Aiphone JK-DVF-AC user manual

User manual for the device Aiphone JK-DVF-AC

Device: Aiphone JK-DVF-AC
Category: Intercom System
Manufacturer: Aiphone
Size: 5.07 MB
Added : 10/29/2013
Number of pages: 13
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Aiphone JK-DVF-AC. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Aiphone JK-DVF-AC.

For your convenience

If looking through the Aiphone JK-DVF-AC user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Aiphone JK-DVF-AC on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Aiphone JK-DVF-AC to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Aiphone JK-DVF-AC User manual - Online PDF
Advertisement
« Page 1 of 13 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Aiphone JK-DVF-AC but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Aiphone JK-DVF-AC. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


83799600 A P1009YZ
JK-DVF-AC
Vandal-resistant Color Video Door Station
with Access Control Keypad
Platine vidéo couleur résistante au vandalisme
avec clavier à codes rétro-éclairé
Antivandalisme deurpost met kleurencamera en
ingebouwd codeklavier
JK-DVF-AC
INSTALLATION & OPERATION MANUAL
MANUEL D’INSTALLATION ET D’UTILISATION
INSTALLATIE & GEBRUIKSHANDLEIDING
JK-DVF-AC_ENG.indd 1 2009/10/05 21:18:28

Summary of the content on the page No. 2

RECORD OF SETTINGS AND REGISTRATION DETAILS FOR ACCESS CONTROL (Please make sure to write down your settings below.) AIDE MEMOIRE DES PROGRAMMATIONS ENREGISTREES POUR LE CLAVIER (Faire en sorte de bien noter vos réglages ci-dessous.) LIJST MET GEPROGRAMMEERDE INSTELLINGEN EN CODES VOOR CODEKLAVIER (Zorg ervoor uw instellingen hieronder op te schrijven.) External output setting Master code Code maître Paramétrage de sortie externe ON OFF Hoofdcode AAN UIT Activering Alarmuitgang Key illuminat

Summary of the content on the page No. 3

English Français Nederlands English T h a n k y o u f o r s e l e c t i n g A i p h o n e f o r y o u r c o m m u n i c a t i o n a n d s e c u r i t y n e e d s . P l e a s e r e a d t h i s m a n u a l c a r e f u l l y before installation, and keep it in a safe place for future reference. * Refer to the “INSTALLATION & OPERATION MANUAL” for the JK-1MED or JK-1MD for complete information regarding this system. PRECAUTIONS General Prohibitions Prohibition to

Summary of the content on the page No. 4

PACKAGE CONTENTS Transparent Door station with Flush mount back box Special screwdriver Installation & Operation manual nameplate (x2) MOUNTING Mounting locations "Do not install this unit in any of the following locations where lighting or the ambient environment could impact the display on the video monitor due to the characteristics of the door station's camera." a Locations subject to b Under street lights or door c Other locations subject to strong direct sunlight lights lighting or bac

Summary of the content on the page No. 5

English Français Nederlands Mounting 1. Detach the door station from the flush mount back box by removing the screws with the special screwdriver that is supplied with the unit. 2. Attach the flush mount back box to the wall. 3. Route wiring through the flush mount back box and connect wires to the door station. * See page 5 and 6 for details on wiring and connections. 4. Attach the door station to the flush mount back box. * Be sure to use the original screws to reattach the door stati

Summary of the content on the page No. 6

WIRING AND CONNECTIONS Outline of connections and wiring distance Wiring distance Power supply Diameter Distance A - 0.65 mm (22 A WG) 50m (165') - 1.0 mm (18 A WG) 100m (330') A B 12 - 18V AC or DC 0.65 - 1.0 mm 100m (330') or less (22 - 18 A WG) Master station A1 18 - 24V AC or DC 0.65 - 1.0 mm 300m (980') (22 - 18 A WG) A2 or C - 0.65 - 1.0 mm 300m (980') A1 A2 (22 - 18 A WG) 2 D - The connection distance will depend on JK-1MED JK-1MD the specifications of the electric door strike, rel

Summary of the content on the page No. 7

English Français Nederlands Connection examples n Connection of Relay 1 only JK-1MED/1MD or A1 A2 L L 2 JK-1MED JK-1MD NP JK-DVF-AC 2 NP A1 A2 Example of electric door Example of automatic Example of electromagnetic strike connection (N/O) gate connection (N/O) door lock connection (N/C) V PB1 PB2 C T NO1 C1 NC1 NO2 C2 NC2 NO1 C1 NC1 N V NO1 C1 NC1 NO2 C Electromagnetic Electric door strike door lock 2 NP 2 2 2 NP NP NP 2 or or NP PS Automatic gate Power supply Request to exit/entry button AC t

Summary of the content on the page No. 8

FUNCTIONS/SETTING UP FOR ACCESS CONTROL This section explains the settings of each function, including the master code for management, the user code for unlocking, the buzzer and the LEDs. About the setting mode: Enter master code twice to switch to the setting mode, and enter the following setting code to perform the settings for the desired function. After settings have been made, enter the following setting codes to continue the setting operation. Press to exit the setting mode. Setting

Summary of the content on the page No. 9

English Français Nederlands The result of each operation is indicated by the Orange (L) Green (R) lighting up of the LED indicators located just above the keys, and by the sounding of the buzzer. (orange) (green) Illumination Blinking Input the master code twice. Bleep, Bleep (Default: ) Setting the code length Setting the master code Setting the code (Default: 4 digits) (Default:1234) group 1 group 2 00 - 59 60 - 99 Input

Summary of the content on the page No. 10

(orange) (green) (orange) (green) Illumination Blinking Illumination Blinking Input the master code twice. Input the master code twice. Bleep, Bleep Bleep, Bleep (Default : ) (Default : ) Auto-relock Lockout Timer-linked unlocking setting Operation sound settings Setting the key illumination time Setting the relay output time External output se

Summary of the content on the page No. 11

English Français Nederlands (orange) (green) Illumination Blinking Input the master code twice. Bleep, Bleep (Default : ) Auto-relock Lockout Timer-linked unlocking setting Operation sound settings (Anti-tailgate) (Default: OFF) (Default: relay 1, OFF) (Default: ON) (Default: OFF) Input the setting code. Input the setting code. Input the setting code. Input the setting code. Illumination Blinking Illumination Bli

Summary of the content on the page No. 12

OPERATION OF ACCESS CONTROL * Also refer to the “INSTALLATION & OPERATION • When the "Lockout" function has been set, the release MANUAL” for the master station (JK-1MED or JK- function is locked and the input operation is disabled for 1MD) connected to this unit regarding the operation the specified time (10 - 99 seconds) if invalid codes are of the video door station. input a set number of times (10 - 99 times). (Reference: "Lockout".) During this time, the key illumination will A. Unlo

Summary of the content on the page No. 13

English Français Nederlands SPECIFICATIONS General Access control keypad • Dimen sions: • Power supply: 12 - 24V AC Door station: 295(H) × 144(W) × 8(D) (recess: 30) mm 12 - 24V DC H 1 1-5/8” x W 5-3/4” x D 5/16”, recess 1-3/16” • Power consumption: DC: Max. 70mA Flush mount back box: 263(H) × 1 14(W) × 45(D) mm AC: Max. 100mA H 10-3/8” x W 4-1/2” x D 1-3/4” • Number of relay circuits: 2 • W eigh t: • Relay contact: N/O, N/C D


Alternative user manuals
# User manual Category Download
1 Aiphone AT-306 User manual Intercom System 44
2 Aiphone AP-10M User manual Intercom System 11
3 Aiphone 0311 A OI User manual Intercom System 4
4 Aiphone AP-5M User manual Intercom System 10
5 Aiphone ACCESS SENTRY LEM-1DLS User manual Intercom System 6
6 Aiphone 0311 A OI User manual Intercom System 6
7 Aiphone A83090 User manual Intercom System 3
8 Aiphone AX-A User manual Intercom System 2
9 Aiphone AN-8540DS User manual Intercom System 0
10 Aiphone DA-2DS User manual Intercom System 3
11 Aiphone DB User manual Intercom System 4
12 Aiphone GF-1D User manual Intercom System 108
13 Aiphone GF-2B User manual Intercom System 17
14 Aiphone GF-10K User manual Intercom System 65
15 Aiphone DA-4DS User manual Intercom System 1
16 3M 2475 User manual Intercom System 5
17 3M C5000 User manual Intercom System 1
18 3M 478DA (D-15) User manual Intercom System 4
19 3M D-2400 User manual Intercom System 1
20 3M HEADSET C1060 User manual Intercom System 3