Summary of the content on the page No. 1
Crestron CLS-C6RF
™
iLux Integrated Lighting System
™
w/infiNET
Operations Guide
Summary of the content on the page No. 2
This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand names, product names and trademarks are the property of their respective owners. ©2008 Crestron Electronics, Inc.
Summary of the content on the page No. 3
™ ™ Crestron CLS-C6RF iLux Integrated Lighting System w/infiNET Contents ™ ™ iLux Integrated Lighting System w/infiNET : CLS-C6RF 1 Introduction ...............................................................................................................................1 Features and Functions................................................................................................1 Specifications ......................................................................................
Summary of the content on the page No. 4
Summary of the content on the page No. 5
™ ™ Crestron CLS-C6RF iLux Integrated Lighting System w/infiNET ™ iLux Integrated Lighting System ™ w/infiNET : CLS-C6RF Introduction Features and Functions • Wall-mounted integrated lighting and shade control • Six channels of dimming or switching • Six groups of shade or drape control • Linkable for up to 54 lighting channels and 54 shade groups • Up to 16 user-settable scenes | Large ON and OFF buttons • Seven configurable “rocker” buttons with customizable label strip
Summary of the content on the page No. 6
™ ™ iLux Integrated Lighting System w/infiNET Crestron CLS-C6RF designed for 120 VAC 50/60 Hz installations; the CLSI-C6RF and CLSI-C6MRF are designed for 230 VAC 50/60 Hz installations. The units are functionally identical, except that the CLS/CLSI-C6MRF units include a built-in motion sensor. For simplicity in this guide, references to the CLS-C6RF unit apply equally to all, except where noted. Six Channel Dimming The CLS-C6RF features six channels of dimming for incandescent, magnetic
Summary of the content on the page No. 7
™ ™ Crestron CLS-C6RF iLux Integrated Lighting System w/infiNET Multi-Unit Expansion A single CLS-C6RF master will support up to eight additional units, enabling systems of up to 54 lighting zones and 54 shade groups. Scene recall, master dimming, and occupancy status are shared between the units. Each individual unit can still support a complete assortment of local devices including keypads, shade controllers, and sensors. ™ Control System Integration via infiNET The CLS-C6RF employs Cr
Summary of the content on the page No. 8
™ ™ iLux Integrated Lighting System w/infiNET Crestron CLS-C6RF CLS-C6RF Specifications (Continued) DETAILS SPECIFICATION Power Requirements CLS-C6RF Line Power, 100 –127 VAC, 50 / 60Hz CLSI-C6RF Line Power, 220 – 240 VAC, 50 / 60Hz Default MNET ID 1F 2, 3 Control System Update Files 2-Series Control System Version 2.004.CUZ or later IR Receiver Reception Frequency 36 kHz Requires Crestron IR remote (sold separately). RF Wireless RF Transceiver 2-way RF, 2.4 GHz ISM Channels
Summary of the content on the page No. 9
™ ™ Crestron CLS-C6RF iLux Integrated Lighting System w/infiNET NOTE: Crestron software and any files on the website are for Authorized Crestron dealers and Crestron Authorized Independent Programmers (CAIP) only. New users may be required to register to obtain access to certain areas of the site (including the FTP site). Physical Description All controls and indicators for the CLS-C6RF are located on the front of the unit. The front panel also contains a mini phone jack, under the flip-up
Summary of the content on the page No. 10
™ ™ iLux Integrated Lighting System w/infiNET Crestron CLS-C6RF CLS-C6RF Front Panel CLS-C6RF Rear Panel Connectors, Controls, & Indicators # CONNECTORS, DESCRIPTION CONTROLS, & INDICATORS 1 Bargraphs In Standard mode and Lights mode, the bargraphs, each a series of seven LEDs, indicate the current light intensity for the six lighting loads. In Shades mode, they indicate the shade position for each of the shade groups. The bargraphs have other functions in Setup mode. 2 Labe
Summary of the content on the page No. 11
™ ™ Crestron CLS-C6RF iLux Integrated Lighting System w/infiNET Connectors, Controls, & Indicators (Continued) # CONNECTORS, DESCRIPTION CONTROLS, & INDICATORS 5 Motion Detector (CLS/CLSI- The built-in motion detector can be used to activate C6MRF only) a particular scene when there is activity in the room, and/or to activate a particular scene (typically Off) when there is no activity for a specified period. A limited number of actions are available when programmed locally; more are a
Summary of the content on the page No. 12
™ ™ iLux Integrated Lighting System w/infiNET Crestron CLS-C6RF Connectors, Controls, & Indicators (Continued) # CONNECTORS, DESCRIPTION DESCRIPTION CO CONTR NTRO OLS, LS, & & IN IND DI ICA CATORS TORS 16 LOAD1 – LOAD6 Use these terminals to connect the CLS-C6RF dimmer channel outputs to the appropriate lighting loads. 17 HOT, NEUTRAL, ((Ground) Use these terminals to connect the unit to the 120V (CLS-C6RF/MRF) or 230V (CLSI-C6RF/MRF) AC power source. 18 NOT USED This 4-pin ter
Summary of the content on the page No. 13
™ ™ Crestron CLS-C6RF iLux Integrated Lighting System w/infiNET Setup Network Wiring When wiring the network, consider the following: • Use Crestron Certified Wire. • Use Crestron power supplies for Crestron equipment. • Provide sufficient power to the system. CAUTION: Insufficient power can lead to unpredictable results or damage to the equipment. Please use the Crestron Power Calculator to help calculate how much power is needed for the system (http://www.crestron.com/calculators).
Summary of the content on the page No. 14
™ ™ iLux Integrated Lighting System w/infiNET Crestron CLS-C6RF CLS-C6RF Installation Configurations * Refer to “Appendix A: Supported Devices” on page 42 for details on devices supported by the CLS-C6RF. ™ ™ 10 • iLux Integrated Lighting System w/infiNET : CLS-C6RF Operations Guide - DOC. 6418A
Summary of the content on the page No. 15
™ ™ Crestron CLS-C6RF iLux Integrated Lighting System w/infiNET Hardware Hookup Refer to the following diagram for connection of the AC wiring. Connect each load wire to the corresponding LOAD terminals on the unit, connect the power line hot wire from the circuit breaker to the HOT terminal on the unit, connect all neutral wires to the NEUTRAL terminal on the unit, and connect all ground wires to the (ground) terminal on the unit. For details, refer to the iLux Lighting System Installat
Summary of the content on the page No. 16
™ ™ iLux Integrated Lighting System w/infiNET Crestron CLS-C6RF Configuring the CLS-C6RF The overall configuration of the CLS-C6RF can be accomplished in two ways: using ™ the front panel controls, or using the supplied iLux Designer application software, which can be downloaded from the Crestron website. Configuring via the front panel controls is not as extensive as what can be done using the iLux Designer, but permits basic functional setup without having to use a PC. In addition, so
Summary of the content on the page No. 17
™ ™ Crestron CLS-C6RF iLux Integrated Lighting System w/infiNET 4. If you would like a certain lighting load to be unaffected by that scene recall, press and hold the center of the button (so both sides make contact) for three seconds. The top two and the bottom two LEDs of the associated bargraph will be lit (and the display will show - -) to indicate that the level of the lighting load will not change when that scene is recalled. 5. To change the shade presets for that scene press the Sh
Summary of the content on the page No. 18
™ ™ iLux Integrated Lighting System w/infiNET Crestron CLS-C6RF Setup Mode Mnemonics TWO-DIGIT DESCRIPTION DISPLAY Sc Scene Programming Ld Setup lighting load Load types LE Setup lighting load Low-End limits HE Setup lighting load High-End limits bF button Functions (i.e. recall scene, toggle scene, shades control, etc.) ud Set function of up/down button oc Setup occupancy Sensing Ad Run Auto-discovery AS Assign Shade groups id Display or set the MNET id of this unit Ac Acquire ga
Summary of the content on the page No. 19
™ ™ Crestron CLS-C6RF iLux Integrated Lighting System w/infiNET • If a lighting load is defined as an “unused” load type, the bargraph for that lighting load will have all LEDs off. If you try to adjust that lighting load, the two-digit display will show “Er.” • To mark a lighting load as "not affected" (i.e., the lighting load’s current state will not be changed by recalling the scene), press and hold the center of the corresponding button for three seconds. Adjustments made to such light
Summary of the content on the page No. 20
™ ™ iLux Integrated Lighting System w/infiNET Crestron CLS-C6RF Lighting Load Type Setup (Continued) Load Type Number LEDs Default LowEnd / HighEnd Fluorescent (2-wire) 4 top 4 on 10 / 100 Non-dim (On at start/Off at start)¹ 5 top 5 on 0 / 100 Non-dim (On at end/Off at start)² 6 top 6 on 0 / 100 1. Whether going on or off, this load type will switch at the start of the fade. 2. If going off, this load type will switch at the start of the fade; if going on, it will switch at the end. NO