Elation Professional DMX 101 user manual

User manual for the device Elation Professional DMX 101

Device: Elation Professional DMX 101
Category: Indoor Furnishings
Manufacturer: Elation Professional
Size: 0.96 MB
Added : 4/18/2014
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Elation Professional DMX 101. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Elation Professional DMX 101.

For your convenience

If looking through the Elation Professional DMX 101 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Elation Professional DMX 101 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Elation Professional DMX 101 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Elation Professional DMX 101 User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Elation Professional DMX 101 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Elation Professional DMX 101. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


DMX 101:
A DMX 512 HANDBOOK

Summary of the content on the page No. 2

DMX 101: A DMX 512 Handbook Handbook Revision: May 2008 2 Elation Professional ®

Summary of the content on the page No. 3

Table of Contents 1. Introduction to DMX ...................................................................................................................................... 4 2. Industry Standards .......................................................................................................................................... 5 2.1 USITT .....................................................................................................................................................

Summary of the content on the page No. 4

DMX 101: A DMX 512 Handbook 1. Introduction to DMX This handbook is designed to promote basic understanding of the DMX 512 protocol, including theory of operation, proper equipment use, and some basic application examples. DMX is an acronym for Digital Multiplex, a communication protocol (a set of rules) used to remotely control lighting dimmers and intelligent fixtures. It is designed to provide a common communications standard between these lighting devices regardless of the manufacturer.

Summary of the content on the page No. 5

2. Industry Standards About 20 years ago, most manufacturers used their own, proprietary control protocols. This forced system designers to use only fixtures and control consoles from the same manufacturer. There was no control standard to allow the use of different products. A standard is a set of widely agreed-upon guidelines for interoperability at both communications and mechanical levels. Standardization of protocol and equipment provides many benefits to manufacturers and end users

Summary of the content on the page No. 6

DMX 101: A DMX 512 Handbook 2.3 ANSI The American National Standards Institute (ANSI) is an organization composed of representatives from industry and government that collectively determine standards for the electronics industry as well as many other fields, such as chemical and nuclear engineering, health and safety, and construction. ANSI also represents the United States in setting international standards. New electronic equipment and methods must undergo extensive testing to obtain AN

Summary of the content on the page No. 7

3. Theory of Operation DMX 512 is an asynchronous serial digital data protocol. While that might mean something to an engineer, most people are not familiar with how all this techno-gibberish actually accomplishes lighting control. This section will attempt to explain how DMX operates in a simplified and easy-to-understand manner. The topics this section will cover are: • The Cable TV Analogy • DMX Communications 3 www.elationlighting.com 7

Summary of the content on the page No. 8

DMX 101: A DMX 512 Handbook 3.1 The Cable TV Analogy A central concept of DMX 512 is the ability to transmit data on multiple channels over a single cable. To better understand this concept, imagine a simple cable TV system (Figure 1) with four major components: • Cable TV Company • Cable • Decoder • TV 3 Figure 1 The Cable TV Company broadcasts many channels at once in a mixed signal over a single cable. The Cable carries the signal to a Decoder, usually a cable TV box or similar device.

Summary of the content on the page No. 9

Now imagine a simple DMX system (Figure 2), where: • The Cable TV Company is the DMX Control Console • The Cable is the DMX Cable • The Decoder is the DMX Decoder (built into a Dimmer) • The TV is the Lighting Fixture 3 Figure 2 The DMX Control Console will broadcast up to 512 channels over one DMX Cable. Some of these channels may not be used, but will still be transmitted, as required by the protocol. The Decoder in this example is built into the Dimmer. It must be set to a desired channe

Summary of the content on the page No. 10

DMX 101: A DMX 512 Handbook Many DMX devices (such as dimmers and intelligent fixtures) are capable of receiving several control channels at once. If a Dimmer has four channels capable of controlling four Light Fixtures (Figure 3), it must know which four control channels to receive. This is accomplished by setting a ‘base address’, or the DMX address for the first Light Fixture (channel 005, in this example). The remaining Light Fixtures will be controlled by the next three sequential c

Summary of the content on the page No. 11

3.2 DMX Communications In the world of digital communications, information is sent using precise electrical voltage pulses. A positive voltage pulse represents a 1. A zero voltage pulse (or no voltage) represents a 0. Systems using 1’s and 0’s to encode information are called binary systems. Each pulse in a digital signal is called a binary digit, or bit. A bit can only have one of two values, 1 or 0. A grouping of eight bits, called a byte, is used to carry one piece of information. Th

Summary of the content on the page No. 12

DMX 101: A DMX 512 Handbook While 4000 feet may be specified by the standard, most manufacturers recommend DMX runs of no more than 1000 feet (300 feet between devices) before using a repeater to regenerate the signal. Each device should have input and output connectors, but these are usually wired together. No re-transmission or amplification is performed. Devices are connected in a daisy-chain fashion, from the controller to device #1, then device #1 to device #2, and so on. The final

Summary of the content on the page No. 13

3.3 Summary So how does all this information relate to controlling a light fixture? Think of it in terms of the simple DMX Controller Console (Figure 4). The console may have up to 512 control faders on it (8 in this example). Each fader controls the intensity of one light (using one DMX Channel). The position of the fader represents an 8-bit value (DMX Value) between 0 and 255, where 0 is off and 255 is full on. Up to 32 devices may be connected in a daisy-chain, with a terminator on the

Summary of the content on the page No. 14

DMX 101: A DMX 512 Handbook 4. Protocol Specifications Understanding how DMX 512 operates is important, but it’s only part of the picture. The physical equipment, connectors and cabling, play a critical role in the proper functionality of the protocol. The DMX standard specifies exactly what types of connectors and cable may be used. It is also important to understand the logic behind the data that is transmitted. Data is sent in a specific manner so that the receiver can correctly transl

Summary of the content on the page No. 15

4.1 Connectors The DMX standard specifies 5-pin XLR connectors (Figure 5). The name comes from the original manufacturer (Cannon X connector, with a Latch and Rubber guard). Only three of these pins have standardized use however, leading many companies to make use of inexpensive and readily available 3-pin XLR connectors (Figure 6). The remaining two pins are in place for future use, such as allowing connected devices to communicate information back to the controller (lamp hours, operatin

Summary of the content on the page No. 16

DMX 101: A DMX 512 Handbook 4.2 Cabling Standard DMX 512 requires twisted-pair, shielded, low-capacitance data cable (Figure 7) designed for RS-485 (such as ACCU-Cable from Elation). The twisted-pair configuration ensures that any interference affects both signals equally. This practice is common to good data cable, helping the signal driver eliminate any interference. The cable shield also protects against interference. A shield ‘drain’ wire makes connector installation easier. OUTER IN

Summary of the content on the page No. 17

4.3 Data DMX 512 data is transmitted at 250 kiloHertz (kHz), meaning that 250,000 1’s and 0’s (at a maximum) can be sent each second. Each bit is measured in 4 microsecond (µs) intervals. In order for the receiving device to correctly interpret the data, it must be sent in a particular sequence. A single transmission (DMX Packet) includes synchronizing elements and channel data for up to 512 channels (Figure 8). Figure 8 The following table describes each element of the DM

Summary of the content on the page No. 18

DMX 101: A DMX 512 Handbook 5. Sample Applications The figures on the following pages illustrate several different applications using various DMX products. Samples include: • Dimmer Control • Intelligent Fixture Control • Dimmer & Intelligent Fixture Control • Distributed Control As mentioned earlier, dimmers normally use one DMX Channel per light. They translate DMX Values in a linear fashion, with 0 being off and 255 full on. Intelligent fixtures use one DMX Channel per parameter (such

Summary of the content on the page No. 19

5.1 Dimmer Control 5 www.elationlighting.com 19

Summary of the content on the page No. 20

DMX 101: A DMX 512 Handbook 5.2 Intelligent Fixture Control 5 20 Elation Professional ®


Alternative user manuals
# User manual Category Download
1 Elation Professional CMY Zoom 575 User manual Indoor Furnishings 0
2 Elation Professional LUM013 User manual Indoor Furnishings 0
3 Elation Professional Opti RGB User manual Indoor Furnishings 1
4 Elation Professional Rayzor Q7 User manual Indoor Furnishings 0
5 Elation Professional ELAR 108 PAR RGBW User manual Indoor Furnishings 1
6 Elation Professional User manual Indoor Furnishings 1
7 Elation Professional Elair Tri Brick User manual Indoor Furnishings 2
8 Elation Professional ETP554 User manual Indoor Furnishings 1
9 Elation Professional Power Wash 575E User manual Indoor Furnishings 2
10 Elation Professional 216 User manual Indoor Furnishings 1
11 Sony User manual Indoor Furnishings 1
12 Sony XL-2000K User manual Indoor Furnishings 1
13 Sony SU-32FS2 User manual Indoor Furnishings 3
14 Sony PSS-610 User manual Indoor Furnishings 10
15 Sony HVL-LBP User manual Indoor Furnishings 8