NuTone Humidity Sensing Recessed Fan/Fluorescent Light 744SFLNT user manual

User manual for the device NuTone Humidity Sensing Recessed Fan/Fluorescent Light 744SFLNT

Device: NuTone Humidity Sensing Recessed Fan/Fluorescent Light 744SFLNT
Category: Indoor Furnishings
Manufacturer: NuTone
Size: 1.75 MB
Added : 3/8/2013
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for NuTone Humidity Sensing Recessed Fan/Fluorescent Light 744SFLNT. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with NuTone Humidity Sensing Recessed Fan/Fluorescent Light 744SFLNT.

For your convenience

If looking through the NuTone Humidity Sensing Recessed Fan/Fluorescent Light 744SFLNT user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual NuTone Humidity Sensing Recessed Fan/Fluorescent Light 744SFLNT on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual NuTone Humidity Sensing Recessed Fan/Fluorescent Light 744SFLNT to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
NuTone Humidity Sensing Recessed Fan/Fluorescent Light 744SFLNT User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual NuTone Humidity Sensing Recessed Fan/Fluorescent Light 744SFLNT but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to NuTone Humidity Sensing Recessed Fan/Fluorescent Light 744SFLNT. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

MODEL 744SFLNT
Page 1
HUMIDITY SENSING RECESSED
FLUORESCENT FAN / LIGHT
READ AND SAVE THESE INSTRUCTIONS
WARNING OPERATION
TIMER ADJUSTMENT
The light, fan and humidity control can be operated
TO REDUCE THE RISK OF FIRE, ELECTRIC
together or independently using multi-function switch This humidity-sensing fan has a “TIMER” . It is user-
SHOCK, OR INJURY TO PERSONS, OBSERVE THE
wall controls. adjustable from 5 to 60 minutes and is factory-set
FOLLOWING:
at 20 minutes. The “TIMER” controls

Summary of the content on the page No. 2

MODEL 744SFLNT Page 2 PLAN THE INSTALLATION INSTALLATION POWER 4" ROUND CARDBOARD PROTECTOR CABLE DAMPER/DUCT CONNECTOR & 4” ROUND HOUSING DUCTWORK CEILING MOUNTING JOIST BRACKET FINISHED CEILING TRIM RING / BAFFLE 1. Install mounting brackets. Typical Installation Slide the adjustable mounting brackets into the bracket channels The unit can be installed anywhere between ceiling joists using mounting on the housing. brackets provided. Install in a flat ceiling only. Bend the tabs on the card

Summary of the content on the page No. 3

MODEL 744SFLNT Page 3 WIRING OPTION #1 – Allows fan to operate in automatic mode or manual mode (for odor control) by cycling ON/OFF switch. MODEL 68W 2-FUNCTION CONTROL (PURCHASE SEPARATELY) LIGHT RED BLU (ON/OFF) LIGHT COM ORG BLK WHT FAN FAN BLK BRN (AUTO/OFF) GRD WHT HUMIDITY CONTROL BLK 120 WHT 4. Hang and secure housing. VAC GRD GRD LINE WHT WHT WHT IN Hang unit from nails. Check to make sure that there will be a 1/8” SWITCH UNIT gap between bottom of housing and ceiling mater

Summary of the content on the page No. 4

MODEL 744SFLNT Page 4 SERVICE PARTS 1 2 Humidity Control Assembly 4 must be removed to 3 service these parts. 5 6 9 15 7 10 8 11 13 9. Plug in wiring. Plug wiring into the proper receptacles. 12 14 TRIM RING / BAFFLE KEY NO. PART NO. DESCRIPTION 1 97014185 Damper / Duct Connector 2 97016382 Housing Assembly 3 98003036 Mounting Bracket (4 req.) 4 98005512 Wiring Adaptor Plate 5 99524804 Blower Wheel * 6 99524805 Motor Bracket / Venturi * 7 99080557 Motor * 97016454 Motor / Motor Brack

Summary of the content on the page No. 5

MODÈLE 744SFLNT Page 5 LAMPE FLUORESCENTE / VENTILATEUR ENCASTRÉ À DÉTECTEUR D’HUMIDITÉ LIRE CES DIRECTIVES ET LES CONSERVER AVERTISSEMENT FONCTIONNEMENT La lumière, le ventilateur et le contrôle d’humidité peuvent 5. Remettez l’ampoule. OBSERVEZ LES DIRECTIVES CI-DESSOUS AFIN être commandés ensemble ou séparément à l’aide de DE RÉDUIRE LES RISQUES D’INCENDIE, DE CHOC 6. Rétablissez le courant et vérifiez le fonctionnement commutateurs muraux multifonction. ÉLECTRIQUE OU DE BLESSURES CORP

Summary of the content on the page No. 6

MODÈLE 744SFLNT Page 6 PLANIFICATION DE L’INSTALLATION INSTALLATION CLAPET / RACCORD PROTECTEUR EN CARTON DE CONDUIT ROND DE FIL D'ALIMENTATION 10,2 CM (4 PO) ET CONDUIT ROND DE 10,2 CM (4 PO) BOÎTIER SOLIVE DU BRIDE DE PLAFOND MONTAGE PLAFOND FINI ANNEAU DE GARNITURE / DÉFLECTEUR 1. Installez les brides de montage. Installation type Glissez les brides de montage réglables dans les rainures L’appareil peut être installé partout entre les solives du plafond à l’aide du boîtier. des brides

Summary of the content on the page No. 7

MODÈLE 744SFLNT Page 7 OPTION DE CåBLAGE N¡ 1 Ð Permet au ventilateur de fonctionner en mode automatique ou manuel (pour le contrôle des odeurs) en tournant le commutateur MARCHE / ARRÊT. MODéLE 68W COMMANDE Ë 2 FONCTIONS (VENDUE SƒPARƒMENT) ƒCLAIRAGE ROUGE BLEU (MARCHE / ƒCLAIRAGE ARRæT) COM ORG NOIR VENTI- BLANC LATEUR VENTILATEUR (AUTO / ARRæT) NOIR BRUN TERRE BLANC CONTRïLE DÕHUMIDITƒ NOIR ALI- MENTA- TERRE ORG BLANC 4. Suspendez et fixez le boîtier. TION 120 BLANC BLANC BLANC VCA Sus

Summary of the content on the page No. 8

MODÈLE 744SFLNT Page 8 PIÈCES DE RECHANGE 1 2 L’ensemble du contrôle 4 d’humidité doit être enlevé pour 3 accéder à ces pièces. 5 6 9 15 7 10 8 11 13 9. Branchez les fils. Branchez les fils dans les prises appropriées. 12 14 ANNEAU DE GARNITURE / DÉFLECTEUR REPÈRE N° DE PIÈCE DESCRIPTION 1 97014185 Clapet / raccord de conduit 2 97016382 Ensemble de boîtier 3 98003036 Bride de montage (4 req.) 4 98005512 Plaque d’adaptateur de câblage 5 99524804 Roue à ailettes* 6 99524805 Support de mot

Summary of the content on the page No. 9

MODELO 744SFLNT Página 9 VENTILADOR EMPOTRADO CON SENSOR DE HUMEDAD Y LÁMPARA FLUORESCENTE LEA Y CONSERVE ESTAS INSTRUCCIONES ADVERTENCIA FUNCIONAMIENTO La lámpara, el ventilador y el control de humedad deben 5. Reinstale la bombilla. PARA REDUCIR EL RIESGO DE INCENDIOS, funcionar en conjunto o individualmente, usando controles DESCARGAS ELÉCTRICAS O LESIONES PERSONALES, 6. Suministre energía y revise el funcionamiento de pared en un interruptor de funciones múltiples. OBSERVE LAS SIGUIEN

Summary of the content on the page No. 10

MODELO 744SFLNT Página 10 PLANEACIÓN DE LA INSTALACIÓN INSTALACIÓN CABLE CONECTOR DEL REGULADOR PROTECTOR DE CARTÓN DE TIRO/CONDUCTO REDONDO ELÉCTRICO DE 4 PULG. Y CONDUCTO REDONDO DE 4 PULG. CUBIERTA VIGUETA SOPORTE DE TECHO DE MONTAJE CIELO RASO ACABADO ANILLO/DEFLECTOR 1. Instale los soportes de montaje. Instalación típica Deslice los soportes de montaje ajustables en los canales del soporte Esta unidad se puede instalar en cualquier lugar entre las vigas del de la cubierta. cielo raso

Summary of the content on the page No. 11

MODELO 744SFLNT Página 11 OPCIîN DE CONEXIîN N.¼ 1: Permite que el ventilador funcione en modo automático o en modo manual (para el control del olor) al ciclar el interruptor de ENCENDIDO/APAGADO. MODELO 68W CONTROL DE 2 FUNCIONES (SE COMPRA POR SEPARADO) LçMPARA AZUL ROJO (ENCENDIDO/ LUZ APAGADO) COM NARANJA NEGRO VENTI- BLANCO LADOR VENTILADOR (AUTO/ BLEU CAFƒ TERRE APAGADO) BLANCO CONTROL DE HUMEDAD NEGRO LêNEA 4. Cuelgue la unidad y asegúrela. DE EN- BLANCO TIERRA TIERRA TRADA DE 120 B

Summary of the content on the page No. 12

MODELO 744SFLNT Página 12 PIEZAS DE SERVICIO 1 2 Debe quitar el conjunto de 4 control de humedad para dar 3 servicio a estas piezas. 5 6 9 15 7 10 8 11 13 9. Conecte el cableado. Enchufe las conexiones en los receptáculos adecuados. 12 14 ANILLO/DEFLECTOR CLAVE N.º PIEZA N.º DESCRIPCIÓN 1 97014185 Conector del regulador de tiro/conducto 2 97016382 Conjunto de la cubierta 3 98003036 Soporte de montaje (se requieren 4) 4 98005512 Placa del adaptador de cableado 5 99524804 Rueda del soplador


Alternative user manuals
# User manual Category Download
1 NuTone 62BK244TGK(X) User manual Indoor Furnishings 0
2 NuTone DECORATIVE 754SNNT User manual Indoor Furnishings 0
3 NuTone 62BK244TMP User manual Indoor Furnishings 0
4 NuTone 62BK244CCY(X) User manual Indoor Furnishings 0
5 NuTone Humidity Sensing Recessed Fan/Floursecent Light 744FLNT User manual Indoor Furnishings 0
6 NuTone 62BK244CMP User manual Indoor Furnishings 0
7 NuTone 62BK244CCN(X) User manual Indoor Furnishings 0
8 NuTone DECORATIVE 754RBNT User manual Indoor Furnishings 0
9 NuTone 62BK244TCY(X) User manual Indoor Furnishings 0
10 NuTone QTXEN080FLT User manual Indoor Furnishings 0
11 NuTone QTXEN110FLT User manual Indoor Furnishings 0
12 NuTone 62BK244TBK(X) User manual Indoor Furnishings 0
13 NuTone HUMIDITY SENSING FAN/LIGHT/NIGHTLIGHT QTXEN110SFLT User manual Indoor Furnishings 0
14 NuTone QTXEN150FLT User manual Indoor Furnishings 1
15 NuTone 62BK244CBK(X) User manual Indoor Furnishings 0
16 Sony User manual Indoor Furnishings 1
17 Sony XL-2000K User manual Indoor Furnishings 1
18 Sony SU-32FS2 User manual Indoor Furnishings 3
19 Sony PSS-610 User manual Indoor Furnishings 10
20 Sony HVL-LBP User manual Indoor Furnishings 8