Desa Motion Sensor Light Control 5412 user manual

User manual for the device Desa Motion Sensor Light Control 5412

Device: Desa Motion Sensor Light Control 5412
Category: Indoor Furnishings
Manufacturer: Desa
Size: 0.35 MB
Added : 11/23/2014
Number of pages: 8
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Desa Motion Sensor Light Control 5412. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Desa Motion Sensor Light Control 5412.

For your convenience

If looking through the Desa Motion Sensor Light Control 5412 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Desa Motion Sensor Light Control 5412 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Desa Motion Sensor Light Control 5412 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Desa Motion Sensor Light Control 5412 User manual - Online PDF
Advertisement
« Page 1 of 8 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Desa Motion Sensor Light Control 5412 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Desa Motion Sensor Light Control 5412. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

OPERATION
®
Mode: On-Time Works: Day Night
Test 5 Seconds x x
Auto 1, 5, or 10 Minutes x
Motion Sensor Light
Manual To Dawn* x
* resets to Auto Mode at dawn.
Control
1
Note: When fi rst turned on wait about 1 /2 minutes for
Model 5412
the circuitry to calibrate.
TEST
Features
� Turns on lighting when motion is detected.
ON-TIME
Put the ON-TIME switch on the bottom
� Automatically turns lighting off.
of the sensor in the TEST position.
� Photocell keeps the lighting off during daylight
10 5

Summary of the content on the page No. 2

❒ Twist the junction box wires and fi xture wires together INSTALLATION as shown. Secure with wire connectors. For easy installation, select an existing light with a wall Mounting White to switch for replacement. Black to Strap White Black Rubber Plug Wall Mount Eave Mount Mounting Bolt For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock. Gasket For eave mount only: Junction box ground

Summary of the content on the page No. 3

❒ Loosen the clamp screw in the Clamp TEST AND ADJUSTMENT sensor ball joint and gently Screw ❒ Turn on the circuit breaker and light switch. rotate the sensor. Ball ❒ Walk through the coverage 1 Joint NOTE: Sensor has a 1 /2 minute warm up period area noting where you are before it will detect motion. When fi rst turned when the lights turn on (also, 1 on, wait 1 /2 minutes. the LED will fl ash several times when motion is detected). Move ❒ Turn the RANGE control to the mid position and

Summary of the content on the page No. 4

TROUBLESHOOTING GUIDE SYMPTOM POSSIBLE CAUSE SYMPTOM POSSIBLE CAUSE Lights will not come 1. Light switch is turned off. Lights stay on 1. A fl ood lamp is positioned too close to on. 2. Flood light is loose or continuously. the sensor or pointed at nearby objects burned out. that cause heat to trigger the sensor. 3. Fuse is blown or circuit breaker (Reposition the lamp away from the is turned off. sensor or nearby objects). 4. Daylight turn-off is in effect (re- 2. Light Control is pointed to

Summary of the content on the page No. 5

FUNCIONAMIENTO ® Modalidad: A tiempo: Trabaja: Día Noche Prueba 5 seg. x x Control de luz del Autom. 1, 5, ó 10 min. x detector de movimiento Manual Hasta el x amanecer* Modelo 5412 *Se pone en Automático al amanecer. Características 1 Nota: Cuando lo prenda por primera vez espere 1 / 2 � Prende la luz cuando detecta movimiento. minutos para que el circuito se claibre. � Apaga la luz automáticamente. � La fotocélula mantiene la luz apagada durante el día. Para PRUEBA: � LED indica que se ha de

Summary of the content on the page No. 6

❒ Conecte los cables de la caja de empalme con los INSTALACION cables del aparato de luz, como se muestra. Tuérazalos Para una fácil instalación escoja una luz con un juntos y asegúrelos con un conector de cables. interruptor de pared. Negro a Blanco a Blanco lámina de Negro Empaquetadura Montaje Enchufe de Caucho Perno de Montaje Montaje en pared Montaje en alero Para instalarlo bajo el alero, la cabeza del detec- tor debe ser girada como se muestra en los dos Cable de a tierra de la

Summary of the content on the page No. 7

❒ Afl oje el tornillo sujetador en la Tornillo PRUEBA Y AJUSTE unión esférica y gire despacio Sujetador ❒ Prenda el cortacircuitos y el interruptor de luz. el detector. Unión ❒ Camine por el área a prote- 1 NOTA: El detector tiene un período de cerca de 1 / 2 Esférica gerse y dése cuenta dónde minutos de calentamiento antes de detectar está cuando se prende la luz. movimiento. Cuando lo prenda por primera Mueva la cabeza del detec- 1 vez, espere 1 / minutos. 2 tor hacia arriba, hacia ab

Summary of the content on the page No. 8

GUIA DE INVESTIGACION DE AVERIAS SINTOMA POSIBLE CAUSA SINTOMA POSIBLE CAUSA La Luz no se enci- 1. El interruptor de luz está apaga- La luz se 1. Un faro está colocado demasiado cerca ende. do. queda al detector o apunta a objetos cercanos 2. El faro está fl ojo o fundido. prendida que hace que el calor active el detec- 3. El fusible está quemado o el continuamente. tor. (Reposicione la lámpara lejos del cortacircuitos está apagado. detector o de los objetos cercanos). 4. La desconexión de luz


Alternative user manuals
# User manual Category Download
1 Desa Motion Sensing Halogen Fixture 5525 User manual Indoor Furnishings 2
2 Sony User manual Indoor Furnishings 1
3 Sony XL-2000K User manual Indoor Furnishings 1
4 Sony SU-32FS2 User manual Indoor Furnishings 3
5 Sony PSS-610 User manual Indoor Furnishings 10
6 Sony HVL-LBP User manual Indoor Furnishings 8
7 Sony SU-GW1 User manual Indoor Furnishings 2
8 Sony SU-27FS2 User manual Indoor Furnishings 0
9 Sony SU-36FS2 User manual Indoor Furnishings 0
10 Sony 210 User manual Indoor Furnishings 0
11 Sony SU-27HX1 User manual Indoor Furnishings 0
12 Sony SU-36XBR8 User manual Indoor Furnishings 1
13 AB Soft Litebook Elite 2.02 User manual Indoor Furnishings 6
14 Actron Inductive Timing Light User manual Indoor Furnishings 60
15 Sony HVL-HL1 User manual Indoor Furnishings 3