Battery Charger 58
8 Sony AC-VQV10 User manual Battery Charger 19
9 Sony AC V17 User manual Battery Charger 4
10 Sony AC VQ11 User manual Battery Charger 4
11 Sony AC VQP10 User manual Battery Charger 3
12 Sony BC VC10 User manual Battery Charger 4
13 Sony BC M150 User manual Battery Charger 56
14 Sony BC-TRG User manual Battery Charger 10
15 Sony BC-CSQ2 User manual Battery Charger 40