Summary of the content on the page No. 1
ProTron LED
USER MANUAL
Version 2.0 24-004-3533-00
Summary of the content on the page No. 2
ProTron LED TABLE OF CONTENTS TABLE OF CONTENTS PREFACE ........................................................................................................................................ About this Manual 3 .............................................................................................................................................. Included Items 3 ...............................................................................................................................
Summary of the content on the page No. 3
ProTron LED PREFACE 1. About this Manual The document provides installation and operation instructions for the following products: ProT ron LED Luminaire Please read all instructions before installing or using this product. Retain thi s manual f or futur e r efer enc e. Additional product information and descriptions may be found on the product specification sheet. Note: The ProTron LED Luminaire is universal voltage 100 to 240 VAC (auto-ranging). 2. Included Items Each ProTron LED Luminaire
Summary of the content on the page No. 4
ProTron LED ProTron LED LUMINAIRE OVERVIEW 1. ProTron LED Luminaire Components Major Luminaire Components Yoke Assembly AC Output AC Input DMX512 / DMX512 / RDM Input RDM Output High Intensity LED Array Truss Hook / Clamp* Attachment Point Luminaire Head Assembly Yoke(Tilt) Position Locking handle Safety cable anchor point Figure 1: ProTron LED Luminaire Components 4
Summary of the content on the page No. 5
ProTron LED LCD Display / Menu System EXIT Button CHECK MARK(OK) Button RIGHT Arrow Button LEFT Arrow Button Figure 2: LCD Display & Menu System Note: For Menu operation and programming details, refer to "LCD Display and Menu System" on page 9 . 5
Summary of the content on the page No. 6
ProTron LED INSTALLATION AND SET UP 1. Power Requirements The ProTron LED Luminaire operates on AC input voltages from 100 to 240 VAC. WARNING! This unit does not contain an ON/OFF switch. Always disconnect power input cable to completely remove power from unit when not in use. Note: The ProTron LED Luminaires has to be cooled down for 20min after it continuously works for 30 minutes. Keep working continuously will do great harm to the luminaire. Or there will be an power reduction functio
Summary of the content on the page No. 7
ProTron LED Table 2: ProTron LED Luminaire (IP65 Rated Models) AC Input Connections Back of Unit AC Input AC Output Figure 3: ProTron LED Luminaire AC Input & Output Connections CAUTION: In the event the AC input cable of this luminaire is damaged, it must be replaced, by the user, with an approved cable through an Authorized Dealer or Service Center. 3. Connecting to the DMX512 Network Basic DMX512 installation consists of connecting multiple ProTron LED Luminaires together (up to 32 luminai
Summary of the content on the page No. 8
ProTron LED Luminaires ProTron LED DMX512 ( fr om console or contr o l device) DMX512 (out to the next DMX512 ( o ut fr om fir st lu minair e or DMX512 to second luminair e) contr o lled device) Figure 5: ProTron LED Luminaire - DMX512 Connections 4. Mounting Luminaire The ProTron LED Luminaires are designed to sit directly on its yoke assembly in a floor installation application. When used in this type of application, loosen the locking handle securing the innerportion of the yoke assembl
Summary of the content on the page No. 9
ProTron LED OPERATION AND PROGRAMMING 1. LCD Display and Menu System The ProTron LED Luminaire’s LCD Display and Menu System provides local control for accessing the following fixture’s settings: Presets (Standard and User Defined) Fixture Settings Effects(Chases - preloaded and user defined) Current Fixture Operational Status Setting the DMX512 Address Note: If there are multiple luminaires in a system, changes would need to be made at each LCD Menu as desired. Upon power up, the LCD will di
Summary of the content on the page No. 10
ProTron LED 3. Press CHECK MARK(OK)button to access Preset Select. ..Preset Edit 1. Intensity Use LEFT and RIGHT arrow buttons to scroll through all presets and select Preset x(0 thru 31). Press CHECK MARK(OK)button to select the desired menu among Intensity, Strobe Rate, Duration and Effects, Zone1, Zone2, Zone3 and Zone4. Once at desired preset, use LEFT and RIGHT arrow buttons to adjust parameter value as desired. Once all values are adjusted as desired, press CHECK MARK(OK)button. Save
Summary of the content on the page No. 11
ProTron LED 4. ProTron LED Luminaire Menu Tree Figure 8: ProTron LED Luminaire Menu Tree 11
Summary of the content on the page No. 12
ProTron LED 5. Dimming Curve Selection Through the menu, you are able to select one of four dimming curves: Linear Curve PL_Curve S_Curve Square Curve Linear Curve PL_Curve * 0 0 DMX Value DMX Value *PL Curve follows the dimming curve of Philips Selecon PL series LED luminaries. S_Curve Square Curve 0 0 DMX Value DMX Value Figure 9: ProTron LED Luminaire Dimmer Curves 12 Lumen Output Lumen Output Lumen Output Lumen Output
Summary of the content on the page No. 13
ProTron LED 6. Master / Slave Operational Mode The Master / Slave Operational Mode allows one ProTron LED Luminaire to act as the "Master" unit and all other connected units are controlled by this unit. When a unit is set to "Slave" mode, it will only listen to and follow any commands sent from a "Master" unit. Only one "Master" unit is allowed in this type of operation. To setup a master / slave network: Step 1. Set the first device in the DMX512 chain to Master Mode through the unit’s m
Summary of the content on the page No. 14
ProTron LED DMX CONTROL This section contains information for operating the luminaire using DMX control in Single Channel, Three Channel, Four Channel, 16-bit Control and Zone Mapping modes. For Menu options and detailed information, see "LCD Display and Menu System" on page 9. Note: These tables assume a DMX start address of 1. When a different starting address is used, this address becomes channel 1 function and other functions follow in sequence. 1. Single Channel Mode Table 3 provides DM
Summary of the content on the page No. 15
ProTron LED 3. Four Channel Mode Table 5 provides DMX channel mapping of all DMX512 control values when the ProTron LED Luminaire is in Four Channel mode (as set by the luminaire’s menu system). Table 5: ProTron LED Luminaire DMX Channel Mapping (Four Channel Mode) 8 bit control for Intensity of LED settings. 1 Intensity Strobe's duration,Range is 0-255 2 Strobe Duration White light mode (when strobe rate is also at 255) Please refer to the Strobe Duration Detail. Strobe rate slow to fast. 3
Summary of the content on the page No. 16
ProTron LED 4. 16-Bit Mode Table 6 provides DMX channel mapping of all DMX512 control values when the ProTron LED Luminaire is in 16-Bit Mode (as set by the luminaire’s menu system). Table 6: ProTron LED Luminaire DMX Channel Mapping (16-Bit Control Mode) 0-100% Instensity High 0-65535 1 0 16 bit control for Intensity of LED settings. 2 Instensity Low 0-255 0-100% Controls strobe operations as follows . . . No Effect = DMX 0 - 5 Ramp Up
Summary of the content on the page No. 17
Pr ProT oTr ron LED on LED 5. Custom Mode Table 7 provides DMX channel mapping of all DMX512 control values when the ProTron LED Luminaire is in Custom Mode (as set by the luminaire’s menu system). Table 7: ProTron LED Luminaire DMX Channel Mapping (Custom Mode) 17
Summary of the content on the page No. 18
ProTron LED 6. Zone Mapping Mode Table 8 provides DMX channel mapping of all DMX512 control values when the ProTron LED Luminaire is in Zone mapping Mode (as set by the luminaire’s menu system). Table 8: ProTron LED Luminaire DMX Channel Mapping (Zone Mapping Mode) Master Intensity Hight 1 0 - 65535 0 - 100% 0 16 bit control for Intensity of LED settings. Master Intensity Low 2 Effects 3 0 - 255 0 - 100% 0 Effects.(refer to the Effects detail) Control Channel 4 0 - 255 0 - 100% 0 Control Chan
Summary of the content on the page No. 19
ProTron LED Table 11: ProTron LED Luminaire RDM Parameters IDs Get Set RDM Parameter IDs Value Comment Implemented Allowed Allowed Category - Network Management DISC_UNIQUE_BRANCH 0x0001 ■ DISC_MUTE 0x0002 ■ DISC_UN_MUTE 0x0003 ■ PROXIED_DEVICES 0x0010 ■ PROXIED_DEVICES_COUNT 0x0011 ■ COMMS_STATUS 0x0015 ■ ■ Category - Status Collection QUEUED_MESSAGE 0x0020 ■ ■ STATUS_MESSAGES 0x0030 ■ ■ STATUS_ID_DESCRIPTION 0x0031 ■ ■ CLEAR_STATUS_ID 0x0032 ■ ■ SUB_DEVICE_STATUS_REPORT_THRESHOLD 0x0033 ■ ■ C
Summary of the content on the page No. 20
ProTron LED Table 11: ProTron LED Luminaire RDM Parameters IDs Get Set RDM Parameter IDs Value Comment Implemented Allowed Allowed ■ RECORD_SENSORS 0x0202 Category - Dimmer Settings 0x03xx - FUTURE USE Category - Power / Lamp Settings 0x04xx ■ ■ DEVICE_HOURS 0x0400 ■ ■ LAMP_HOURS 0x0401 ■ ■ LAMP_STRIKES 0x0402 ■ ■ LAMP_STATE 0x0403 ■ ■ LAMP_ON_MODE 0x0404 ■ ■ DEVICE_POWER_CYCLES 0x0405 Category - Display Settings 0x05xx ■ ■ DISPLAY_INVERT 0x0500 ■ ■ ■ DISPLAY_LEVEL 0x0501 Category - Configurati