Hach SIGMA 900 user manual

User manual for the device Hach SIGMA 900

Device: Hach SIGMA 900
Category: Indoor Furnishings
Manufacturer: Hach
Size: 1.3 MB
Added : 4/18/2013
Number of pages: 52
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Hach SIGMA 900. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Hach SIGMA 900.

For your convenience

If looking through the Hach SIGMA 900 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Hach SIGMA 900 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Hach SIGMA 900 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Hach SIGMA 900 User manual - Online PDF
Advertisement
« Page 1 of 52 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Hach SIGMA 900 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Hach SIGMA 900. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Catalog Number 8544
Sigma 900 Composite Sampler
INSTRUMENT MANUAL
© Hach Company, 2003. All rights reserved. Printed in the U.S.A. eac 07/03 2ed

Summary of the content on the page No. 2

Visit http: //www.hach.com

Summary of the content on the page No. 3

Table of Contents Section 1 Specifications..................................................................................................................................... 5 Section 2 General Information.......................................................................................................................... 7 2.1 Instrument Description........................................................................................................................................ 7 2.2

Summary of the content on the page No. 4

Table of Contents Section 5 Maintenance ..................................................................................................................................... 33 5.1 Cleaning the Sampler ....................................................................................................................................... 33 5.1.1 Cleaning the Sampler Housing................................................................................................................ 33 5.1.2 Cle

Summary of the content on the page No. 5

Section 1 Specifications Specifications are subject to change without notice. Height: 34 cm (13.5 in.), Width 28 cm (11 in.), Depth 20.3 cm (8 in.) without wall Controller Dimensions bracket, 33 cm (13 in.) deep with wall bracket High impact injection molded ABS: submersible, watertight, dust tight, corrosion Pump/Controller Housing and ice resistant; NEMA 4X, 6 High speed peristaltic, dual roller, with 9.53 ID x 15.9 mm OD (3/8 in. x 5/8 in.) Sample Pump medical grade silicone rubber pump tu

Summary of the content on the page No. 6

Visit http: //www.hach.com

Summary of the content on the page No. 7

Section 2 General Information 2.1 Instrument Description The instrument is designed to automatically collect and preserve samples from a liquid source. The sampler is suitable for collection of conventional and toxic pollutants and suspended solids. The sampler collects samples on either a timed cycle basis, or in proportion to flow when used in conjunction with a flow meter (flow meter connected to the auxiliary connector). In the timed cycle mode, the interval between samples is controlle

Summary of the content on the page No. 8

Section 2 Figure 1 Interface Connectors 1 2 1. 12 V 2. Auxiliary dc 2.3 Front Panel The front panel consists of the keypad, liquid crystal display, and the internal case humidity indicator (Figure 2). 2.3.1 Keypad and Display The sampler controller is equipped with a 24 character alphanumeric liquid crystal display which automatically steps the user through the program settings. 2.3.2 Humidity Indicator The internal case humidity indicator (Cat. No. 2660) turns pink when the internal c

Summary of the content on the page No. 9

Section 2 Figure 2 900 Composite Sampler 1 2 7 6 3 4 5 1. Function Key 5. Power On Indicator LED 2. Peristaltic Pump 6. Desiccant Indicator 3. Peristaltic Pump Tubing 7. 24-character Alphanumeric Liquid Crystal Display 4. Tubing Clamp 2.4 Safety Information Please read this entire manual before unpacking, setting up, or operating this instrument. Pay particular attention to all danger and caution statements. Failure to do so could result in serious injury to the operator or damage to the equi

Summary of the content on the page No. 10

Section 2 2.4.1 Use of Hazard Information If multiple hazards exist, this manual will use the signal word (Danger, Caution, Note) corresponding to the greatest hazard. DANGER Indicates a potentially or imminently hazardous situation which, if not avoided, could result in death or serious injury. CAUTION Indicates a potentially hazardous situation that may result in minor or moderate injury. NOTE Information that requires special emphasis. 2.4.2 Precautionary Labels Read all labels and tags

Summary of the content on the page No. 11

Section 2 DANGER Bien que certains produits Hach soient conçus et certifiés pour être installés dans des endroits dangereux tels que définis par le National Electric Code, de nombreux produits Hach ne conviennent pas pour de tels endroits. Il relève de la responsabilité des personnes qui placent les produits dans des endroits dangereux de déterminer s'ils sont adaptés à cet environnement. En outre, à des fins de sécurité, le placement de machines dans des endroits dangereux doit s'effectue

Summary of the content on the page No. 12

Section 2 2.4.5 Definition of Confined Space A Confined Space is any location or enclosure that presents or has the immediate potential to present one or more of the following conditions:  An atmosphere with less than 19.5% or greater than 23.5% oxygen and/or more than 10 ppm Hydrogen Sulfide (H S) 2  An atmosphere that may be flammable or explosive due to gases, vapors, mists, dusts, or fibers  Toxic materials which upon contact or inhalation, could result in injury, impairment of health

Summary of the content on the page No. 13

Section 3 Installation DANGER Only qualified personnel should conduct the installation tasks described in this section of the manual 3.1 Unpacking the Instrument Remove the sampler from the shipping carton and inspect it for any damage. Contact Hach Customer Service at 1-800-227-4224 if any items are missing or damaged. 3.2 Selecting the Installation Site The sampler is completely self-contained and may be located indoors or outdoors without protection, between 0 to 50 °C (32 to 120 °F). Fo

Summary of the content on the page No. 14

Section 3 Figure 4 Wall Mount Bracket 3.3 Mounting the Sampler Attach the wall mount bracket to a stable panel or wall (Figure 4). Mount the bracket so the sample display and keypad are easily accessible. Mount the sampler to the wall bracket using the four screws provided. 3.4 Attaching the Intake Line 3.4.1 Vinyl Intake Tubing 1. Push one end of the clear flexible PVC (vinyl) tube to the tapered end of the intake strainer, until the tube is within 0.635 cm (¼ in.) of the solid white Tefl

Summary of the content on the page No. 15

Section 3 4. Slide the tubing clamp over the silicone tubing until it is over the stainless steel fitting on the liquid sensor. Tighten to secure. 5. Repeat the procedure for the intake strainer. 3.5 Setting Up the Intake Line and Strainer For each sampling location, the intake line should be as short as practical, and be free of any sharp bends, coils, or loops. Install the intake line with a downward slope from the sampler to the sample source because:  This will assure the complete draina

Summary of the content on the page No. 16

Section 3 Figure 5 Full Bottle Shut-off 1 2 1. Sample Tubing 2. Full Bottle Shut-off 3.8 Power Connections The sampler controller operated on 12 V dc which is supplied by an optional ac/dc power converter and/or battery. Note: Make sure both rubber hold- The power supply (or battery) is placed in the compartment located directly downs are attached to the clips at behind the controller. Pull the rubber hold-downs up and over the clips at each each end of the power supply. end of the power su

Summary of the content on the page No. 17

Section 3  Before performing any maintenance, disconnect the sampler from the power source.  Do not attempt to make any connection or otherwise handle the electrical components of the sampler when connected to ac line power if the immediate area is wet, or if hands or clothing are wet.  If the circuit breaker or fuse in the ac power source is tripped, determine the cause before restoring power to the sampler.  Make sure the power circuit is grounded and protected with a Ground Fault Int

Summary of the content on the page No. 18

Section 3 Table 2 Auxiliary Pin Assignments Pin Signal Description Wire Color Purpose Rating This line is held at 5 V dc inside the sampler. When shorted to ground (Pin B), a signal is sent to the microprocessor inside the sampler causing it to “wake up” and begin or resume the sampling program. It can be used in conjunction with a simple level float switch 24 V dc Liquid Level to actuate the sampler when liquid id present or to take over after a (max) at D Actuator/Auxiliary Black second

Summary of the content on the page No. 19

Section 3 Figure 6 4–20 mA Interface and Pulse Duration Input (+) To Auxillary Connector (-) For details on programming the sampler for flow proportional operation, refer to SECTION. Splitter Interface This splitter interface (Cat. No. 939) can be used if access to more than one of the Auxiliary Receptacle functions is required simultaneously. Connecting the interface to the 6-pin connector on the sampler provides three additional connectors for use. Two or more interfaces may be connected

Summary of the content on the page No. 20

Visit http: //www.hach.com


Alternative user manuals
# User manual Category Download
1 Sony User manual Indoor Furnishings 1
2 Sony XL-2000K User manual Indoor Furnishings 1
3 Sony SU-32FS2 User manual Indoor Furnishings 3
4 Sony PSS-610 User manual Indoor Furnishings 10
5 Sony HVL-LBP User manual Indoor Furnishings 8
6 Sony SU-GW1 User manual Indoor Furnishings 2
7 Sony SU-27FS2 User manual Indoor Furnishings 0
8 Sony SU-36FS2 User manual Indoor Furnishings 0
9 Sony 210 User manual Indoor Furnishings 0
10 Sony SU-27HX1 User manual Indoor Furnishings 0
11 Sony SU-36XBR8 User manual Indoor Furnishings 1
12 AB Soft Litebook Elite 2.02 User manual Indoor Furnishings 6
13 Actron Inductive Timing Light User manual Indoor Furnishings 60
14 Sony HVL-HL1 User manual Indoor Furnishings 3
15 Sony SU-43T4 User manual Indoor Furnishings 0