Enviro C-11278 user manual

User manual for the device Enviro C-11278

Device: Enviro C-11278
Category: Indoor Furnishings
Manufacturer: Enviro
Size: 1.8 MB
Added : 3/21/2013
Number of pages: 42
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Enviro C-11278. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Enviro C-11278.

For your convenience

If looking through the Enviro C-11278 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Enviro C-11278 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Enviro C-11278 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Enviro C-11278 User manual - Online PDF
Advertisement
« Page 1 of 42 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Enviro C-11278 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Enviro C-11278. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
DV42DX
B Y : S H E R W O O D I N D U S T R I E S L T D
OWNER’S MANUAL
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
WHAT TO DO IF YOU SMELL GAS
• Open windows/extinguish any open
flame.
• Do not try to light any appliance.
• Do not touch any electrical switch
or use any phone in your b

Summary of the content on the page No. 2

Safety Precautions FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION: • All ENVIRO gas-fired appliances must be installed in FOR YOUR SAFETY accordance with their instructions. Carefully read all the • Installation and service must be performed by a qualified instructions in this manual first. Consult the building authority installer, service agency or gas supplier. having jurisdiction to determine the need for a permit prior to com

Summary of the content on the page No. 3

Table of Contents Safety Precautions......................................................................................................2 Table of Contents.......................................................................................................3 Codes And Approvals..................................................................................................4 Specifications.........................................................................................................

Summary of the content on the page No. 4

Codes And Approvals DIRECT VENT ONLY: This type is identified by the prefix DV. This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system. This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) above sea level. In the USA: The appliance may be installed at higher altitudes. Please refer to your American Gas Association guidelines which state: the sea level rated input of Gas Designed App

Summary of the content on the page No. 5

Specifications INSTALLATION OPTIONS: • Parallel to a wall or placed in a corner • With a floor hearth or raised up the wall • Ducting to other rooms • Vertical or horizontal venting WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. Dimensions: 1 2 /4" 2" (57mm) 10" (52mm) (254mm) 3 28 /16" (716mm) The center of the top ducting hook-ups are 10" (254mm) from the center

Summary of the content on the page No. 6

Operating Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating. WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE. PiLot Lighting instRuctions: Hot while operating. Do not touch. Severe burns may result. Keep children, CAUTION: clothing, furniture, gasoline or other flammable vapors away. CAUTION: Do not operate this fireplace with the glass removed, crac

Summary of the content on the page No. 7

Room Air Diverter Duct Operating Instructions PiLot Light: 1. Turn off the gas to the fireplace. If not recently done, remove the glass and let the unit air out for at least five (5) minutes to clear out any gas. Turn on gas to the heater. Leak test all joints with soapy water. NEVER USE AN OPEN FLAME FOR LEAK TESTING. 2. Start the pilot by pressing the gas control knob and turning it to PILOT. While holding the gas control knob in, press the piezo ignitor several Thermocouple Thermopile

Summary of the content on the page No. 8

Operating Instructions buRneR Lighting: A) Make sure the pilot is lit. B) Turn gas control knob COUNTER CLOCKWISE to ON. C) Flip the burner switch to ON. D) Turn HI/LO knob to the desired flame height. E) Turn on all electrical power to the unit. NOTE: Check that all burner holes are lit. TO TURN GAS FIREPLACE OFF Flip switch to OFF to turn off burners only. If the fireplace is to be turned off for the season, or for Figure 6. Control Panel servicing, turn the gas shut off valve to OFF. DO

Summary of the content on the page No. 9

Maintenance And Service Routine maintenance: At least once a year, run through the following procedures to ensure the system is clean and working properly. Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not blocked by anything. The pilot flame should be blue with little or no yellow on the tips. Warning: Clearances must be sufficient to allow access for maintenance and service Warning: Failure to position the parts in accordance with this manua

Summary of the content on the page No. 10

Maintenance And Service cLeaning DecoRative suRFaces: Painted and porcelain faces should be wiped with a damp cloth periodically. If a plated face has been purchased, it should be unpacked/unwrapped carefully to avoid getting anything on the surface of the finish, including cleaners, polish and finger prints. It is important to note that fingerprints and other marks can leave a permanent stain on plated finishes. To avoid this, give the face a quick wipe with denatured alcohol on a soft clot

Summary of the content on the page No. 11

Maintenance And Service buRneR anD Fan RemovaL: 1. Remove brick liners, see steps 1 to 4 in Secondary inStallation - brick liner reMoval. 2. The control panel is held in place with a T-20 screw on each end of the panel. Remove the two (2) screws and the control panel. 3. Undo the four (4) screws holding the burner down, the andirons and grate can be removed from the burner or left on. Pull the burner to the left approximately 1” (25 mm), this is done in order to slide the venturi out of the

Summary of the content on the page No. 12

Maintenance And Service FueL conveRsion: TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY Please read and understand these instructions before installing. Warning: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result c

Summary of the content on the page No. 13

Maintenance And Service 7. Convert the SIT gas valve: a) Remove the black protection cap from the HI/LO knob by hand shown in Figure 10. 5 b) Insert a /32” or 4 mm Allen wrench into the hexagonal key-way of the screw (see Figure 11), rotate it counter-clockwise until it is free and extract it. c) Check that the screw is clean and if necessary remove dirt. Loosen Tighten d) Flip the screw (refer to Figure 12). e) Using the Allen wrench as shown in Figure 11, rotate the screw clockwise until

Summary of the content on the page No. 14

Initial Installation QUALIFIED INSTALLERS ONLY intRoDuction: This section of the owner’s manual is for the use of qualified technicians only. Fireplace placement, hearths, facings, mantels, and venting terminations will be covered, as well as the gas and electric systems. There are several installation safety guidelines that must be adhered to. Please carefully read the safety precautions at the front of this manual. PLacement: The location for the fireplace can be along a wall, raised or at

Summary of the content on the page No. 15

Initial Installation QUALIFIED INSTALLERS ONLY coRneR instaLLation: The dimensions for installing a fireplace in the corner of a room are given below in Figure 11. 7 20 /8" (530mm) 3 46 /4" 3 3 14 /4" 14 /4" (1189mm) (375mm) (375mm) 1 19 /2" (494mm) 1 42" 12 /16" (1067mm) (307mm) 1 66 /8" (1681mm) Figure 16. Dimensions for a corner installation. RaiseD FiRePLaces anD heaRths: There are a few options with raised fireplaces: raised with no hearth, raised with a raised hearth, or raised with a fl

Summary of the content on the page No. 16

Initial Installation QUALIFIED INSTALLERS ONLY If the unit is raised less than 3” (76mm) it is mandatory to have a hearth installed with Protector pad, Do not tile cement board a protector pad (sheet metal) higher than and finishing this ledge placed directly on the floor or material. hearth framing, with the cement board (see specs below) on top of it. Tile, or another non- Tile combustible material forms Cement board Protector Pad the top layer of the hearth. A Figure 19. Raised Fire

Summary of the content on the page No. 17

Initial Installation QUALIFIED INSTALLERS ONLY manteL cLeaRances: It is not necessary to install a mantel, but if one is desired it is important to follow the guidelines shown in Figure 22. The Manor face has a different set of mantel clearances than the other faces, see Figure 23. Combustibles Combustibles 8" (203mm) mantel 8" (203mm) mantel 3½" (89mm) 20" (508mm) 17" 17" 10" (432mm) 10" (432mm) (254mm) (254mm) 12" 12" (305mm) (305mm) DV42DX DV42DX with Manor Cement Board Cement Board Figure

Summary of the content on the page No. 18

Initial Installation QUALIFIED INSTALLERS ONLY Table 2: Vent termination clearances, refer to Figure 24. 1 2 Letter Canadian Installation US Installation Description A 12 in (30 cm) Clearance above grade, verandah, porch, deck, or balcony. B 12 in (30 cm) 9 in (23 cm) Clearance from window or door that may be opened. C 12 in (30 cm)* Clearance from permanently closed window (to prevent condensation). D 24 in (60 cm)* Vertical clearance to ventilated soffit located above the terminal, within

Summary of the content on the page No. 19

Initial Installation QUALIFIED INSTALLERS ONLY INSTALLATION INSTRUCTIONS: 1. Plan your installation and clearances to combustibles. Decide on a location for the unit that will meet the clearances noted in the venting section, and any or all local code requirements. 2. Set the appliance in the desired location. Determine if any wall studs, electrical wiring, or plumbing pipes are in the way of the venting system as it passes through the exterior wall. The fireplace location should be adjuste

Summary of the content on the page No. 20

Initial Installation QUALIFIED INSTALLERS ONLY 9. Install the flex pipe assembly through the wall thimble, ensure that this portion of pipe slides through the outside wall far enough to connect onto the vent termination cap. 10. Apply a bead of Mill-Pac Black sealant to the top section of the Ø4” (10 cm) by 5” (12.5 cm) flue collar adaptor previously installed into the fireplace flue outlet. Slide the Ø4” (10 cm) flex vent over the flue collar and secure with three (3) sheet metal screws ev


Alternative user manuals
# User manual Category Download
1 Enviro 50-645 User manual Indoor Furnishings 0
2 Enviro Cara DR C-11500 User manual Indoor Furnishings 0
3 Enviro C-10078 User manual Indoor Furnishings 0
4 Sony User manual Indoor Furnishings 1
5 Sony XL-2000K User manual Indoor Furnishings 1
6 Sony SU-32FS2 User manual Indoor Furnishings 3
7 Sony PSS-610 User manual Indoor Furnishings 10
8 Sony HVL-LBP User manual Indoor Furnishings 8
9 Sony SU-GW1 User manual Indoor Furnishings 2
10 Sony SU-27FS2 User manual Indoor Furnishings 0
11 Sony SU-36FS2 User manual Indoor Furnishings 0
12 Sony 210 User manual Indoor Furnishings 0
13 Sony SU-27HX1 User manual Indoor Furnishings 0
14 Sony SU-36XBR8 User manual Indoor Furnishings 1
15 AB Soft Litebook Elite 2.02 User manual Indoor Furnishings 6