Summary of the content on the page No. 1
INSTALLATION INSTRUCTIONS
PP-FCTA-QL
Ceiling Adapter
EUROPE
NORTH AMERICA
3130 East Miraloma Avenue
Swallow House,
Anaheim, CA 92806 USA
Shilton Industrial Estate,
USA and Canada –
Shilton, Coventry, England CV79JY
Phone: 800-368-9700
Phone: +44 (0) 2476 614700
Fax: 800-832-4888
Fax: +44 (0) 2476 614710
Other Locations – Phone: (001)-714-632-7100; Fax: (001)-714-632-1044
©Premier Mounts 2008
9533-030-001-01
Summary of the content on the page No. 2
PP-FCTA-QL Table of Contents Warning Statements 2 Parts List 3 Installation Tools 3 Plate Assembly 4 Securing the Plate 5 Electrical Box Installation 5 Ceiling Anchoring 7 Cable Lock Operation 8 Securing Pipe to PP-FCTA-QL 10 Technical Specifi cations 10 Warranty 11 Warning Statements PRIOR TO THE INSTALLATION OF THIS PRODUCT, THE INSTALLATION INSTRUCTIONS SHOULD BE READ AND COMPLETELY UNDERSTOO
Summary of the content on the page No. 3
PP-FCTA-QL Parts List This ceiling adapter comes packaged with installation hardware and components. Make sure that none of these parts are missing and/or damaged before beginning installation. If there are parts missing and/or damaged, please stop the installation and contact Premier Mounts (800-368-9700). 1/4-20 Wing Nuts Ceiling Adapter (Qty 4) (Qty 1) M5 x 16 Phillips Head Screws (Qty 5) Quick Locks (Qty 4) ¼” x 3” Eye Lag Screws (Qty 4) 1/16” Braided Cable (Qty 4 Strands) ¼” x 3” Concre
Summary of the content on the page No. 4
PP-FCTA-QL Plate Assembly Read all cautions and warnings before continuing. 1/4-20 Wing Nuts Step 1. Assemble the plate. Step 2. Place the lower adapter plate with the threaded studs on it up through mounting plate. Upper Adapter Step 3. The threaded studs will align with the Plate adjustable slide on the mount. Step 4. Once the two pieces are together, align the mounting holes on the upper adapter plate with the threaded shafts of the lower adapter plate. Step 5. Place the three unit
Summary of the content on the page No. 5
PP-FCTA-QL Securing the Plate T-Bar Frame Rails Adjust and Tighten Wing Nut M5 x 16mm Set Screw Tiles Step 1. Position and slide the adapter plate to the hole and secure the ceiling plate to the rails by tightening the four (4) M5 x 16mm Phillips head screws. Step 2. Center the stud plate to the hole and secure the plate by tightening the four wing nuts.. Electrical Box Installation Electrical installation should be done in accordance to local codes and regulations. Step 1. Cut the tile whe
Summary of the content on the page No. 6
PP-FCTA-QL The electrical cut-outs allow for both single and square electrical box installations. Electrical Box Page 6 Installation Instructions
Summary of the content on the page No. 7
PP-FCTA-QL Ceiling Anchoring THE PP-FCTA-QL MUST SECURED USING THE SUPPLIED QUICK LOCKS AND BRAIDED CABLES. Truss Concrete Wood Truss Concrete Wood Joist Eye Lag Hole Loop Eye Lag Hole Loop Braided Cable Braided Cable Concrete Truss ceiling Wood joist Step 1. Determine the mounting Step 1. Loop the braided cable Step 1. Secure the four (4) ¼” eye location. around the truss. lag screws to the wood joist Step 2. Use a 1/4” masonry drill bit Step 2. Run the open end through in t
Summary of the content on the page No. 8
PP-FCTA-QL Quick Lock Operation Feed braided cable into the Quick Lock (see Cable Output directional input arrows). To release the braided cable, Cable Input slide the release pin to disengage. Directional Input Arrows Release Pin Directional Input Arrows Braided Braided Braided Braided Cable Cable Cable Cable 6” Excess Directional Input Directional Input Directional Input Arrows Arrows Arrows Release Pin Release Pin Release Pin Release Pin Mounting Hole Mounting Hole Mounting Hole Page 8
Summary of the content on the page No. 9
PP-FCTA-QL Step 1. Thread each braided cable through the Quick Lock, the mounting hole in the corner of ceiling mount, and then completely through the opposite side of the Quick Lock to secure. To relieve tension on the braided cable, slide the release pin on the Quick Lock. Step 2. Adjust the braided cable tension. but do not overtighten. Step 3. When adjusting the tension of the weight-bearing side of the Quick Lock, the cable must be pulled through the Quick Lock until the desired tensio
Summary of the content on the page No. 10
PP-FCTA-QL Securing Pipe to the PP-FCTA-QL Step 1. Secure the 1½” (NPT) pipe to the ceiling plate and tighten by using one (1) M5 x 16 Phillips head screw (supplied) to the plate. The M5 x 16 Phillip head screw must be used to stabilize the 1½” (NPT) pipe. 1-1/2” Pipe M5 x 16mm Set Screw 1-1/2” Pipe Ceiling Plate Assembly Tiles T-Bar Frame Rails Technical Specifi cations All measurements are in inches [mm]. Page 10 Installation Instructions
Summary of the content on the page No. 11
PP-FCTA-QL Warranty PREMIER MOUNTS LIMITED LIFETIME WARRANTY What and Who is Covered by this Limited Warranty and for How Long Premier Mounts warrants this product to be free from defects in material and workmanship for the lifetime of the original owner of this product. The limited warranty is valid only for the original purchaser of the product. What Premier Mounts Will Do At the sole option of Premier Mounts, Premier Mounts will repair or replace any product or product part that is defecti